Introduction

Dry Bath Incubator has temperature range of RT+5 to 110℃. It features four independent timing groups for parallel or individual sample heating operations. Equipped with clear LCD screen and intuitive interface, it allows simple monitoring and parameter adjustments. Incorporates blue transparent lid that prevents splashing while allowing quick visibility. Incubator is ideal for heating, incubation, preservation, and reaction of biological and biochemical samples.

Manufactured under strict quality control processes, complying with international laboratory equipment standards. Provides 1-year warranty for main components and lifetime technical support.

Applications

Dry Bath Incubator ensures heating, incubation, preservation, and reaction of various biological and biochemical samples in research, clinical diagnostics, pharmaceuticals, food testing, and environmental laboratories.

Specifications

Temperature Setting Range 0 to 110℃
Temperature Control Range RT+5 to 110℃
Block Quantity 4
Temperature Accuracy Less than or equal to ±0.3℃ at 37℃
Temperature Uniformity Less than or equal to ±0.3℃ at 37℃
Heating Time Less than or equal to 20min (from 25℃ to 110℃)
Time Range 1min to 99h59min/∞
Auto Running Yes
Auto Heating Yes
Auto Resume Yes
Independent Timing Yes
Display Accuracy 0.1℃
Fuse 250V 3A Ф5×20
Power Consumption 500W
Power Supply AC220V or AC110V, 50/60Hz
Dimensions 370×254×228 mm
Weight 8 Kg

Features

Microprocessor control

Equipped with RS232/USB communication interface for data export and remote control. Supports connection to laboratory information management system (LIMS) for centralized data management and traceability.

High stability

Overheating protection

Consistent heating

Effortless setup

Model No.

Accessory

style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;height:17.5pt;padding:0cm 5.4pt;width:220.5pt;">

6mm×48 Block

style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;height:26.0pt;padding:0cm 5.4pt;width:220.5pt;">

7mm×48 Block

style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;height:26.0pt;padding:0cm 5.4pt;width:220.5pt;">

10mm×24 Block

style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;height:26.0pt;padding:0cm 5.4pt;width:220.5pt;">

12mm×24 Block

style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;height:26.0pt;padding:0cm 5.4pt;width:220.5pt;">

13mm×24 Block

style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;height:26.0pt;padding:0cm 5.4pt;width:220.5pt;">

15mm×16 Block

style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;height:26.0pt;padding:0cm 5.4pt;width:220.5pt;">

16mm×16 Block

style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;height:26.0pt;padding:0cm 5.4pt;width:220.5pt;">

19mm×12 Block

style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;height:26.0pt;padding:0cm 5.4pt;width:220.5pt;">

20mm×12 Block

style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;height:26.0pt;padding:0cm 5.4pt;width:220.5pt;">

26mm×8 Block

style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;height:26.0pt;padding:0cm 5.4pt;width:220.5pt;">

28mm×4 Block

style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;height:26.0pt;padding:0cm 5.4pt;width:220.5pt;">

40mm×3 Block

style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;height:26.0pt;padding:0cm 5.4pt;width:220.5pt;">

0.2ml×48 Block

style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;height:26.0pt;padding:0cm 5.4pt;width:220.5pt;">

0.5ml×48 Block

style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;height:26.0pt;padding:0cm 5.4pt;width:220.5pt;">

1.5ml×24 Block

style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;height:26.0pt;padding:0cm 5.4pt;width:220.5pt;">

2.0ml×24 Block

style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;height:26.0pt;padding:0cm 5.4pt;width:220.5pt;">

0.2ml×96 PCR plate

style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;height:26.0pt;padding:0cm 5.4pt;width:220.5pt;">

0.2ml×96 ELISA plate 

FAQs

1. What is a Dry Bath Incubator?

A Dry Bath Incubator is an apparatus that uses a solid, heated metal block to incubate samples at precise temperatures.

2. Can Dry Bath Incubator be used for DNA extraction?

It is commonly used for DNA extraction steps such as lysis, protein digestion, and enzyme incubation at controlled temperatures.

3. How is Dry Bath Incubator used in clinical diagnostics?

In clinical labs, it is used to incubate blood, serum, or plasma samples for enzyme assays, coagulation studies, and biochemical tests.

4. Can Dry Bath Incubator be used for enzyme inactivation?

It is frequently used to inactivate enzymes by maintaining high temperatures for a defined period.

5. Is Dry Bath Incubator suitable for thawing frozen samples?

It can quickly and uniformly thaw frozen biological samples like cell lysates, DNA/RNA solutions, or reagents.

6. Can Dry Bath Incubator assist in isothermal amplification methods?

It is suitable for isothermal nucleic acid amplification techniques such as tests such as reagent validation, sample incubation, and product consistency checks.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.