Introduction

Potentiostat System offers CV scan rates up to 0.000001 V/s to 10,000 V/s for flexible and correct analysis. Equipped with high-speed signal generator and digital display for monitoring parameters. It features electrochemical sensing, corrosion testing, and has large capacity. Built in compact design, stable current with bias circuit and maximum data length for storage. Potentiostat is ideal in academic, research labs and industries. 

Manufactured under strict quality control processes, complying with international laboratory equipment standards. Provides 1-year warranty for main components and lifetime technical support.

Applications

Potentiostat System is ideal for advanced electrochemical applications in battery and supercapacitor research, electrocatalysis, biosensing, and corrosion testing. 

Selection Guide

Potentiostat System is a precision electrochemical instrument designed for a wide range of research applications, including corrosion studies, battery testing, electroplating, and sensor development. Based on a research study, this system is particularly suitable for experiments requiring high-speed data acquisition and accurate control of potential and current. It supports 2-, 3-, and 4-electrode configurations, providing flexibility for complex electrochemical setups. With a maximum potential range of ±10 V, a maximum current of ±250 mA, and a fast rise time of less than 1 μs, it ensures reliable performance in both basic and advanced research tasks. The compliance voltage of ±13 V enhances its ability to operate under various load conditions. Additionally, this system often meets quality and safety certifications relevant to academic and industrial labs, making it a reliable choice for institutions looking for high-performance and compliant potentiostats.

Specifications

Electrode Configuration 2-, 3-, and 4-electrode
Maximum Potential Range ±10 V
Maximum Current ±250 mA
Compliance Voltage ±13 V
Potentiostat Rise Time Less than 1 μs
Potentiostat Bandwidth 1 MHz
Potential Ranges ±10 mV, ±50 mV, ±100 mV, ±650 mV, ±3.276 V, ±6.553 V, ±10 V
Potential Resolution 0.0015%
Potential Accuracy ±1 mV or ±0.01%
Potential Noise Less than 10 μV RMS
Current Measurement Range ±10 pA to ±0.25 A
Current Resolution 0.0015%
Current Accuracy 0.2%
Input Bias Current Less than 10 pA
Scan Rates (CV/LSV) 0.000001 V/s to 10,000 V/s
Potential Increment (CV) 0.1
Pulse Width (CA/CC) 0.0001 to 1000 s
Sampling Interval (CA/CC) 0.4 μs
DPV/NPV Pulse Width 0.001 to 10 sec
SWV Frequency 1 Hz to 100 kHz
ACV Frequency Range 0.1 Hz to 10 kHz
SHACV Frequency Range 0.1 Hz to 5 kHz
FTACV Frequency Range 0.1 Hz to 50 Hz
AC Impedance Frequency 0.00001 Hz to 3 MHz
AC Impedance Amplitude 0.00001 V to 0.7 V RMS
Current Offset Accuracy 0.003%
Memory Capacity 256,000 to 16,384,000 points
Dimensions 37 cm × 23 × 12 cm
Net Weight 6 kg

Features

Energy-efficient

Multi-step potential

Internal flash memory 

Overload protection 

Low maintenance 

FAQs

1. What is the main function of this Potentiostat System?

It is a professional laboratory instrument designed for Potentiostat System applications, providing accurate, reliable performance for sample analysis, processing, or storage in scientific research and industrial quality control.

2. What are the key advantages of this Potentiostat System compared to similar products?

It combines high performance, user-friendly operation, and robust construction. The compliance with international standards and certifications ensures its reliability and suitability for various laboratory environments.

3. What regular maintenance is required for this Potentiostat System?

General maintenance recommendations: 1) Keeping the instrument clean and free from dust and debris; 2) Following the manufacturer's calibration schedule to maintain accuracy; 3) Inspecting electrical connections and mechanical parts periodically for signs of wear; 4) Storing and using the instrument according to the operating manual to prevent damage.

4. What are the installation requirements for this Potentiostat System?

Standard installation requirements: 1) Placing on a stable, level workbench in a clean laboratory environment; 2) Connecting to a properly grounded power supply matching the instrument's voltage requirements; 3) Ensuring adequate space for operation and maintenance; 4) Following any specific environmental conditions (temperature, humidity, ventilation) outlined in the product manual.

5. What should I do if the Potentiostat System shows abnormal operation?

General troubleshooting guidelines: 1) First check the power supply and all connections to ensure they are secure; 2) Refer to the user manual's troubleshooting section for specific error messages or symptoms; 3) Perform a system reset if applicable; 4) Do not attempt to repair internal components without professional training; contact authorized service personnel for technical support when needed.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.