Introduction
Portable Fume Extractor offers air velocity of 2 × 10 m/s. Its 3-stage system includes pre-filter, middle filter, and main filter for layered purification. Its dual inlet configuration enhances suction efficiency by drawing fumes simultaneously from two directions. Its intuitive controls and alarm system ensure seamless operation with real-time safety alerts. Portable Fume Extractor is ideal for welding, laser processing, chemical manufacturing, and laboratories.
Manufactured under strict quality control processes, complying with international laboratory equipment standards. Provides 1-year warranty for main components and lifetime technical support.
Applications
Portable Fume Extractor is ideal for welding, laser processing, chemical manufacturing and laboratories for removing hazardous fumes, gases, and airborne particles.
Selection Guide
Portable Fume Extractor is designed for safe and efficient air purification in laboratory and industrial settings. Based on a research study, it is welfor applications that involve soldering, chemical experiments, or processes emitting harmful fumes and particulates. This model is particularly suited for environments requiring mobility, compact design, and high-efficiency filtration. It supports multi-stage filtration technology to ensure maximum removal of hazardous substances. Certified for compliance with international safety and filtration standards (such as CE and ISO), it provides reliable performance for academic, research, and manufacturing laboratories. When selecting this unit, consider factors such as air volume capacity, filtration stages, and compatibility with your specific workspace or process—making it a strong choice for users who prioritize safety, portability, and certified air quality.
Specifications
| Air Volume | 320 m³/h |
| Air Velocity | 2 × 10 m/s |
| Filtration | 3 stages |
| Port Diameter | ϕ 75 mm × 2 |
| Filtration Efficiency | 99.97% at 0.3 µm |
| Noise Level | Less than 60 dB |
| Power Consumption | 200 W |
| Power Supply | 220 V, 50 Hz |
| Length of Duct | ϕ 75 mm × 1.4 m |
| Bamboo Duct Dimensions | 410 × 410 × 100 mm. |
| Nozzle dimensions | 130 × 120 × 120 mm |
| Dimensions | 420 × 240 × 450 mm |
| Nozzle Weight | 0.095 kg |
| Weight | 18 kg |
Features
360-degree smoking pipe
Silicone smoking hood
Air-stabilizing flange
Brushless DC motor
Shunt filter design
Caster wheels
Model No. | Accessory Name |
style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;padding:0cm 5.4pt;vertical-align:top;width:163.05pt;"> Prefilter | |
style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;padding:0cm 5.4pt;vertical-align:top;width:163.05pt;"> Medium Efficiency Filter | |
style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;padding:0cm 5.4pt;vertical-align:top;width:163.05pt;"> High Efficiency Filter |
FAQs
1. What is the main function of this Portable Fume Extractor?
It is a professional laboratory instrument designed for Portable Fume Extractor applications, providing accurate, reliable performance for sample analysis, processing, or storage in scientific research and industrial quality control.
2. What are the key advantages of this Portable Fume Extractor compared to similar products?
It combines high performance, user-friendly operation, and robust construction. The compliance with international standards and certifications ensures its reliability and suitability for various laboratory environments.
3. What regular maintenance is required for this Portable Fume Extractor?
General maintenance recommendations: 1) Keeping the instrument clean and free from dust and debris; 2) Following the manufacturer's calibration schedule to maintain accuracy; 3) Inspecting electrical connections and mechanical parts periodically for signs of wear; 4) Storing and using the instrument according to the operating manual to prevent damage.
4. What are the installation requirements for this Portable Fume Extractor?
Standard installation requirements: 1) Placing on a stable, level workbench in a clean laboratory environment; 2) Connecting to a properly grounded power supply matching the instrument's voltage requirements; 3) Ensuring adequate space for operation and maintenance; 4) Following any specific environmental conditions (temperature, humidity, ventilation) outlined in the product manual.
5. What should I do if the Portable Fume Extractor shows abnormal operation?
General troubleshooting guidelines: 1) First check the power supply and all connections to ensure they are secure; 2) Refer to the user manual's troubleshooting section for specific error messages or symptoms; 3) Perform a system reset if applicable; 4) Do not attempt to repair internal components without professional training; contact authorized service personnel for technical support when needed.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.