Introduction
Portable Fume Extractor operates with air flow velocity of 278 m³/h. Its multi-layer filters include pre-filter, HEPA, and activated carbon to remove particles and harmful gases. Its shutter air outlets enable controlled air direction and prevent backflow for efficient smoke extraction. Its compact body with handle and fixed wheels enables ultra-quiet and easy mobility. Portable Fume Extractor is ideal for soldering, laser processing, moxibustion therapy.
Manufactured under strict quality control processes, complying with international laboratory equipment standards. Provides 1-year warranty for main components and lifetime technical support.
Applications
Portable Fume Extractor is ideal for soldering, laser processing, moxibustion therapy, and dust or powder particle extraction.
Selection Guide
Portable Fume Extractor is an advanced air purification system designed to effectively capture and filter harmful fumes, smoke, and airborne particles generated during processes like soldering, laser marking, chemical analysis, and light welding tasks. According to research-based findings, it is particularly well-suited for laboratory use, electronics workshops, and industrial workstations where space is limited but air quality control is essential. The unit features a compact and mobile design for flexible usage and relocation, along with a multi-stage filtration system that ensures high-efficiency removal of hazardous substances. With certifications such as CE and RoHS, it meets international standards for safety, reliability, and environmental compliance. These attributes make this model a reliable and research-backed solution for professionals who prioritize clean, safe, and certified working environments.
Specifications
| Air Flow Velocity | 278 m³/h |
| Port Diameter | Φ75 mm |
| Filtration Efficiency | Greater than or equal to 99.97% at 0.3 µm |
| Noise Level | Less than 55 dB |
| Power Consumption | 180 W |
| Power Supply | 220/ 110 V |
| Bamboo Duct Dimension | 410 × 410 × 100 mm |
| Nozzle dimension | 130 × 120 × 120 mm |
| Dimensions | 280 × 240 × 315 mm |
| Weight | 13 kg |
Features
High suction power
Adjustable suction arm
Low noise operation
Air-stabilizing flange seat
Spin button interface
Shunt design
Model No. | Accessory Name |
style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;padding:0cm 5.4pt;vertical-align:top;width:163.05pt;"> Prefilter | |
style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;padding:0cm 5.4pt;vertical-align:top;width:163.05pt;"> Medium Efficiency Filter | |
style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;padding:0cm 5.4pt;vertical-align:top;width:163.05pt;"> High Efficiency Filter |
FAQs
1. What is the main function of this Portable Fume Extractor?
It is a professional laboratory instrument designed for Portable Fume Extractor applications, providing accurate, reliable performance for sample analysis, processing, or storage in scientific research and industrial quality control.
2. What are the key advantages of this Portable Fume Extractor compared to similar products?
It incorporates advanced technologies including HEPA filtration, ensuring superior performance in terms of stability, accuracy, and operational convenience. The durable construction and strict quality control also guarantee long service life and low maintenance costs.
3. What regular maintenance is required for this Portable Fume Extractor?
General maintenance recommendations: 1) Keeping the instrument clean and free from dust and debris; 2) Following the manufacturer's calibration schedule to maintain accuracy; 3) Inspecting electrical connections and mechanical parts periodically for signs of wear; 4) Storing and using the instrument according to the operating manual to prevent damage.
4. What are the installation requirements for this Portable Fume Extractor?
Standard installation requirements: 1) Placing on a stable, level workbench in a clean laboratory environment; 2) Connecting to a properly grounded power supply matching the instrument's voltage requirements; 3) Ensuring adequate space for operation and maintenance; 4) Following any specific environmental conditions (temperature, humidity, ventilation) outlined in the product manual.
5. What should I do if the Portable Fume Extractor shows abnormal operation?
General troubleshooting guidelines: 1) First check the power supply and all connections to ensure they are secure; 2) Refer to the user manual's troubleshooting section for specific error messages or symptoms; 3) Perform a system reset if applicable; 4) Do not attempt to repair internal components without professional training; contact authorized service personnel for technical support when needed.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.

