Introduction

Stackable Incubator Shaker speed range of 10 to 300 rpm. Its LCD touch screen enables intuitive control and real-time monitoring of operating parameters. Its cyclotron oscillation mode ensures uniform and stable shaking for consistent culturing conditions. Its safety system includes alarms and independent protections for temperature, speed, leakage, and overload risks. Stackable Incubator Shaker supports high-volume microbial growth, fermentation studies, and controlled cell incubation.

Manufactured under strict quality control processes, complying with international laboratory equipment standards. Provides 1-year warranty for main components and lifetime technical support.

Applications

Stackable Incubator Shaker is ideal for growing bacteria, yeast, and other microorganisms, fermentation processes, growth and maintenance of various cell types. 

Specifications

Temperature Control Range 4℃ to 60℃
Ambient Temperature Range 5℃ to 25℃
Temperature Accuracy ±0.1℃
Temperature Uniformity ±0.4℃ at 37℃
Speed Range 10 to 300 rpm
Speed Accuracy ±1 rpm
Shaking Amplitude φ26 mm
Capacity 250ml × 50, 500ml × 35, 1000ml × 20, 2000ml × 12
Maximum Loading Capacity 24 kg
Timer Range 0 to 999.9 Hours
Power Consumption 1000 W /layer
Platform Dimensions 780 × 560 mm(× 1 per layer)
Internal Dimensions 885 × 735 × 495 mm /layer
External Dimensions 1220 × 960 × 650mm /layer
Net Weight 210 kg

Features

UV sterilization 

Equipped with RS232/USB communication interface for data export and remote control. Supports connection to laboratory information management system (LIMS) for centralized data management and traceability.

Daylight Lamp 

Flat Platform with Guide Rail 

Five axis driving mode

Automatic startup and shutdown

Temperature correction

Model No.

Accessory Name

style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;padding:0cm 5.4pt;vertical-align:top;width:163.05pt;">

Flask clamp (50ml)

style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;padding:0cm 5.4pt;vertical-align:top;width:163.05pt;">

Flask clamp (100ml)

style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;padding:0cm 5.4pt;vertical-align:top;width:163.05pt;">

Flask clamp (150ml)

style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;padding:0cm 5.4pt;vertical-align:top;width:163.05pt;">

Flask clamp (200ml)

style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;padding:0cm 5.4pt;vertical-align:top;width:163.05pt;">

Flask clamp (250ml)

style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;padding:0cm 5.4pt;vertical-align:top;width:163.05pt;">

Flask clamp (500ml)

style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;padding:0cm 5.4pt;vertical-align:top;width:163.05pt;">

Flask clamp (1000ml)

style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;padding:0cm 5.4pt;vertical-align:top;width:163.05pt;">

Flask clamp (2000ml)

style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;padding:0cm 5.4pt;vertical-align:top;width:163.05pt;">

Flask clamp (3000ml)

style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;padding:0cm 5.4pt;vertical-align:top;width:163.05pt;">

Flask clamp (5000ml)

style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;padding:0cm 5.4pt;vertical-align:top;width:163.05pt;">

96 Micro Plate Holder

style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;padding:0cm 5.4pt;vertical-align:top;width:163.05pt;">

Paste adhesive pad (20 × 20cm)

style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;padding:0cm 5.4pt;vertical-align:top;width:163.05pt;">

Spring Clamp(Small)

style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;padding:0cm 5.4pt;vertical-align:top;width:163.05pt;">

Spring Clamp(Large)

style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;padding:0cm 5.4pt;vertical-align:top;width:163.05pt;">

Tube rack clamp

FAQs

1. What is the main function of this Stackable Incubator Shaker?

It is a professional laboratory instrument designed for Stackable Incubator Shaker applications, providing accurate, reliable performance for sample analysis, processing, or storage in scientific research and industrial quality control.

2. What are the key advantages of this Stackable Incubator Shaker compared to similar products?

It incorporates advanced technologies including touch screen control, ensuring superior performance in terms of stability, accuracy, and operational convenience. The durable construction and strict quality control also guarantee long service life and low maintenance costs.

3. What regular maintenance is required for this Stackable Incubator Shaker?

General maintenance recommendations: 1) Keeping the instrument clean and free from dust and debris; 2) Following the manufacturer's calibration schedule to maintain accuracy; 3) Inspecting electrical connections and mechanical parts periodically for signs of wear; 4) Storing and using the instrument according to the operating manual to prevent damage.

4. What are the installation requirements for this Stackable Incubator Shaker?

Installation should meet: 1) Placing the instrument in a well-ventilated area with at least 10cm clearance around the sides and back for heat dissipation; 2) Ensuring a stable, level surface capable of supporting the instrument's weight; 3) Connecting to a dedicated power supply with appropriate voltage and grounding to prevent electrical issues; 4) Avoiding direct sunlight, heat sources, and areas with high humidity or dust.

5. What should I do if the Stackable Incubator Shaker shows abnormal operation?

General troubleshooting guidelines: 1) First check the power supply and all connections to ensure they are secure; 2) Refer to the user manual's troubleshooting section for specific error messages or symptoms; 3) Perform a system reset if applicable; 4) Do not attempt to repair internal components without professional training; contact authorized service personnel for technical support when needed.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.