Introduction
Handheld LIBS Analyzer detects carbon and other elements within 5 to 6 seconds. It features lightweight construction, allowing effortless handheld operation for on-site material testing. Equipped with an integrated macro camera, it allows reliable sample positioning and measurement. Incorporates resistive touch screen display for clear viewing in field conditions. LIBS Analyzer is ideal for elemental analysis of metals and alloys in various sectors.
Calibrated according to national metrology standards, ensuring measurement accuracy and traceability. The instrument has passed CE certification, suitable for use in international markets.
Applications
Handheld LIBS Analyzer enables rapid elemental analysis of stainless steel, alloy steel, carbon steel, and other metals in manufacturing, recycling, and on-site inspection fields.
Selection Guide
Handheld LIBS Analyzer a portable, high-performance elemental analyzer ideal for on-site material identification and composition analysis. Based on research studies and industrial applications, this analyzer is extensively used in fields like metal recycling, mining, aerospace, automotive, and manufacturing quality control. It is particularly effective in detecting light elements such as Li, Be, B, Mg, Al, and Si, which are often challenging for other analyzers. It supports rapid testing (1–6 seconds) and provides real-time analysis with high accuracy, making it suitable for alloy sorting, material verification, and quality assurance experiments. The device complies with international standards such as CE and ISO certifications, ensuring its reliability and safety in demanding environments. Customers in metallurgy labs, scrap processing units, research institutions, and industrial production lines can confidently select this model for its speed, precision, and compliance with global quality standards.
Specifications
| Detectable Elements | C,Al,Ti, Si, Cr, Mn, Fe, Co, Ni, Cu,Mo etc. |
| Testing Time | 5 to 6s |
| Detection Method | Plasma emission spectroscopy |
| Camera | CCD macro camera |
| Display | 4.0-inch resistive touch screen, 320×480 pixels |
| Laser | Class 3B, 1064 nm laser |
| Data Transmission | 2.4G/5.0GHz802.1lac/n/b/a wireless LAN |
| Bluetooth | Bluetooth 4.1 |
| Waterproof Rating | IP54 |
| Resolution | Less than 0.1nm |
| Database | 50+ common grades, customizable with Vela Soft |
| Working Temperature | 0 to 40℃ |
| Power Supply | Lithium-ion battery, 16.8V, 43Wh |
| Dimensions | 90×280×150mm |
| Weight | 1.8Kg |
| Repeatability | ≤2% RSD |
Features
High-Power Laser
Equipped with RS232/USB communication interface for data export and remote control. Supports connection to laboratory information management system (LIMS) for centralized data management and traceability.
Dual-Band Wi-Fi
Desktop Charging
Password Security
Interlocking Safety
Single-Point Calibration
FAQs
1. What is the main function of this Handheld Libs Analyzer?
It is a professional laboratory instrument designed for Handheld Libs Analyzer applications, providing accurate, reliable performance for sample analysis, processing, or storage in scientific research and industrial quality control.
2. What are the key advantages of this Handheld Libs Analyzer compared to similar products?
It incorporates advanced technologies including touch screen control, ensuring superior performance in terms of stability, accuracy, and operational convenience. The durable construction and strict quality control also guarantee long service life and low maintenance costs.
3. What regular maintenance is required for this Handheld Libs Analyzer?
General maintenance recommendations: 1) Keeping the instrument clean and free from dust and debris; 2) Following the manufacturer's calibration schedule to maintain accuracy; 3) Inspecting electrical connections and mechanical parts periodically for signs of wear; 4) Storing and using the instrument according to the operating manual to prevent damage.
4. What are the installation requirements for this Handheld Libs Analyzer?
Installation requirements include: 1) Selecting a vibration-free location to ensure measurement accuracy; 2) Providing stable power supply with voltage regulation if necessary; 3) Ensuring proper ventilation for instruments requiring gas exhaust; 4) Maintaining appropriate ambient temperature (usually 5-40℃) and humidity (≤85%) as specified in the operating manual.
5. What should I do if the Handheld Libs Analyzer shows abnormal operation?
General troubleshooting guidelines: 1) First check the power supply and all connections to ensure they are secure; 2) Refer to the user manual's troubleshooting section for specific error messages or symptoms; 3) Perform a system reset if applicable; 4) Do not attempt to repair internal components without professional training; contact authorized service personnel for technical support when needed.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.