Introduction
Automatic Colony Counter counts 1000 colonies in less than 1 second. It features high-resolution imaging for detailed colony detection and differentiation. Integrated with adjustable lighting to enhance colony visibility during counting. Equipped with customizable settings to accommodate diverse sample types. Counter is ideal for microbiological analysis in research, quality control, and healthcare laboratories.
Manufactured under strict quality control processes, complying with international laboratory equipment standards. Provides 1-year warranty for main components and lifetime technical support.
Applications
Automatic Colony Counter is widely used in automatic colony counting, reading for quantitative studies, quality and research purposes across microbiology, hospitals, cosmetic, food industries, and pharmaceuticals units.
Selection Guide
Automatic Colony Counter is a high-performance device designed for accurate and rapid counting of microbial colonies on agar plates. It is commonly used in pharmaceutical quality control, food and beverage testing, clinical diagnostics, and microbiological research. With a counting speed of up to 1000 colonies in less than 1 second and equipped with a high-resolution camera and smart counting software, it provides accurate and consistent results even in dense or overlapping colonies. This model is particularly useful for applications such as microbial load testing, antibiotic effectiveness studies, and hygiene monitoring. Certified with ISO and CE standards, this model guarantees safety, reliability, and regulatory compliance, making it a suitable choice for research and industrial laboratories requiring speed, accuracy, and efficiency.
Specifications
| Counting Speed | Less than 1 second for counting 1000 colonies |
| Camera Resolution | 12,000,000 pixels |
| Camera | True Color High Definition Camera |
| Color Temperature | 3000K to 7700K |
| Upper Light Source Illumination | 51.7 to 985.1 Lux |
| Illumination Type | 360° shadowless illumination |
| Light Direction | Multi-directional transmitted light |
| Brightness Control | Adjustable brightness |
| Lower Light Source Illumination | 0 to 4500 Lux |
| Light Type | Bottom transmitted light darkroom shooting system |
| Sideview | Ring matrix system |
| Sensor | Complementary Metal-Oxide-Semiconductor |
| Operating Temperature | 0°C to 35°C |
| Imaging Capturing System | Auto Focus, Auto White Balance, Auto Color Temperature Control |
| Automatic Impurity Removal | Automatically eliminates impurities based on shape, size, and color differences |
| Colony Morphology Analysis | Automatic analysis of area, girth, roundness, max/min diameters |
| Selectable Counting Area | Choose from circle, semicircle, rectangle, sector, or custom areas |
| Image Processing | Image enhancement, adaptive enhancement, edge sharpening, image flattening |
| Image Filtering Options | Low filter, high filter, Gaussian filter, and more |
| Edge Detection Methods | Sobel, Roberts, Laplace, vertical, and horizontal detection |
| Image Adjustment Options | Adjust gray scale, brightness, contrast, and gamma settings |
| Morphological Operations | Erosion, dilation, opening, and closing operations |
| Image Segmentation | RGB and grayscale segmentation |
| Colony Labeling | Various labeling options (lines, angles, rectangles, curves, etc) |
| Colony Measurement | Measures line, angle, rectangle, circular arc, and more |
| Petri Dish Compatibility | Supports 90mm and 100mm petri dishes |
| Power Consumption | ≤100W |
| Power Supply | 220v 50hz |
| Dimension | 350×398×510 mm |
| Weight | 12 kg |
Features
Built-in UV lamp
Calibration functionality
Monochrome designs
Multicolor patterns
Rapid statistical analysis
Standard Accessories
FAQs
1. What is the main function of this Automatic Colony Counter?
It is a professional laboratory instrument designed for Automatic Colony Counter applications, providing accurate, reliable performance for sample analysis, processing, or storage in scientific research and industrial quality control.
2. What are the key advantages of this Automatic Colony Counter compared to similar products?
It combines high performance, user-friendly operation, and robust construction. The compliance with international standards and certifications ensures its reliability and suitability for various laboratory environments.
3. What regular maintenance is required for this Automatic Colony Counter?
General maintenance recommendations: 1) Keeping the instrument clean and free from dust and debris; 2) Following the manufacturer's calibration schedule to maintain accuracy; 3) Inspecting electrical connections and mechanical parts periodically for signs of wear; 4) Storing and using the instrument according to the operating manual to prevent damage.
4. What are the installation requirements for this Automatic Colony Counter?
Standard installation requirements: 1) Placing on a stable, level workbench in a clean laboratory environment; 2) Connecting to a properly grounded power supply matching the instrument's voltage requirements; 3) Ensuring adequate space for operation and maintenance; 4) Following any specific environmental conditions (temperature, humidity, ventilation) outlined in the product manual.
5. What should I do if the Automatic Colony Counter shows abnormal operation?
General troubleshooting guidelines: 1) First check the power supply and all connections to ensure they are secure; 2) Refer to the user manual's troubleshooting section for specific error messages or symptoms; 3) Perform a system reset if applicable; 4) Do not attempt to repair internal components without professional training; contact authorized service personnel for technical support when needed.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.