Introduction

Automatic Colony Counter counts 1000 colonies in less than 1 second. It features high-resolution imaging for detailed colony detection and differentiation. Integrated with adjustable lighting to enhance colony visibility during counting. Equipped with customizable settings to accommodate diverse sample types. Counter is ideal for microbiological analysis in research, quality control, and healthcare laboratories.

Manufactured under strict quality control processes, complying with international laboratory equipment standards. Provides 1-year warranty for main components and lifetime technical support.

Applications

Automatic Colony Counter is widely used in automatic colony counting, reading for quantitative studies, quality and research purposes across microbiology, hospitals, cosmetic, food industries, and pharmaceuticals units.

Selection Guide

Automatic Colony Counter is a high-performance device designed for accurate and rapid counting of microbial colonies on agar plates. It is commonly used in pharmaceutical quality control, food and beverage testing, clinical diagnostics, and microbiological research. With a counting speed of up to 1000 colonies in less than 1 second and equipped with a high-resolution camera and smart counting software, it provides accurate and consistent results even in dense or overlapping colonies. This model is particularly useful for applications such as microbial load testing, antibiotic effectiveness studies, and hygiene monitoring. Certified with ISO and CE standards, this model guarantees safety, reliability, and regulatory compliance, making it a suitable choice for research and industrial laboratories requiring speed, accuracy, and efficiency.

Specifications

Counting Speed Less than 1 second for counting 1000 colonies
Camera Resolution 12,000,000 pixels
Camera True Color High Definition Camera
Color Temperature 3000K to 7700K
Upper Light Source Illumination 51.7 to 985.1 Lux
Illumination Type 360° shadowless illumination
Light Direction Multi-directional transmitted light
Brightness Control Adjustable brightness
Lower Light Source Illumination 0 to 4500 Lux
Light Type Bottom transmitted light darkroom shooting system
Sideview Ring matrix system
Sensor Complementary Metal-Oxide-Semiconductor
Operating Temperature 0°C to 35°C
Imaging Capturing System Auto Focus, Auto White Balance, Auto Color Temperature Control
Automatic Impurity Removal Automatically eliminates impurities based on shape, size, and color differences
Colony Morphology Analysis Automatic analysis of area, girth, roundness, max/min diameters
Selectable Counting Area Choose from circle, semicircle, rectangle, sector, or custom areas
Image Processing Image enhancement, adaptive enhancement, edge sharpening, image flattening
Image Filtering Options Low filter, high filter, Gaussian filter, and more
Edge Detection Methods Sobel, Roberts, Laplace, vertical, and horizontal detection
Image Adjustment Options Adjust gray scale, brightness, contrast, and gamma settings
Morphological Operations Erosion, dilation, opening, and closing operations
Image Segmentation RGB and grayscale segmentation
Colony Labeling Various labeling options (lines, angles, rectangles, curves, etc)
Colony Measurement Measures line, angle, rectangle, circular arc, and more
Petri Dish Compatibility Supports 90mm and 100mm petri dishes
Power Consumption ≤100W
Power Supply 220v 50hz
Dimension 350×398×510 mm
Weight 12 kg

Features

Built-in UV lamp

Calibration functionality

Monochrome designs

Multicolor patterns

Rapid statistical analysis

Standard Accessories

FAQs

1. What is the main function of this Automatic Colony Counter?

It is a professional laboratory instrument designed for Automatic Colony Counter applications, providing accurate, reliable performance for sample analysis, processing, or storage in scientific research and industrial quality control.

2. What are the key advantages of this Automatic Colony Counter compared to similar products?

It combines high performance, user-friendly operation, and robust construction. The compliance with international standards and certifications ensures its reliability and suitability for various laboratory environments.

3. What regular maintenance is required for this Automatic Colony Counter?

General maintenance recommendations: 1) Keeping the instrument clean and free from dust and debris; 2) Following the manufacturer's calibration schedule to maintain accuracy; 3) Inspecting electrical connections and mechanical parts periodically for signs of wear; 4) Storing and using the instrument according to the operating manual to prevent damage.

4. What are the installation requirements for this Automatic Colony Counter?

Standard installation requirements: 1) Placing on a stable, level workbench in a clean laboratory environment; 2) Connecting to a properly grounded power supply matching the instrument's voltage requirements; 3) Ensuring adequate space for operation and maintenance; 4) Following any specific environmental conditions (temperature, humidity, ventilation) outlined in the product manual.

5. What should I do if the Automatic Colony Counter shows abnormal operation?

General troubleshooting guidelines: 1) First check the power supply and all connections to ensure they are secure; 2) Refer to the user manual's troubleshooting section for specific error messages or symptoms; 3) Perform a system reset if applicable; 4) Do not attempt to repair internal components without professional training; contact authorized service personnel for technical support when needed.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.