Introduction

Automatic Sulphur Analyzer is a highly specialized and technologically advanced analyzer designed for the precise and efficient analysis of sulphur content in various materials. Accommodates a total of 21 samples and detects sulphur concentrations of up to 100% in a remarkably short span of 3 to 10 minutes. It represents an advancement in sulphur content analysis, offering speed, precision, and ease of use for a wide range of applications.

Calibrated according to national metrology standards, ensuring measurement accuracy and traceability. The instrument has passed CE certification, suitable for use in international markets.

Applications

It is employed for quantifying the overall sulphur concentration in coal, coke, and petroleum in a wide range of industries, including electric power, coal, metallurgy, petrochemicals, environmental protection, cement production, papermaking, land surveying, as well as scientific research institutions, among others.

Selection Guide

Automatic Sulphur Analyzer is a high-precision instrument widely used in research and industrial applications such as petroleum refining, coal processing, metallurgy, and chemical production, where accurate sulphur content analysis is essential. It supports up to 21 samples with a broad measuring range of 0 to 100%, high accuracy of 1.0E-5, and resolution of 1.0E-5, operating at a test temperature of 1150°C for complete combustion. This analyzer is suitable for combustion studies, elemental analysis, and quality control experiments, particularly in environments requiring strict compliance with ISO and ASTM standards. With its advanced features and certifications, this model is a preferred choice among petrochemical labs, steel industries, environmental agencies, and academic research institutions looking for reliable and efficient sulphur testing solutions.

Specifications

Capacity 21 samples
Measuring Range 0 to 100%
Accuracy 1.0E-5
Test Resolution 1.0E-5
Test Temperature 1150°C
Analysis Time 3 to 10 mins
Operating System Windows
Power Supply AC 220 V, 50 Hz
Packaging Dimension (W×D×H) 9500×5700×5600 mm
Gross Weight 75 kg
Repeatability ≤2% RSD

Features

Enhanced with a microcomputer-controlled system capable of swiftly and precisely measuring sulphur content
Features an integrated structure for the automated determination of titration endpoint
Provides flexibility through user-defined time settings for sample delivery and temperature presets
Employs an imported hall element for controlling sample feeding and an electronic switch for sample delivery
Unique data acquisition network, utilizing the Windows operating system, with a high automation degree
Integrates advanced technologies, including multi-level correction and serial communication, to enhance its analytical capabilities
It supports USB communication for simplified data processing and analysis

FAQs

1. What is the main function of this Automatic Sulphur Analyzer?

It is a professional laboratory instrument designed for Automatic Sulphur Analyzer applications, providing accurate, reliable performance for sample analysis, processing, or storage in scientific research and industrial quality control.

2. What are the key advantages of this Automatic Sulphur Analyzer compared to similar products?

It provides high measurement accuracy, fast analysis speed, and good repeatability. The automatic calibration and self-diagnostic functions reduce human error and ensure reliable test results for critical applications.

3. What regular maintenance is required for this Automatic Sulphur Analyzer?

General maintenance recommendations: 1) Keeping the instrument clean and free from dust and debris; 2) Following the manufacturer's calibration schedule to maintain accuracy; 3) Inspecting electrical connections and mechanical parts periodically for signs of wear; 4) Storing and using the instrument according to the operating manual to prevent damage.

4. What are the installation requirements for this Automatic Sulphur Analyzer?

Installation requirements include: 1) Selecting a vibration-free location to ensure measurement accuracy; 2) Providing stable power supply with voltage regulation if necessary; 3) Ensuring proper ventilation for instruments requiring gas exhaust; 4) Maintaining appropriate ambient temperature (usually 5-40℃) and humidity (≤85%) as specified in the operating manual.

5. What should I do if the Automatic Sulphur Analyzer shows abnormal operation?

General troubleshooting guidelines: 1) First check the power supply and all connections to ensure they are secure; 2) Refer to the user manual's troubleshooting section for specific error messages or symptoms; 3) Perform a system reset if applicable; 4) Do not attempt to repair internal components without professional training; contact authorized service personnel for technical support when needed.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.