Introduction
Digital microscope is a compact bench-top unit with inbuilt digital camera to capture vivid images and real time videos. LED illumination with rheostat brightness control aids to achieve high quality images. Coaxial coarse and fine adjustment focus knob with tension adjustment aids in mobility of the objective lenses. Vertically movable condenser with iris diaphragm and filter holder on rack and pinion.
Applications
Used in hospitals, clinics, medical academics, morphology and related research centers for biological, pathology, bacterial, histological, immune, genetics and pharmacological analysis.
Specifications
| Viewing head | Siedentopf binocular |
| Inter-pupillary distance | 48 mm ⁓75 mm |
| Eyepiece ( Extra wide field ) | EW10X / 20 mm |
| Camera system | 1.3 MP |
| Semi-plan achromatic objective | 4X 10X 40X 100X |
| Camera resolution | ( 1280 × 1024 ) pixels |
| Software | ScopeImage 9.0 |
| Viewing head inclination | 30° |
| Stage | USB2.0 |
| Moving range (stage ) | 140 mm × 140 mm 75 mm × 50 mm |
| Illumination | Abbe NA1.25 |
| Dimensions | 1 W S-LED |
| Weight | 350 × 310 × 570 mm |
Features
Seidentopf type binocular viewing head
Inbuilt CMOS camera(1.3 MP)
Software support(Image analysis)
Reverse quadruple nosepiece
Viewing head with 10X widefield eyepieces
Large mechanical stage(double layered)
Filter : Blue and green(increases contrast and removes UV light)
FAQ
Q1: What is the magnification range of this microscope?
A1: The magnification range is 40× to 800× (e.g., 40× to 1000× for biological microscopes), with replaceable objectives for different observation needs.
Q2: Does it support digital imaging?
A2: Yes, with built-in 5MP digital camera - Some models are equipped with a digital camera interface, which can be connected to a computer for image capture and analysis.
Q3: How to adjust the focus for clear observation?
A3: It has coarse and fine adjustment knobs. First use the coarse adjustment to find the sample, then use the fine adjustment to get a clear image.
Q4: What type of light source does it use?
A4: It adopts a LED light source, which has long service life (up to 50000 hours) and stable brightness, without frequent bulb replacement.
Q5: Is the microscope easy to maintain?
A5: Regular maintenance only requires wiping the lenses with lens paper and keeping the stage clean. Avoid touching the lens surface with fingers.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.

