Introduction

Benchtop low speed refrigerated centrifuge is a microcomputer controlled unit with a speed of 5500 rpm and temperature ranging from -20 ℃ ~ 40 ℃. Allows automated configuration of speed and RCF value with short spin press function for instant centrifugation. Equipped with digitalized LED panel for observing and regulating ongoing parameters (speed, time and temperature).

Applications

Used for isolation and purification of blood samples, clinical medicine, radioactive immunology, biochemistry, pharmaceutics

Specifications

Speed range5500 rpm
Maximum RCF5310 × g
Speed accuracy± 20 rpm
Time range1 min ~ 99 mins
Maximum capacity4 × 750 ml
Temperature range-20 ℃ ~ 40 ℃
Temperature accuracy± 2.0 ℃
Power supplyAC 220 V ± 22 V, 50 Hz, 15A
Power1500 W
Noise level< 65 dB
Dimensions645 mm × 700 mm × 445 mm
Weight95 kg

Features

Maximum speed - 5500 rpm

Short spin function for instantaneous centrifugation

Automatically calibrates speed and centrifugal force value

Microprocessor control feature, automatically detects rotors and speed limit

Ten types of acceleration and deceleration control, with free stopping 9th control time longer than 540s

Maintains lower temperature value (-4 °C), even at maximum speed

LED control panel - viewing and regulating ongoing parameters (speed, time and temperature)

Secondary display for viewing countdown less than one minute

User friendly interface for convenient simple operation

Electronic lid locking system for user’s safety (over speed protection and accidental outburst)

Lid opens automatically on completion, preventing overheating of samples

Variable replaceable rotors for different sample concentrations

FAQ

Q1: What is the maximum rotational speed of this centrifuge?
A1: The maximum speed is 4000 RPM (varies by model), such as 15000 RPM for high-speed models and 4000 RPM for low-speed models.

Q2: Does it have a refrigeration function?
A2: Yes, it is a refrigerated centrifuge - Refrigerated models can maintain a temperature range of -20°C to 40°C, while non-refrigerated models operate at ambient temperature.

Q3: What is the maximum capacity of the rotor?
A3: The standard rotor can hold 24×10ml test tubes (e.g., 12×15ml test tubes), and optional rotors are available for different tube sizes.

Q4: How to ensure the safety of centrifugation operation?
A4: It is equipped with multiple safety protections, including imbalance detection, door lock protection, and over-temperature/over-speed protection.

Q5: What is the recommended maintenance cycle?
A5: It is recommended to clean the rotor and chamber after each use, and perform a comprehensive maintenance check every 6 months (or 500 operating hours).