Introduction

High Speed Centrifuge is an intelligent unit with microcomputer control and automatic rotor identification system. Features 4×750 ml of capacity and 21000 rpm speed with 31060×g of RCF. Ergonomic design with noise reduction system and automatic lid lock, has dual operation modes and also features parameters revision during running operation.

Applications

High Speed Centrifuge is used across cellular biology, biotechnology, research, genomics, diagnostic and clinical biology to acquire rapid precipitation of the sample, extract serum from blood, microcell separation, microbiological sample treatment, PCR experimental zone centrifugation, etc.

Specifications

Max speed21000 rpm
Max RCF31060×g
Max capacity4×750 ml
Revolution/min± 10 r/min
Noise≤ 62 dB
Time control1 sec to 99 h 59 min
Power supplyAC 220 ± 22 V, 50 Hz
Power1000 W
Dimension (W×D×H)580×465×395 mm
Weight61 kg

Features

An intelligent high-speed centrifuge with microcomputer control

Automatic rotor identification system with rotor lock

Stainless steel structure with anti-corrosion coating treatment

Automatic lid lock with one-press centrifuge cover closure

Over speed, over heat and unbalance protection for safe operation

Noise reduction system for quiet and smooth operation

Linear drive with 10 kinds of acceleration and deceleration

Compact, safe and reliable unit to achieve optimum centrifugation

FAQ

Q1: What is the maximum rotational speed of this centrifuge?
A1: The maximum speed is 15000 RPM (varies by model), such as 15000 RPM for high-speed models and 4000 RPM for low-speed models.

Q2: Does it have a refrigeration function?
A2: No, it is a non-refrigerated centrifuge - Refrigerated models can maintain a temperature range of -20°C to 40°C, while non-refrigerated models operate at ambient temperature.

Q3: What is the maximum capacity of the rotor?
A3: The standard rotor can hold 12×15ml test tubes (e.g., 12×15ml test tubes), and optional rotors are available for different tube sizes.

Q4: How to ensure the safety of centrifugation operation?
A4: It is equipped with multiple safety protections, including imbalance detection, door lock protection, and over-temperature/over-speed protection.

Q5: What is the recommended maintenance cycle?
A5: It is recommended to clean the rotor and chamber after each use, and perform a comprehensive maintenance check every 6 months (or 500 operating hours).

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.