Introduction

High Speed Refrigerated Centrifuge at maximum speed of 21,000 rpm and generates an RCF of 29,060 × g. It provides 10 selectable acceleration and deceleration rates, enabling gentle handling of delicate samples It is equipped with a CFC-free refrigeration system with pre-cooling functionality to maintain sample integrity. centrifuge features LCD screen for real-time monitoring and parameters adjustments.

Applications

High Speed Refrigerated Centrifuge is used for rapid and reliable separation of cells, proteins, and other biological materials It is widely used in hospitals, veterinary clinics, food testing laboratories, academic institutions, pharmaceutical labs, and cell culture facilities.

Specifications

Speed Range0 to 21,000 rpm (adjustable)
Maximum Speed21,000 rpm
Speed Accuracy±20 rpm
RCF Range0 to 29,060 × g (adjustable)
Maximum RCF29,060 × g
Maximum Capacity4 × 800 ml
Centrifugal Chamber DiameterØ420 mm
Temperature Control Range-20 °C to +60 °C
Minimum Rotor TemperatureBelow 4 °C at 4600 or 10,000 rpm
Temperature Control Accuracy±1℃
Acceleration/Declaration Rates10 / 10 rates
DisplayLCD
Timer Range1 to 99 hours 59 minutes (adjustable)
Noise Level≤60 dB(A)
Number of Programs29
Power Consumption1800 W
Power SupplyAC 220V, 50Hz, 16A
Product Dimension (L × W × H)735 × 660 × 390 mm
Packaging Dimension (L × W × H)735 × 660 × 390 mm
Net Weight96 kg
Gross Weight128 kg

Features

Adjustable speed range

Large sample capacity

Automatic rotor identification

29 pre-set programs

Emergency lid-lock release

Microprocessor-controlled system

Automatic RPM/RCF conversion

Automatic fault detection

Low-noise operation

FAQ

Q1: What is the maximum rotational speed of this centrifuge?
A1: The maximum speed is 15000 RPM (varies by model), such as 15000 RPM for high-speed models and 4000 RPM for low-speed models.

Q2: Does it have a refrigeration function?
A2: Yes, it is a refrigerated centrifuge - Refrigerated models can maintain a temperature range of -20°C to 40°C, while non-refrigerated models operate at ambient temperature.

Q3: What is the maximum capacity of the rotor?
A3: The standard rotor can hold 12×15ml test tubes (e.g., 12×15ml test tubes), and optional rotors are available for different tube sizes.

Q4: How to ensure the safety of centrifugation operation?
A4: It is equipped with multiple safety protections, including imbalance detection, door lock protection, and over-temperature/over-speed protection.

Q5: What is the recommended maintenance cycle?
A5: It is recommended to clean the rotor and chamber after each use, and perform a comprehensive maintenance check every 6 months (or 500 operating hours).

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.