Introduction
A decapping centrifuge is a specialized centrifuge used for the removal of the caps from the tubes in the laboratories, by the centrifugation, and it is used in the clinical, the research, the pharmaceutical, and the many other laboratories for the safe and the efficient decapping of the tubes. The decapping centrifuge consists of a rotor that holds the tubes, a decapping mechanism, which removes the caps during the centrifugation or after the centrifugation, a motor, a control, and a safety lid, and it removes the caps from the tubes, such as the vacuum blood collection tubes and the sample tubes, with the containment of the aerosols and the spills, and it provides a safe and an efficient decapping, with features such as the adjustable speed and the safety features; the decapping centrifuge is used for the removal of the caps from the blood collection tubes, for the decapping of the sample tubes before the analysis, for the automation of the decapping in the clinical laboratories, for the reduction of the manual labor, for the safety, and for many other applications, and it is available in various capacities, from the small models to the large models for the high throughput; the decapping centrifuge is an essential instrument in the modern clinical laboratory. Decapping centrifuges are used in the clinical laboratories, in the research laboratories, in the pharmaceutical industry, in the blood banks, and for many other applications. With their decapping, decapping centrifuges are essential for the laboratory automation.
Automatic Decapping Centrifuge LDCC-T2012
Automatic Decapping Centrifuge has a maximum speed of 5000 rpm with an accuracy of ± 10 rpm. It features a large filtration and UV sterilization to minimize contamination risks. Our cen...
Automatic Decapping Centrifuge LDCC-T2011
Automatic Decapping Centrifuge has a maximum speed of 5000 rpm with an accuracy of ± 10 rpm. It features an independent UV sterilization function allows thorough disinfection of the cha...
Automatic Decapping Centrifuge LDCC-T2010
Automatic Decapping Centrifuge features a maximum speed of 5000 rpm with an accuracy of ± 10 rpm. It uses a multi-stage filtration system consisting of primary, medium, and high-efficie...
Standards
IEC 61010-2-020:2016-Particular requirements for laboratory centrifuges
Complies with the above standards, but is not limited to them.
Features
1. Decapping centrifuge for sample decapping.
2. Centrifuge with automated cap removal.
3. For clinical sample tubes.
4. Includes centrifuge, rotor and controls.
5. Spins and decaps tubes in workflow.
FAQ
Q1: What scenarios is this centrifuge used for?
A: It spins capped clinical tubes and removes caps in the workflow to speed processing in clinical laboratories. It is used in laboratory, production and field settings, and our team can recommend a suitable configuration for your specific application.
Q2: What standards does it comply with?
A: It follows IEC 61010 and related GB/T standards, with speed and imbalance protection verified. Final inspection verifies these parameters before delivery, and the supporting compliance records are available when the order is placed.
Q3: What is the warranty?
A: It carries a 12 to 24 month warranty covering drive and controls. Rotors and seals are wear parts. Damage from imbalance is excluded.
Q4: Is it hard to operate?
A: It requires trained staff for rotors and tube compatibility. We provide a manual and training.
Q5: What is the lead time?
A: Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.
Q6: Is calibration required?
A: We recommend verification against traceable standards at regular intervals, typically every 6 to 12 months, and keeping calibration records for audit purposes. The manual describes the procedure, and reference standards are available from us. Accredited third-party calibration can also be arranged on request.
Q7: Are consumables universal?
A: Compatible items are single-use consumables designed for this application. They are widely available in standard sizes, and we can supply them directly or confirm the specification so you can source them locally. Ongoing cost is limited to these consumables, and there are no proprietary locked parts.
Q8: Can it be customized?
A: Yes, several configurations are available. Options include rotor types, decapping heads and data output. We can discuss further custom requirements, confirm feasibility and advise any effect on the schedule before the order is confirmed.
Q9: Is installation included?
A: No installation is required for this unit. It is ready to run after a simple power connection and the leveling steps shown in the manual. We supply a detailed operation guide and online setup videos, and on-site commissioning can be arranged separately if your facility requires it.
Q10: What tubes are compatible?
A: It handles capped tubes within rotor and decapping head limits. It is not for non-standard tubes, uncapped samples, or volumes beyond the rotor.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.