Introduction
A reflectivity tester is an instrument used to measure the reflectance or the reflectivity of the surfaces and the materials, and it is used in the coating, the paint, the optics, the road, and the many other industries. The reflectivity tester measures the reflectance by the illumination of the surface with the light at a specified angle and the measurement of the reflected light, and it provides the reflectance, expressed in percent or in the other units, and it may measure the specular reflectance, the diffuse reflectance, and the retroreflectance, depending on the application; the reflectivity tester consists of a light source, the optics, a detector, and a control and a display unit, and it provides features such as the various measurement geometries and the digital display; the reflectivity tester is used for the measurement of the reflectivity of the paints and the coatings, for the measurement of the retroreflectivity of the road markings and the signs, for the measurement of the reflectance of the optical coatings, for the quality control, for the safety, and for many other applications, and it is available as the portable and the benchtop instruments; the reflectivity tester is an essential instrument for the reflectance measurement. Reflectivity testers are used in the paint and the coating industry, in the road and the traffic safety, in the optics, in the automotive industry, and for many other applications. With their reflectivity measurement, reflectivity testers are essential for the quality and the safety.
Reflectivity Tester LRFT-T2010
Reflectivity Tester is designed to measure the spectral reflectance with a wavelength range of 360 nm to 1100nm. It is suitable for tiny, ultra-thin, and curved samples that cannot be me...
Automobile Rearview Mirror Reflectivity Tester LRFT-T2012
Automobile Rearview Mirror Reflectivity Tester is designed to measure reflectivity within the region with a spectral range of 900 to 1700 nm. It has a stable integrating sphere that ensu...
Automobile Rearview Mirror Reflectivity Tester LRFT-T2011
Automobile Rearview Mirror Reflectivity Tester that covers the visible region with a wavelength range of 400 to 1000 nm. It's a flexible and user-friendly design that fits various test e...
Automobile Rearview Mirror Reflectivity Tester LRFT-T2010
Automobile Rearview Mirror Reflectivity Tester uses an 8° angle test method with an integrating sphere, covering a wavelength range of 250 to 800 nm. It measures reflectivity, reflectio...
Reflectivity And Transmittance Tester LRFT-T2010
Reflectivity and Transmittance Tester offers a wide wavelength range of 360 to 1000 nm. It is built with a unique dual optical path design that enables fast switching between transmittan...
Reflectivity Tester LRFT-T2010
Reflectivity Tester is designed to evaluate reflectivity and the reflectivity curve with a broad spectrum range of 380 to 1000nm. It is equipped with advanced an embedded computer, ensur...
Standards
ASTM E903-20-Standard Test Method for Solar Absorptance, Reflectance, and Transmittance of Materials Using Integrating Spheres
Complies with the above standards, but is not limited to them.
Features
1. Reflectivity tester for surface reflectance.
2. Tester measuring reflectance of surfaces.
3. For materials, coatings and optics.
4. Includes tester, standards and manual.
5. Measures reflectance properties.
FAQ
Q1: What scenarios is this tester used for?
A: It measures surface reflectance of materials, coatings, films and optical parts under standardized geometry for QC. It is used in laboratory, production and field settings, and our team can recommend a suitable configuration for your specific application.
Q2: What standards does it comply with?
A: It follows ISO, ASTM and related GB/T reflectance methods, with calibration using standards. We confirm the stated performance during final inspection and can supply a certificate of conformity together with supporting documents for audit purposes.
Q3: What is the warranty?
A: It carries a 12 to 24 month warranty covering the unit. Standards are consumables. Damage from misuse is excluded.
Q4: Is it hard to operate?
A: It requires trained staff for geometry and calibration. We provide a manual and training.
Q5: What is the lead time?
A: Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.
Q6: Is calibration required?
A: Performance should be verified periodically using calibrated reference standards, with results logged in the equipment record. Most users perform this check every 6 to 12 months or according to their internal quality schedule. We provide the procedure, reference materials and formal calibration service if required.
Q7: Are consumables universal?
A: Compatible items are single-use consumables designed for this application. They are widely available in standard sizes, and we can supply them directly or confirm the specification so you can source them locally. Ongoing cost is limited to these consumables, and there are no proprietary locked parts.
Q8: Can it be customized?
A: Yes, several configurations are available. Options include geometry, wavelength and data logging. We can discuss further custom requirements, confirm feasibility and advise any effect on the schedule before the order is confirmed.
Q9: Is installation included?
A: No installation is required for this unit. It is ready to run after a simple power connection and the leveling steps shown in the manual. We supply a detailed operation guide and online setup videos, and on-site commissioning can be arranged separately if your facility requires it.
Q10: What samples are compatible?
A: It handles flat samples within the stage and geometry. It is not for non-flat parts without fixtures, transparent targets requiring transmittance mode, or samples beyond the stage.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.