Introduction

A microbial identification mass spectrometer is an analytical instrument used to identify the microorganisms, such as the bacteria, the yeast, and the fungi, by the mass spectrometry, and it is used in the clinical microbiology, the food, the pharmaceutical, and the research laboratories for the rapid and the accurate identification of the microorganisms. The microbial identification mass spectrometer, typically a MALDI-TOF (matrix-assisted laser desorption/ionization time-of-flight) mass spectrometer, measures the mass spectrum of the proteins of the microorganism, in which the sample is mixed with the matrix, applied to the target plate, and ionized by the laser, and the time-of-flight of the ions is measured, providing a protein fingerprint or the mass spectrum, which is compared with the reference database to identify the species; the microbial identification mass spectrometer provides a rapid identification, within minutes, with a high accuracy, and it is used for the identification of the clinical isolates, for the identification of the food and the water isolates, for the identification of the environmental isolates, for the epidemiological typing, for the detection of the resistance markers, and for many other applications; the instrument consists of the mass spectrometer, the sample preparation, the database, and the analysis software, and it provides features such as the automated operation and the data management; the microbial identification mass spectrometer is an essential instrument in the modern microbiology laboratory. Microbial identification mass spectrometers are used in the clinical microbiology laboratories, in the food and the beverage industry, in the pharmaceutical industry, in the research, and for many other applications. With their rapid identification, microbial identification mass spectrometers are essential for the microbiological analysis.

Microbial Identification Mass Spectrometer LRMS-T2010

Microbial Identification Mass Spectrometer LRMS-T2010



Microbial Identification Mass Spectrometer processes 96 samples with results available in under 5 minutes. It operates at 1 to 2 GHz acquisition frequency for efficient microbial identif...

Standards

European Pharmacopoeia 2.2.25-Spectrophotometry, ultraviolet and visible

ASTM E275-08(2022)-Standard Practice for Describing and Measuring Performance of Ultraviolet, Visible, and Near-Infrared Spectrophotometers

Complies with the above standards, but is not limited to them.

Features

1. Microbial identification mass spectrometer.

2. MALDI-TOF system identifying microorganisms.

3. For clinical and microbiology laboratories.

4. Includes system, software, targets and manual.

5. Identifies microbes by mass profiles.

FAQ

Q1: What scenarios is this system used for?

A: It identifies bacteria and fungi by matching protein mass profiles against a database using MALDI-TOF mass spectrometry. It is used in laboratory, production and field settings, and our team can recommend a suitable configuration for your specific application.

Q2: What standards does it comply with?

A: It follows clinical laboratory, medical device and ISO 15189-related requirements and GB/T standards, with the database validated. The relevant parameters are verified during final inspection before shipment, and compliance documentation or test reports can be provided on request for your quality records.

Q3: What is the warranty?

A: It carries a 12 to 24 month warranty covering the instrument. Reagents and targets are consumables. Damage from misuse is excluded.

Q4: Is it hard to operate?

A: It requires trained staff for sample prep, calibration and database use. We provide a manual, installation and training.

Q5: What is the lead time?

A: Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.

Q6: Is calibration required?

A: Performance should be verified periodically using calibrated reference standards, with results logged in the equipment record. Most users perform this check every 6 to 12 months or according to their internal quality schedule. We provide the procedure, reference materials and formal calibration service if required.

Q7: Are consumables universal?

A: Reagents and targets are system-specific. Ongoing cost includes reagents and database updates.

Q8: Can it be customized?

A: Yes, several configurations are available. Options include database libraries, automation and LIMS connectivity. We can discuss further custom requirements, confirm feasibility and advise any effect on the schedule before the order is confirmed.

Q9: Is installation included?

A: No installation is required. The unit is delivered fully assembled and factory tested, so you only need to place it on a level surface, connect power and follow the quick-start guide. An illustrated manual and setup video are included, and our engineers provide remote guidance if needed.

Q10: What samples are compatible?

A: It handles cultured microbial isolates prepared for the system. It is not for direct mixed-sample identification without preparation, non-microbial targets, or organisms absent from the validated database.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.

Inquiry