Introduction

A rocker shaker is a laboratory instrument used to mix and agitate samples by a gentle rocking motion, and it is used in biology, chemistry, clinical, and molecular biology laboratories for the mixing of samples, the staining of the gels and the blots, the hybridization, and many other applications. The rocker shaker consists of a base with a motor and a platform that holds the containers, and the platform rocks back and forth, producing a gentle wave-like motion, and the motion is suitable for the mixing of the samples that require a gentle agitation, such as the staining of the gels and the blots, the washing of the membranes, the hybridization, and the culture of the cells; the rocker shaker provides a variable speed and a low angle of the rocking, and it is available in various sizes, with platforms for the different containers, from the tubes and the plates to the trays and the bottles, and it may include a timer and a digital display, and it is compact and quiet; the rocker shaker is used for the staining and the destaining of the gels, for the washing and the incubation of the blots, for the hybridization, for the mixing of the samples in the tubes and the plates, for the gentle agitation of the cell cultures, and for many other applications, and it is an essential instrument in the molecular biology laboratory. Rocker shakers are used in molecular biology and biochemistry for the blotting and the staining, in clinical laboratories, in the pharmaceutical industry, in the food industry, and for many other applications. With their gentle rocking, rocker shakers are essential for gentle mixing in the laboratory.

Rocker Shaker LRSR-T2014

Rocker Shaker LRSR-T2014



Rocker Shaker offers a variable speed range of 5 to 80 rpm, allowing for gentle to moderate mixing, suitable for a wide range of applications. It includes a programmable timer for flexib...
Rocker Shaker LRSR-T2013

Rocker Shaker LRSR-T2013



Rocker Shaker offers a variable speed range of 5 to 80 rpm, enabling gentle to moderate rocking motion for diverse laboratory mixing applications. The wear-resistant articulated rotating...
Rocker Shaker LRSR-T2012

Rocker Shaker LRSR-T2012



Rocker Shaker has a maximum loading capacity of 2 kg and speed range of 10 to 80 rpm. It features an display for precise adjustment and monitoring of speed and time function. The shaker ...
Rocker Shaker LRSR-T2011

Rocker Shaker LRSR-T2011



Rocker Shaker supports maximum loading capacity of 5 kg for efficient mixing. Its gentle rocking motion prevents sample degradation while promoting uniform agitating efficiency. Includes...
Rocker Shaker LRSR-T2010

Rocker Shaker LRSR-T2010



Rocker Shaker offer speed ranging from 10rpm to 70rpm for gentle mixing of sensitive samples. Its digital display shows real-time parameters, enhancing user convenience and operational c...

Standards

IEC 61010-2-051:2018-Particular requirements for laboratory equipment for mixing and stirring

Complies with the above standards, but is not limited to them.

Features

1. Rocker shaker for gentle rocking and mixing.

2. Benchtop rocker with tilting platform and adjustable speed.

3. For blots, gels, staining and general mixing.

4. Includes shaker, platform, controls and manual.

5. Provides consistent rocking motion for samples.

FAQ

Q1: What scenarios is a rocker used for?

A: It provides gentle tilting motion for Western blots, staining, washing and general mixing, keeping solutions moving uniformly over membranes or gels.

Q2: What standards does it comply with?

A: It follows IEC 61010 and IEC 61326 for safety and EMC and related GB/T standards, with speed verified.

Q3: What is the warranty?

A: The rocker carries a 12 to 24 month warranty covering drive and controls. Platforms are wear parts. Damage from spills or overloading is excluded.

Q4: Is it hard to operate?

A: Operation is simple: place samples, set speed and start. We provide a manual and guidance.

Q5: What is the lead time?

A: Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.

Q6: Is calibration required?

A: Performance should be verified periodically using calibrated reference standards, with results logged in the equipment record. Most users perform this check every 6 to 12 months or according to their internal quality schedule. We provide the procedure, reference materials and formal calibration service if required.

Q7: Are consumables universal?

A: Platform mats are model-specific, while vessels are standard. Ongoing cost is minimal.

Q8: Can it be customized?

A: Yes, several configurations are available. Options include platform size, speed, tilt angle, stacking and cold-room compatibility. We can discuss further custom requirements, confirm feasibility and advise any effect on the schedule before the order is confirmed.

Q9: Is installation included?

A: No installation is required for this unit. It is ready to run after a simple power connection and the leveling steps shown in the manual. We supply a detailed operation guide and online setup videos, and on-site commissioning can be arranged separately if your facility requires it.

Q10: What samples are compatible?

A: It handles secured trays, blots and vessels within load. It is not for unsecured containers, high-speed orbital needs, or excessive loads.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.

Inquiry