Introduction
Rocking shakers are specialized laboratory instruments designed to provide gentle and consistent agitation for samples in a rocking or tilting motion. These shakers are commonly used in various life science and cell culture applications, including hybridization, staining, and incubation, where maintaining a low-shear, uniform mixing environment is crucial. They feature a platform that rocks back and forth, ensuring that samples within flasks, culture plates, or other containers receive even and consistent agitation. Rocking shakers often offer adjustable speed and tilt angle settings to accommodate different experimental requirements.
Rocking Shaker T-RSK-S2104
Rocking Shaker T-RSK-S2103
Rocking Shaker T-RSK-S2102
Rocking Shaker T-RSK-S2101
Rocking Shaker T-RSK-S2100
Multi-Function Rocking Shaker T-MRS-1100
Digital Rocking Shaker T-RS-S2101
Digital Rocking Shaker T-RS-S2100
Rocking Shaker T-S211RS
Rocking Shaker operates at a speed range of 1 to 70 rpm with an adjustable tilt angle from 0 to 10°. It features a user-friendly LCD screen, providing clear visibility of operating condi...
Rocking Shaker T-S220RS
Rocking Shaker features rocking motion with a speed range of 0 to 60 rpm and an adjustable tilt angle from 0 to 15°. It combines a step motor with PID temperature control for precise mot...
Rocking Shakers T-S210RS
Rocking Shaker is a benchtop unit that creates a perfectly smooth see-saw wave motion for uniform mixing within culture flasks, petri dishes, etc. It features an adjustable tilt angle for...
Standards
IEC 61010-2-051:2018-Particular requirements for laboratory equipment for mixing and stirring
Complies with the above standards, but is not limited to them.
Features
1. Maintenance-free drive maintains consistent motion over long runs.
2. Brushless motor provides quiet, maintenance-free operation.
3. Wide speed range handles gentle re-suspension through vigorous aeration.
4. Interchangeable platforms, heads or paddles fit many vessels.
5. Adjustable speed and time suit a range of mixing tasks.
FAQ
What is the Rocking Shaker mainly used for?
The Rocking Shaker is used to mix, agitate, blend or aerate samples and media. It supports sample preparation, culturing, extraction and quality control in biology, chemistry, food, pharmaceutical and clinical laboratories.
What standards does the Rocking Shaker comply with?
The unit is designed with reference to IEC 61010 electrical safety and relevant GB/T standards for laboratory mixing equipment. Procedures should follow the applicable methods. Compliance documentation can be provided on request.
What warranty comes with the Rocking Shaker?
The complete unit carries a 12-month warranty from delivery, covering the main body, core components and controller against manufacturing defects. Consumables and wearing parts such as filters, seals and probes are not covered. Damage from misuse, improper power or unauthorised repair is excluded, and extended warranty can be quoted.
Will staff need special training?
No advanced specialist skills are needed for standard operation, though correct sample handling and safety practice should be followed. We supply a detailed manual and start-up support. For multi-user or regulated sites, a short staff training session can be arranged.
How long does delivery usually take?
Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.
Does the Rocking Shaker need calibration or verification?
The unit is calibrated and tested before delivery. For ongoing accuracy, verify it against traceable reference standards every 6 to 12 months, or according to the laboratory quality schedule. We can arrange calibration service and certificates where required.
Where do we get replacement parts?
No proprietary consumable contract is required; standard parts are available from us and common laboratory suppliers. Our service team can supply a recommended parts list for the model. Most routine spares are held for quick delivery.
Can it be adapted to our requirements?
Yes, common options include different ranges, voltages, accessories, interfaces and capacity or size configurations. We confirm feasibility, specifications and any delivery impact before order confirmation. Custom requirements are reviewed case by case.
How is the Rocking Shaker commissioned?
Benchtop and standard units typically require only placement and connection before use, while larger systems may need professional commissioning. We confirm the installation requirements at order stage. On-site service and training can be provided if needed.
What should be avoided when using the Rocking Shaker?
Do not exceed the rated load or speed, run unbalanced or unsecured vessels, or use incompatible media. Secure containers and use slow start. Follow laboratory safety rules.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.