Introduction

A platelet incubator is a laboratory instrument used to store and agitate platelets at a controlled temperature for transfusion medicine, and it is used in blood banks, hospitals, and clinical laboratories for the storage of platelet concentrates before transfusion. Platelets are stored at a controlled temperature, typically 20-24 degrees Celsius, with continuous gentle agitation, which maintains the viability and the function of the platelets during the storage, and the platelet incubator provides this environment, with a temperature-controlled chamber, a gentle agitation mechanism, such as a rocking or rotating platform, and a temperature display and alarm; the platelet incubator holds platelet bags on shelves or trays, and it maintains the temperature within the specified range, and it provides an alarm if the temperature is outside the range, and it may include a built-in agitator or be used with a separate platelet agitator, and it is used for the storage of platelets for up to 5-7 days, depending on the storage conditions and the regulations, and the incubator is available in various sizes, from small models for a few bags to large models for many bags. Platelet incubators are used in blood banks and transfusion services for storing platelet concentrates, in hospitals for transfusion medicine, in clinical laboratories, and for many other applications, and they are essential for the safe storage of platelets. With their controlled storage environment, platelet incubators are essential for transfusion medicine.

Platelet Incubator LPTI-T2013

Platelet Incubator LPTI-T2013



Platelet Incubator provides a controlled environment with a temperature range of 20℃ to 24℃, ideal for the safe and effective storage of platelets. The microprocessor-based controller ...
Platelet Incubator LPTI-T2011

Platelet Incubator LPTI-T2011



Platelet Incubator maintains a stable temperature range of 20 to 24 °C, ensuring optimal storage conditions for platelet preservation. Prevents ice build-up, ensuring consistent tempera...
Platelet Incubator LPTI-T2012

Platelet Incubator LPTI-T2012



Platelet Incubator maintains a stable temperature range of 20 to 24°C, ensuring optimal storage conditions for platelet preservation. It features a continuous agitation system to keep p...
Platelet Incubator LPTI-T2010

Platelet Incubator LPTI-T2010



Platelet Incubator is crafted to maintain a stable temperature range of 20 to 24℃, ensuring optimal storage conditions for platelets. Features a built-in agitator that provides gentle, ...

Standards

ISO 11133:2014-Microbiology of food, animal feed and water-Preparation, production, storage and performance testing of culture media

Complies with the above standards, but is not limited to them.

Features

1. Platelet incubator for storing platelets at controlled temperature.

2. Cabinet maintaining 20-24 C for platelet bags.

3. For blood banks and transfusion services.

4. Includes incubator, shelves, controls and manual.

5. Stores platelets at the required temperature.

FAQ

Q1: What scenarios is this incubator used for?

A: It stores platelet concentrates at 20 to 24 C in blood banks, with some units providing separate agitation or being paired with an agitator.

Q2: What standards does it comply with?

A: It follows blood bank guidance, medical device requirements and related GB/T standards, with temperature verified. The relevant parameters are verified during final inspection before shipment, and compliance documentation or test reports can be provided on request for your quality records.

Q3: What is the warranty?

A: The incubator carries a 12 to 24 month warranty covering controls. Seals and filters are wear parts. Damage from misuse is excluded.

Q4: Is it hard to operate?

A: Operation is simple for trained staff: load bags, set temperature and monitor. We provide a manual and training.

Q5: What is the lead time?

A: Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.

Q6: Is calibration required?

A: We recommend verification against traceable standards at regular intervals, typically every 6 to 12 months, and keeping calibration records for audit purposes. The manual describes the procedure, and reference standards are available from us. Accredited third-party calibration can also be arranged on request.

Q7: Are consumables universal?

A: Filters are model-specific, while bags are standard blood bank products. Ongoing cost is minimal.

Q8: Can it be customized?

A: Yes, several configurations are available. Options include capacity, shelves, alarms and data logging. We can discuss further custom requirements, confirm feasibility and advise any effect on the schedule before the order is confirmed.

Q9: Is installation included?

A: No installation is required for this unit. It is ready to run after a simple power connection and the leveling steps shown in the manual. We supply a detailed operation guide and online setup videos, and on-site commissioning can be arranged separately if your facility requires it.

Q10: What products are compatible?

A: It handles platelet bags within capacity. It is not for refrigerated blood products, non-standard containers, or storage requiring continuous agitation unless paired with an agitator.