Introduction
A semi automatic microtome is a microtome with the semi-automated operation, used for the cutting of the thin sections of the tissue samples for the microscopy, and it is used in the pathology, the histology, the research, and the many other applications. The semi automatic microtome cuts the sections with the manual positioning and the motorized or the manual advance of the specimen block against the knife, and it provides the sections with the uniform thickness; the semi automatic microtome consists of a specimen block holder, a knife holder, an advance mechanism, a section thickness control, and the controls, and it provides features such as the adjustable section thickness; the semi automatic microtome is used for the sectioning of the tissue samples for the histology, for the preparation of the sections for the microscopy, for the pathology, for the research, and for many other applications, and it is an essential instrument in the histology laboratory. Semi automatic microtomes are used in the pathology, in the histology, in the research, in the clinical laboratories, and for many other applications. With their semi-automated operation, semi automatic microtomes are essential for the reliable sectioning.
Semi-T20utomatic Microtome LSAM-T2011
Semi-automatic Microtome provides ultra-fine sectioning with an adjustable thickness from 0.1μm (increments of 0.1μm) for flawless, repeatable results. The microtome gives effortless c...
Semi-T20utomatic Microtome LSAM-T2010
Semi-automatic Microtome uses a streamlined design with extraordinary ergonomic characteristics for comfortable operation while maintaining reproducible precision during sectioning. It i...
Semi-T20utomatic Microtome LSAM-T2011
The Semi-automatic Microtome provides a streamlined design with exceptional ergonomic attributes for comfortable use and repeatable precision during sectioning. It is a rotary microtome ...
Semi-T20utomatic Microtome LSAM-T2010
Semi-automatic Microtome is a semi-automated unit with manual functionality for user convenience. Designed with built-in actuation system for precise tissue slicing, safety alarm system ...
Standards
ISO/TS 23824:2024-Medical laboratories-Guidance on application of ISO 15189 in anatomic pathology
Complies with the above standards, but is not limited to them.
Features
1. Semi-automatic microtome combining motorized feed with manual sectioning.
2. Motorized specimen advance with manual rotary sectioning for convenience and control.
3. Suitable for pathology, histology, biomedical, research and educational labs.
4. Includes microtome body, motorized feed, blade holder, controller and manual.
5. Supports consistent section thickness with manual control for routine histology.
FAQ
Q1: What testing scenarios is this microtome mainly applied to?
A: The semi-automatic microtome is used in pathology laboratories, histology facilities, biomedical research, educational institutions, clinical diagnostics and research to perform tissue sectioning with motorized specimen advance (feed) combined with manual rotary sectioning, providing consistent section thickness with operator control for routine histology and research. It supports routine histopathology sectioning for diagnosis, biomedical research tissue sectioning, educational histology teaching, clinical pathology, and general laboratory tissue sectioning. The semi-automatic design combines the consistency of motorized thickness control with the tactile control of manual sectioning, offering a balance between automation and operator control for routine histology applications. It is essential for pathology, histology, biomedical, research and educational laboratories requiring semi-automatic tissue sectioning with motorized feed and manual sectioning for routine histopathology, biomedical research, educational teaching and clinical diagnostics, where the motorized specimen advance provides consistent section thickness while the manual rotary sectioning offers operator control and tactile feedback, supporting efficient, reliable tissue sectioning for diagnostic pathology, research and education in histology laboratories requiring a balance of automation and manual control.
Q2: What standards does the microtome comply with?
A: The semi-automatic microtome complies with relevant IEC 61010 laboratory electrical safety standards, applicable GB/T standards for histological equipment, and relevant medical device regulations for clinical use. The instrument follows applicable electromagnetic compatibility standards. Blades should be certified for histological use. Users should verify compliance with specific facility requirements for their application, including biosafety for tissue handling.
Q3: What is the warranty period for the whole machine and key components?
A: The whole semi-automatic microtome is covered by a 12-month warranty. The microtome body, motorized feed, controller, blade holder and specimen holder are covered, while blades, disposable blade holders and fuses are consumables or accessories. Damage from improper use, blade damage or unauthorized repair is excluded. Extended service contracts may be available.
Q4: Is this device difficult to operate? Is professional training required?
A: Operation requires trained histology or pathology personnel familiar with tissue sectioning, microtome use and biosafety. We provide operation manuals, training and application support. Proper specimen embedding, blade selection, section thickness setting, motorized feed operation, manual sectioning, blade safety and biosafety procedures are important for quality sections and safe operation.
Q5: What is the typical lead-time for order delivery?
A: Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.
Q6: Is regular calibration required? What is the recommended calibration cycle?
A: Section thickness calibration and verification recommended every 6-12 months. Motorized feed accuracy checked periodically. Blade holder and specimen holder alignment verified. Routine cleaning and lubrication per manufacturer instructions. Full system performance verification annually.
Q7: Are supporting consumables universal?
A: Microtome blades, blade holders, embedding rings and forceps are available from histology suppliers, though compatibility should be verified. Long-term consumable cost depends on sectioning volume and blade type.
Q8: Can I customize parameters or supporting accessories?
A: Customization includes section thickness range, motorized feed speed, blade type, specimen holder size, control features and accessories. Additional blade holders, specimen holders and accessories can be ordered separately. Custom orders extend delivery lead-time.
Q9: Does the purchase include on-site installation and commissioning service?
A: Standard delivery includes the semi-automatic microtome and accessories with an operation manual. On-site installation, calibration and training are not included for standard orders but can be arranged for laboratory setup. Remote guidance is provided.
Q10: What types of samples are compatible with this equipment?
A: The semi-automatic microtome sections fixed, paraffin-embedded tissue samples within the specimen size, section thickness and hardness specification. Different tissue types require specific section thickness (typically 3-5 micrometers for routine histology). Very hard or calcified tissues may require special blades or decalcification. Users should properly embed and trim the tissue block, select appropriate blade type and angle, set correct section thickness via motorized feed, use smooth manual sectioning, follow proper blade handling safety, maintain blade cleanliness, and handle sections carefully for mounting. The microtome should be placed on a stable, vibration-free surface. For clinical pathology, follow proper tissue processing and embedding protocols. The motorized feed should be calibrated for accurate thickness. The blade should be replaced when dull. The specimen should be properly oriented. The mechanism should be cleaned and lubricated regularly. The semi-automatic design is suitable for routine histology; for very high throughput, a fully automatic microtome may be more appropriate. The handwheel should be operated with consistent motion. Waste should be disposed of per laboratory procedures. The instrument should be used per manufacturer instructions for the motorized feed and manual sectioning functions.