Introduction

An ultrasonic homogenizer, also known as a sonicator, is a laboratory instrument that uses high-intensity ultrasonic waves to homogenize, disrupt, mix, and process samples, and it is widely used in biotechnology, biology, chemistry, pharmaceutical, food, and materials laboratories for cell disruption, particle dispersion, emulsification, and sample preparation. The instrument consists of an ultrasonic generator that produces high-frequency electrical signals, typically at 20-25 kHz, and a transducer and probe, also called a horn or sonotrode, that converts the electrical energy into mechanical vibrations; the probe is immersed in the sample, and the vibrations create cavitation, in which microscopic bubbles form and collapse violently, generating intense local forces and high shear that disrupt cells and tissues, break up particles and aggregates, and mix and homogenize the sample, and the instrument allows control of the ultrasonic power, time, and duty cycle, and the probe is available in various sizes for different volumes. Ultrasonic homogenizers are used for cell lysis and protein extraction, for DNA and RNA fragmentation, for preparing emulsions and dispersions, for dissolving solids, for reducing particle size, for degassing, for accelerating reactions, for extracting compounds, and for many other applications, in research, clinical, and industrial laboratories, and they are available in various power ratings, from small benchtop models to large industrial units, with features such as digital displays, programmable processing, and temperature monitoring. With their powerful processing capability, ultrasonic homogenizers are essential instruments for sample preparation and processing.

Ultrasonic Homogenizer (Sonicator) LUHS-T2012

Ultrasonic Homogenizer (Sonicator) LUHS-T2012



Ultrasonic Homogenizer (Sonicator) offers adjustable ultrasonic power ranging from 5 to 650 watts, ensuring reliable performance. It is equipped with advanced a 4.3-inch touch screen, al...
Multi-T20hannel Ultrasonic Homogenizer LUHS-T2010

Multi-T20hannel Ultrasonic Homogenizer LUHS-T2010



Multi-Channel Ultrasonic Homogenizer operates at a frequency range of 20 to 25 KHz with a temperature test range of 0 to 100 ℃. Its ultrasonic generator and transducer assembly ensure r...
Ultrasonic Homogenizer (Sonicator) LUHS-T2016

Ultrasonic Homogenizer (Sonicator) LUHS-T2016



Ultrasonic Homogenizer (Sonicator) is a table-top, multi-function & multi-purpose unit, comes with 1500 ml of process capacity and adjustable ultrasonic power of 20 to 1800 W. Features 0...
Ultrasonic Homogenizer (Sonicator) LUHS-T2014

Ultrasonic Homogenizer (Sonicator) LUHS-T2014



Ultrasonic Homogenizer (Sonicator) is a table-top, multi-function & multi-purpose unit, comes with 800 ml of process capacity and adjustable ultrasonic power of 10 to 1000 W. Features 0 ...
Ultrasonic Homogenizer (Sonicator) LUHS-T2015

Ultrasonic Homogenizer (Sonicator) LUHS-T2015



Ultrasonic Homogenizer (Sonicator) is a table-top, multi-function & multi-purpose unit, comes with 1200 ml of process capacity and adjustable ultrasonic power of 20 to 1200 W. Features 0...
Ultrasonic Homogenizer (Sonicator) LUHS-T2010

Ultrasonic Homogenizer (Sonicator) LUHS-T2010



Ultrasonic Homogenizer (Sonicator) is a table-top, multi-function & multi-purpose unit, comes with 150 ml of process capacity and adjustable ultrasonic power of 2 to 150 W. Features 0 to...
Ultrasonic Homogenizer (Sonicator) LUHS-T2011

Ultrasonic Homogenizer (Sonicator) LUHS-T2011



Ultrasonic Homogenizer (Sonicator) is a table-top, multi-function & multi-purpose unit, comes with 250 ml of process capacity and adjustable ultrasonic power of 5 to 250 W. Features 0 to...
Ultrasonic Homogenizer (Sonicator) LUHS-T2013

Ultrasonic Homogenizer (Sonicator) LUHS-T2013



Ultrasonic Homogenizer (Sonicator) is a multifunctional, tabletop homogenizer utilized to disrupt, disperse, emulsify, and homogenize samples, with an ultrasonic power range of 10 to 900...
Ultrasonic Homogenizer (Sonicator) LUHS-T2020

Ultrasonic Homogenizer (Sonicator) LUHS-T2020



Ultrasonic Homogenizer (Sonicator) is a 2000 W ultrasound probe sonicator, can handle 2 touch screen operation panel, microcomputer control, adjustable ultrasonic power and time, it offe...
Ultrasonic Homogenizer (Sonicator) LUHS-T2017

Ultrasonic Homogenizer (Sonicator) LUHS-T2017



Ultrasonic homogenizer (Sonicator) offers adjustable power from 1000 to 3000W. It can handle sample volumes between 250 and 5000 mL, depending on the rod used. Our ultrasonic homogenize...

Standards

IEC 61010-2-051:2018-Particular requirements for laboratory equipment for mixing and stirring

Complies with the above standards, but is not limited to them.

Features

1. Ultrasonic homogenizer (sonicator) for direct probe homogenization and cell lysis.

2. High-intensity ultrasonic probe for efficient sample disruption and homogenization.

3. Suitable for biological, chemical, pharmaceutical, food, nanomaterial and research labs.

4. Includes generator, transducer, probe, stand, controller and operation manual.

5. Supports cell lysis, emulsification, dispersion, particle size reduction and extraction.

FAQ

Q1: What testing scenarios is this sonicator mainly applied to?

A: The ultrasonic homogenizer (sonicator) is used in biological research, chemical processing, pharmaceutical development, food analysis, nanomaterial synthesis, environmental testing and research laboratories to perform high-intensity ultrasonic homogenization, cell lysis, emulsification, dispersion and extraction using a direct probe for efficient sample disruption. It supports microbial and mammalian cell lysis for DNA/RNA/protein extraction, emulsification of oil-water mixtures, nanoparticle dispersion and size reduction, pharmaceutical sample preparation, food sample homogenization, chemical extraction and reaction acceleration, and environmental sample processing. The direct probe provides high-intensity ultrasonic energy, enabling efficient processing of difficult samples. It is essential for biological, chemical, pharmaceutical, food, nanomaterial and research laboratories requiring high-intensity ultrasonic homogenization for cell lysis, emulsification, dispersion, particle size reduction, extraction and sample preparation, where the direct probe provides high-intensity ultrasonic energy for efficient disruption of cells, tissues and materials, supporting molecular biology, nanomaterial synthesis, pharmaceutical development, food analysis and chemical processing in research and industrial applications requiring powerful, versatile ultrasonic sample processing.

Q2: What standards does the sonicator comply with?

A: The ultrasonic homogenizer complies with relevant IEC 61010 laboratory electrical safety standards and applicable GB/T standards for laboratory equipment. Biological and clinical applications follow good laboratory practice and applicable biosafety guidelines. The instrument complies with relevant electromagnetic compatibility and noise standards. Users should verify compatibility with their specific sample types and protocols.

Q3: What is the warranty period for the whole machine and key components?

A: The whole sonicator is covered by a 12-month warranty. The generator, transducer, controller and housing are covered, while probes, tips, stands and fuses are consumables or accessories. Damage from improper use, probe damage or unauthorized repair is excluded. Extended service contracts are available.

Q4: Is this device difficult to operate? Is professional training required?

A: Operation requires trained laboratory personnel familiar with ultrasonic homogenization, sample handling and safety. We provide operation manuals, training and application support. Proper probe selection, parameter setting, sample handling, cooling (to prevent overheating) and safety procedures are important for effective homogenization and safe operation.

Q5: What is the typical lead-time for order delivery?

A: Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.

Q6: Is regular calibration required? What is the recommended calibration cycle?

A: Ultrasonic power and frequency verification recommended every 6-12 months. Probe condition (wear, cracks) checked before each use. Transducer condition verified periodically. Routine cleaning of probe after each use. Full system performance check annually. Probe replacement when worn or damaged.

Q7: Are supporting consumables universal?

A: Probes, tips, stands and accessories are available from specialized suppliers, though compatibility with the generator should be verified. Long-term consumable cost depends on usage and probe wear.

Q8: Can I customize parameters or supporting accessories?

A: Customization includes power output, probe size and material, frequency, stand type, control features, pulse mode and accessories. Additional probes, stands and accessories can be ordered separately. Custom orders extend delivery lead-time.

Q9: Does the purchase include on-site installation and commissioning service?

A: Standard delivery includes the ultrasonic homogenizer and accessories with an operation manual. On-site installation, calibration and training are not included for standard orders but can be arranged for laboratory setup. Remote guidance is provided.

Q10: What types of samples are compatible with this equipment?

A: The ultrasonic homogenizer processes liquid samples, suspensions, tissues and materials in compatible vessels within the power, probe and sample volume specification. Different sample types require different probes, power levels and processing times. Highly viscous samples may require higher power or longer processing. Heat-sensitive samples require pulse mode and ice bath cooling. Users should select appropriate probe size for the sample volume, optimize parameters (power, time, pulse) for the sample type, use pulse mode to prevent overheating, keep the probe submerged to prevent aerosolization, clean the probe thoroughly between samples to prevent cross-contamination, follow proper biosafety procedures for pathogenic samples, and wear hearing protection as sonicators can be loud. The probe tip can erode over time and should be inspected regularly. For sterile applications, the probe should be autoclaved or disinfected before use. The sample should be processed in an appropriate container on ice or in a cooling bath to prevent thermal degradation of heat-sensitive materials.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.

Inquiry