Introduction
A flash point tester is an instrument used to measure the flash point of the flammable liquids, which is the lowest temperature at which the vapors ignite, and it is used in the petroleum, the fuel, the chemical, the safety, and the many other industries. The flash point tester measures the flash point by the heating of the sample at a controlled rate and the application of an ignition flame at the intervals, with the closed cup or the open cup methods, following the standard test methods, such as the ASTM and the ISO standards; the flash point tester consists of a test cup, a heating system, a temperature control and a measurement system, an ignition source, and the observation, and it provides the flash point, with features such as the digital temperature display; the flash point tester is used for the measurement of the flash point of the fuels, the solvents, the lubricants, and the other flammable liquids, for the safety, for the classification, for the quality control, and for many other applications, and it is an essential instrument for the flammability testing. Flash point testers are used in the petroleum industry, in the fuel industry, in the chemical industry, in the safety, and for many other applications. With their flash point measurement, flash point testers are essential for the flammability assessment.
Open And Closed Cup Flash Point Tester LOCFT-T2010
Open and Closed Cup Flash Point Tester delivers temperature stability within an ambient range of 0 to 40°C. It features an operating humidity capacity of up to 85% RH allowing dependabl...
Digital Closed Cup Flash Point Tester LCFP-T2010
Digital Closed Cup Flash Point Tester features standardized closed cup of 50.8mm diameter. Ensures safety and reliability with high-precision air valve adjustment system. Equipped with s...
Automatic Tag Closed Flash Point Tester LACF-T2011
Automatic Tag Closed Flash Point Tester features a temperature range of -35℃ to 105℃, accommodating a wide variety of liquid samples. It is equipped with advanced an external cooling s...
Automatic PMCC Flash Point Tester LCFP-T2011
Automatic Flash Point Tester offers a measurement range from ambient to 300℃ with a resolution of 0.1℃. It features a light-touch coloured that enables easy parameter settings. The tes...
Automatic COC Flash Point & Fire Point Tester LOFP-T2011
Automatic Flash Point & Fire Point Tester measures ignition of liquid vapor and its burning temperature from 79℃ to 370℃. It features fast heating and cooling cycles enhance testing ef...
PMCC Flash Point Tester LCFP-T2015
Flash Point Tester measures ignition of liquid at temperature upto 370℃. It features user-friendly 7" color touch screen interface for easy operation. Equipped with automatic test comp...
Cleveland Open Cup Flash Point Tester LOFP-T2011
Cleveland Open Cup Flash Point Tester allows temperature measurements from room temperature up to 400℃ with a high resolution. It features electronic ignition with a controlled flame si...
Manual PMCC Flash Point Tester LCFP-T2010
Manual Flash Point Tester operates covering a temperature range of RT to 370℃. It has a temperature simulation function tracks the temperature rise curve over time. The heating power is...
Automatic PMCC Flash Point Tester LCFP-T2013
Automatic Flash Point Tester can determine the flash point and ignition point in the measuring range of 40 ℃ to 350 ℃. Enhanced with a power failure memory function. It can store up to...
Automatic PMCC Flash Point Tester LCFP-T2012
Automatic Flash Point Tester features a temperature range of ambient to 230℃. It features an 8-inch high-definition capacitive screen that offers a user-friendly interface. The tester i...
Automatic PMCC Flash Point Tester LCFP-T2014
Automatic Flash Point Tester conforms to GB/T6536 and D86 standards for petroleum product distillation testing. It is a double-unit tester with a condenser pipe reaching a minimum of 0℃...
Automatic COC Flash & Fire Point Tester LOFP-T2010
Our is deliberately furnished to determine both flash point and fire point. It has a wide range of applications with a great market value. It is designed as per the standard D92, ISO2592...
Automatic Cleveland Open Cup Flash Point Tester LOFP-T2012
Automatic Cleveland Open Cup Flash Point Tester operates efficiently within an ambient temperature range of 10°C to 40°C and a relative humidity of up to 80%. It allows presetting of f...
Open Cup Flash Point Tester LOFP-T2010
It is designed with higher precision and perfection to meet its wide range of applications. It is incorporated with advanced and reasonable temperature control features. This petroleum t...
Automatic Tag Closed Flash Point Tester LACF-T2010
Automatic Tag Closed Flash Point Tester is a highly automated machine with -50°C lowest flash point and simple operations. Used to determine flash point of liquids with viscosity below ...
Standards
ISO 2719:2025-Determination of flash point-Pensky-Martens closed cup method
ASTM D93-25-Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester
ISO/TR 29662:2020-Petroleum products and other liquids-Guidance for flash point and combustibility testing
Complies with the above standards, but is not limited to them.
Features
1. Flash point tester for determining the fire hazard of petroleum products and chemicals.
2. Available in open cup or closed cup configurations for different sample types.
3. Precision heating control with standardized ignition source for reproducible results.
4. Suitable for petroleum, chemical, pharmaceutical and quality control laboratories.
5. Includes test cup, heating apparatus, ignition source, thermometer and controller.
FAQ
Q1: What testing scenarios is this tester mainly applied to?
A: The flash point tester is used in petroleum refineries, chemical plants, pharmaceutical manufacturing, paint and coating production, transportation safety and regulatory agencies to determine the flash point of liquids and solids, indicating the lowest temperature at which vapors ignite. It supports fuel specification testing, solvent classification, paint and coating safety assessment, chemical product characterization, transportation hazard classification and quality control. Flash point is a critical safety parameter for handling, storage and transportation of flammable materials, determining the appropriate hazard class and safety precautions. It is essential for laboratories and production facilities requiring reliable flash point determination to ensure product safety, comply with transportation regulations, meet product specifications and protect workers and facilities from fire hazards associated with flammable liquids and chemicals.
Q2: What standards does the tester comply with?
A: The test method follows ASTM D92 for Cleveland open cup, ASTM D93 for Pensky-Martens closed cup, ASTM D56 for Tag closed cup, ISO 2592, ISO 2719 and corresponding GB/T methods. The instrument complies with relevant laboratory safety standards. Test cup dimensions and heating rate should follow the standard specification.
Q3: What is the warranty period for the whole machine and key components?
A: The heating apparatus and controller are covered by a 12-month warranty. The test cup, thermometer and ignition source are consumables or accessories excluded from warranty. Damage from improper heating rate, sample spillage or unauthorized repair is excluded.
Q4: Is this device difficult to operate? Is professional training required?
A: Operation requires trained laboratory personnel familiar with flash point testing and fire safety. We provide an operation manual and remote guidance. Proper sample filling, heating rate control and ignition source application are important for accurate results. Testing should be performed in a well-ventilated area away from drafts.
Q5: What is the typical lead-time for order delivery?
A: Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.
Q6: Is regular calibration required? What is the recommended calibration cycle?
A: Temperature calibration against a reference thermometer recommended every 6-12 months. Heating rate verification periodically. Full method verification with certified flash point reference materials recommended for accredited laboratories.
Q7: Are supporting consumables universal?
A: Test cups, thermometers and ignition gas are available from laboratory suppliers, though cup dimensions should match the standard method. Long-term consumable cost is low.
Q8: Can I customize parameters or supporting accessories?
A: Customization includes cup type (open or closed), automation level, maximum temperature and ignition source type. Additional cups and accessories can be ordered separately. Custom orders extend delivery lead-time.
Q9: Does the purchase include on-site installation and commissioning service?
A: Standard delivery includes the apparatus and accessories with an operation manual. Remote commissioning guidance is provided. On-site service is not included for standard orders.
Q10: What types of samples are compatible with this equipment?
A: The tester measures flash point of petroleum products, solvents, chemicals and other flammable materials within the method range. Sample type determines the appropriate cup method (open or closed). Very low flash point samples require closed cup methods. Highly volatile or contaminated samples may produce inconsistent results. Users should follow proper safety procedures including avoiding drafts and having fire safety equipment available. The appropriate standard method should be selected based on sample type and expected flash point range.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.