Introduction

A bomb calorimeter is an instrument used to measure the heat of combustion of the substances, such as the fuels, the foods, and the chemicals, by the combustion of the sample in a bomb under the oxygen, and it is used in the fuel, the food, the chemistry, the research, and the many other applications. The bomb calorimeter consists of a bomb vessel, which is filled with the oxygen and contains the sample, a calorimeter vessel with the water, a stirring system, a temperature measurement system, and the ignition system, and it measures the temperature rise of the water caused by the combustion of the sample, which is used to calculate the heat of combustion; the bomb calorimeter is used for the measurement of the calorific value of the fuels, for the measurement of the energy content of the foods, for the measurement of the heat of combustion of the chemicals, for the research, for the quality control, and for many other applications, and it is available in various configurations; the bomb calorimeter is an essential instrument for the calorimetry. Bomb calorimeters are used in the fuel industry, in the food industry, in the chemistry laboratories, in the research, and for many other applications. With their combustion, bomb calorimeters are essential for the calorific value measurement.

Automatic Bomb Calorimeter LABC-T2010

Automatic Bomb Calorimeter LABC-T2010



Automatic Bomb Calorimeter offers a heat capacity of 50,000 J/K and ensures accurate calibration using a reference calorific value for every 1°C increase. Equipped with a built-in cooli...
Automatic Bomb Calorimeter LABC-T2011

Automatic Bomb Calorimeter LABC-T2011



Automatic Bomb Calorimeter offers a precise measurement range from 0 to 50,000 J. It employs a 250 ml bomb and the isoperibol test method for accurate analysis. Our automatic bomb calori...
Automatic Bomb Calorimeter LABC-T2010

Automatic Bomb Calorimeter LABC-T2010



Automatic Bomb Calorimeter is capable of holding a bomb volume of 250 ml and delivers quick results within 10 minutes. It features a fully automatic bomb raising and lowering system. The...
Oxygen Bomb Calorimeter LBC-T2024

Oxygen Bomb Calorimeter LBC-T2024



Oxygen Bomb Calorimeter has a heat capacity of 10,500 J/K and supports a bomb volume of 300 ml. It includes operation and troubleshooting instructions and provides automatic voice report...
Oxygen Bomb Calorimeter LBC-T2023

Oxygen Bomb Calorimeter LBC-T2023



Oxygen Bomb Calorimeter offers an oxygen bomb capacity of 300 ml with 8,000 to 40,000 J/K thermal capacity. It is equipped with advanced a color touch display and an intuitive English-la...
Automatic Bomb Calorimeter LABC-T2012

Automatic Bomb Calorimeter LABC-T2012



Automatic Bomb Calorimeter operates within a temperature range of 5℃ to 35℃ and a relative humidity of up to 85%. It features a semiconductor refrigeration system that adjusts refriger...
Oxygen Bomb Calorimeter LBC-T2020

Oxygen Bomb Calorimeter LBC-T2020



Oxygen Bomb Calorimeter operates within a temperature range of 10℃ to 35 ℃. It offers a fully automated testing process that completes the test without manual intervention. Features a ...
Oxygen Bomb Calorimeter LBC-T2022

Oxygen Bomb Calorimeter LBC-T2022



is manufactured with high precision temperature sensor and a high performance A/D converter. The instrument is designed and made as per the International Standards “Test Methods for Hea...
Oxygen Bomb Calorimeter LBC-T2021

Oxygen Bomb Calorimeter LBC-T2021



Oxygen Bomb Calorimeter operates within the temperature detecting range of 0 to 45°C. It has a heat capacity of about 10500 (J/K), making it ideal for precise energy measurements. The m...
Automatic Bomb Calorimeter LABC-T2010

Automatic Bomb Calorimeter LABC-T2010



Automatic Bomb Calorimeter with removable cover design, automatically detects the refrigerating capacity and balance the circulation system w.r.t. last time caloric value. Need to open t...
Automatic Bomb Calorimeter LABC-T2011

Automatic Bomb Calorimeter LABC-T2011



Automatic Bomb Calorimeter comes with semi-automatic oxygen filling and releasing system. Equipped with blades to achieve high stirring efficiency, and faster heat transfer of oxygen bom...

Standards

ISO 1928:2025-Coal and coke-Determination of gross calorific value

ASTM D5865-Standard Test Method for Gross Calorific Value of Coal and Coke

Complies with the above standards, but is not limited to them.

Features

1. Bomb calorimeter for measuring calorific value of solid and liquid combustible materials.

2. Precision oxygen bomb with temperature measurement for accurate heat of combustion.

3. Suitable for coal, fuel, food, biomass, waste and material calorific value testing.

4. Includes oxygen bomb, calorimeter vessel, temperature sensor, ignition system and controller.

5. Supports isoperibol or adiabatic measurement methods for reproducible results.

FAQ

Q1: What testing scenarios is this calorimeter mainly applied to?

A: The bomb calorimeter is used in coal testing laboratories, fuel quality assessment, food analysis, biomass energy research, waste management, cement manufacturing and research institutions to measure the gross calorific value (heat of combustion) of solid and liquid combustible materials. It supports coal quality grading and trade, fuel oil and biofuel energy content determination, food calorie measurement, biomass fuel evaluation, refuse-derived fuel testing, and material combustion energy characterization. The oxygen bomb method provides precise measurement of total heat released during complete combustion under controlled high-pressure oxygen conditions. It is essential for coal trading, fuel quality control, food nutrition labeling, biomass energy assessment and waste-to-energy facilities where accurate calorific value determination is critical for pricing, process optimization, regulatory compliance and energy content evaluation of combustible materials across multiple industries.

Q2: What standards does the calorimeter comply with?

A: The test method follows ASTM D240 for liquid fuels, ASTM D5865 for coal, ISO 1928 for solid mineral fuels, ISO 9831 for animal feeding stuffs, and corresponding GB/T methods including GB/T 213 for coal. The instrument complies with relevant laboratory safety standards including pressure vessel safety for the oxygen bomb. Calibration should use certified benzoic acid reference standards.

Q3: What is the warranty period for the whole machine and key components?

A: The whole calorimeter is covered by a 12-month warranty. The oxygen bomb, temperature sensor, controller and ignition system are covered, while crucibles, fuses, oxygen and benzoic acid standards are consumables. Damage from improper bomb use, overpressure or unauthorized repair is excluded. Extended service contracts are available.

Q4: Is this device difficult to operate? Is professional training required?

A: Operation requires trained laboratory personnel familiar with calorimetric methods and oxygen bomb safety. We provide an operation manual and remote guidance. Proper sample preparation, bomb assembly, oxygen charging, ignition and result calculation are important for accurate results and safe operation. The oxygen bomb is a pressure vessel and requires careful handling.

Q5: What is the typical lead-time for order delivery?

A: Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.

Q6: Is regular calibration required? What is the recommended calibration cycle?

A: Calibration with certified benzoic acid should be performed periodically, typically monthly or when results drift. Oxygen bomb pressure testing and inspection should follow the manufacturer schedule and pressure vessel safety regulations. Temperature sensor calibration every 6-12 months. Daily verification with a standard sample recommended for accredited laboratories.

Q7: Are supporting consumables universal?

A: Crucibles, ignition fuses, oxygen and benzoic acid standards are available from laboratory suppliers, though bomb-specific parts should be verified. Long-term consumable cost is low to moderate depending on testing volume.

Q8: Can I customize parameters or supporting accessories?

A: Customization includes automation level, number of bombs, temperature measurement method and sample capacity. Additional bombs, crucibles and accessories can be ordered separately. Custom orders extend delivery lead-time.

Q9: Does the purchase include on-site installation and commissioning service?

A: Standard delivery includes the calorimeter and accessories with an operation manual. On-site installation, calibration and training are not included for standard orders but can be arranged for testing laboratory setup projects. Remote guidance is provided.

Q10: What types of samples are compatible with this equipment?

A: The calorimeter measures calorific value of solid and liquid combustible materials within the sample weight and energy range. Highly volatile samples require special handling to prevent loss before combustion. Explosive or highly reactive materials require special precautions. Users should follow proper sample preparation, use certified benzoic acid for calibration, ensure proper oxygen charging pressure, inspect the oxygen bomb regularly for safety, and follow pressure vessel regulations for periodic hydrostatic testing. Proper personal protective equipment should be worn during bomb handling and ignition.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.

Inquiry