Introduction
A spectrometer is an analytical instrument used to measure the interaction of the light and the other electromagnetic radiation with the matter, over the specified wavelength or the energy ranges, and it is used in the chemistry, the physics, the biology, the environmental, the materials, and the many other applications. The spectrometer separates the light into its component wavelengths by the dispersion element, such as the prism or the grating, and it measures the intensity of the light at each wavelength, providing the spectrum, and it is used for the identification and the quantification of the substances, with the various types, including the UV-visible, the infrared, the fluorescence, the atomic, and the mass spectrometers; the spectrometer consists of an entrance slit, a dispersion element, the optics, a detector, and a control and a data analysis system, and it provides features such as the wavelength scanning and the spectral analysis; the spectrometer is used for the qualitative and the quantitative analysis, for the measurement of the concentration, for the identification of the compounds, for the analysis of the materials, for the quality control, for the research, and for many other applications, and it is available in various configurations, for the different spectral ranges; the spectrometer is an essential analytical instrument in the modern laboratories. Spectrometers are used in the chemistry and the physics laboratories, in the environmental monitoring, in the materials science, in the industry, and for many other applications. With their spectral measurement, spectrometers are essential for the analysis of the substances.
XRF-Spectrometer LXRF-T2011
-Spectrometer is a down lighting styled device, testing samples of different shapes with a repeatability of 0.05%. Equipped with high-resolution detector for enhancing the preciseness of...
XRF-Spectrometer LXRF-T2010
Spectrometer operates at 15°C to 30°C and support trace level measurement with 1ppm detection limit for accurate elemental analysis. Its automatic sample changer accelerates throughpu...
ICP Spectrometer LICP-T2012
Spectrometer detects micro and macro elements using argon plasma with an analyzing rate of 10 elements per minute. Results can be achieved with lower levels of detection for qualitative ...
ICP Spectrometer LICP-T2011
Spectrometer detects micro and macro elements using argon plasma with an analyzing rate of 15 elements per minute. Results can be achieved with lower levels of detection for qualitative...
ICP spectrometer LICP-T2010
spectrometer detects trace elements using argon plasma where the atomized liquid sample is injected. With an analyzing rate of 26 elements per minute results can be achieved with lower l...
Atomic Fluorescence Spectrometer LAFS-T2010
Atomic Fluorescence Spectrometer is a microprocessor controlled double-channel, non-dispersive unit used for trace element composition, ultra-trace analysis of Mercury and all other hydr...
Angular Spectrometer LASM-T2010
Angular Spectrometer is a tabletop unit, offers angle measurement accuracy of 1 inch and diopter compensation range of ≥ ± 5 diopters. Incorporated with two verniers at the opposite ed...
Standards
European Pharmacopoeia 2.2.25-Spectrophotometry, ultraviolet and visible
ASTM E275-08(2022)-Standard Practice for Describing and Measuring Performance of Ultraviolet, Visible, and Near-Infrared Spectrophotometers
Complies with the above standards, but is not limited to them.
Features
1. Spectrometer for measuring spectral properties of materials across wavelength ranges.
2. High-resolution optical system with sensitive detector for accurate spectral analysis.
3. Suitable for chemical analysis, material characterization, environmental monitoring and research.
4. Supports absorbance, transmittance, reflectance and emission spectral measurements.
5. Includes optical bench, detector, light source, sample compartment and analysis software.
FAQ
Q1: What testing scenarios is this spectrometer mainly applied to?
A: The spectrometer is used in analytical chemistry, material science, environmental monitoring, pharmaceutical development, food quality control and research laboratories to measure the spectral properties of materials across ultraviolet, visible and near-infrared wavelength ranges. It supports chemical compound identification and quantification, material characterization, color measurement, environmental pollutant analysis, pharmaceutical content testing, food quality assessment and spectral research. The high-resolution optical system provides detailed spectral information for qualitative and quantitative analysis of solid, liquid and gas samples. It is essential for analytical and research laboratories requiring versatile spectral measurement capabilities for chemical analysis, material identification, quality control and scientific research, where detailed spectral information provides insights into molecular composition, material properties and sample characteristics across a wide range of applications and sample types.
Q2: What standards does the spectrometer comply with?
A: The spectrometer supports analytical methods referenced in USP, EP and ChP monographs, ASTM and ISO standards for specific analytes, and relevant GB/T standards for spectrometric analysis. The hardware complies with IEC 61010 laboratory safety standards. Wavelength and absorbance accuracy should be verified with certified reference materials for regulated applications.
Q3: What is the warranty period for the whole machine and key components?
A: The whole spectrometer is covered by a 12-month warranty. The optical system, detector, light source and controller are covered, while lamps, cuvettes and calibration standards are consumables excluded from warranty. Damage from improper use or unauthorized repair is excluded. Extended warranty is available.
Q4: Is this device difficult to operate? Is professional training required?
A: Operation requires trained analysts familiar with spectrometric principles and method execution. We provide operation manuals, application support and training. Routine measurement and spectral scanning can be performed by trained operators with software guidance and standard operating procedures.
Q5: What is the typical lead-time for order delivery?
A: Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.
Q6: Is regular calibration required? What is the recommended calibration cycle?
A: Wavelength and absorbance calibration with certified reference materials is recommended every 6-12 months. Routine verification before each analytical batch for regulated work. Light source replacement follows the manufacturer schedule. Optical alignment check periodically.
Q7: Are supporting consumables universal?
A: Lamps, cuvettes and calibration standards are available from multiple qualified suppliers. Long-term consumable cost is moderate depending on usage and light source type.
Q8: Can I customize parameters or supporting accessories?
A: Customization includes wavelength range, resolution, detector type, sample compartment accessories and software modules. Additional accessories can be ordered separately. Custom orders extend delivery lead-time.
Q9: Does the purchase include on-site installation and commissioning service?
A: Standard delivery includes the spectrometer and accessories with an operation manual. On-site installation and training are not included for standard orders but can be arranged for laboratory setup projects. Remote guidance is provided.
Q10: What types of samples are compatible with this equipment?
A: The spectrometer analyzes liquid, solid and gas samples within the wavelength and measurement range. Sample type determines the appropriate measurement mode and accessory. Highly turbid liquid samples cause scattering errors. Very high absorbance samples should be diluted. Users should select appropriate measurement mode and accessories for each sample type, perform proper baseline correction, allow light source warm-up, and follow calibration and verification procedures to maintain measurement accuracy and traceability.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.