Introduction

FTIR Spectrophotometers provide precise infrared spectral analysis for qualitative and quantitative chemical evaluation. They are designed for high sensitivity and stability using sealed interferometers and optical components. These systems support a wide range of sample types and offer user-friendly software for spectral identification and comparison. Their configurations include high-resolution detectors, durable optical benches, and extensive spectral libraries for accurate results. Our FTIR Spectrophotometers are ideal for laboratories involved in pharmaceutical testing, material analysis, petrochemical research, food safety, and academic applications.

FTIR Spectrophotometer FTS200

FTIR Spectrophotometer FTS200


FTIR Spectrophotometer delivers high spectral accuracy with a 30,000:1 signal-to-noise ratio for precise chemical analysis. It features a sealed Michelson interferometer, gold-coated refl...

Standards

ASTM E1421-99(2021)-Standard Practice for Describing and Measuring Performance of Fourier Transform Mid-Infrared (FT-MIR) Spectrometers: Level Zero and Level One Tests

ASTM E1944-98(2021)-Standard Practice for Describing and Measuring Performance of Laboratory Fourier Transform Near-Infrared (FT-NIR) Spectrometers: Level Zero and Level One Tests

ISO 19702:2024-Guidance for sampling and analysis of toxic gases and vapours in fire effluents using Fourier Transform Infrared (FTIR) spectroscopy

Complies with the above standards, but is not limited to them.

Features

1. Software tools support spectral scans, standard curves and kinetics.

2. Multi-cell or sipper options increase measurement throughput.

3. USB, RS232 or printer options export results and reports.

4. Wide wavelength range covers common analytical applications.

5. Multiple modes support absorbance, transmittance, concentration and kinetics.

FAQ

What is the FTIR Spectrophotometer mainly used for?

The FTIR Spectrophotometer is used to measure absorbance, transmittance or concentration of samples across a defined wavelength range. It supports quantitative analysis, purity checks, kinetics and quality control in chemistry, biology, pharmaceutical and environmental laboratories.

Which standards and regulations apply to the FTIR Spectrophotometer?

The instrument is designed with reference to IEC 61010 electrical safety requirements and relevant GB/T standards for spectrophotometers, including wavelength and photometric accuracy. Procedures should follow applicable standard methods. Compliance documentation can be provided on request.

How long is the warranty period?

We provide a 12-month limited warranty on the instrument and its key working parts. Consumables, accessories and parts subject to normal wear are excluded, as is damage caused by incorrect operation or maintenance. An extended service plan is available on request.

Is the FTIR Spectrophotometer difficult to operate?

The controls are designed for regular laboratory use, so most users become confident after a brief introduction. The manual walks through each step, and common settings can be saved for repeat work. Online or on-site training is available if the site requires it.

How long does delivery usually take?

Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.

How often should the FTIR Spectrophotometer be calibrated?

Regular calibration keeps measurements within the stated accuracy; an annual check is typical, with shorter intervals for heavy or regulated use. Reference standards and procedures are described in the manual. We can quote calibration with certificates.

Where do we get replacement parts?

No proprietary consumable contract is required; standard parts are available from us and common laboratory suppliers. Our service team can supply a recommended parts list for the model. Most routine spares are held for quick delivery.

Can it be adapted to our requirements?

Yes, common options include different ranges, voltages, accessories, interfaces and capacity or size configurations. We confirm feasibility, specifications and any delivery impact before order confirmation. Custom requirements are reviewed case by case.

Do you provide on-site installation?

Most models can be commissioned by following the manual, including positioning, connections, checks and a first test run. Remote guidance is available during start-up. On-site installation, commissioning and training can be arranged separately where required.

What should be avoided when using the FTIR Spectrophotometer?

Do not measure highly corrosive or incompatible samples, use dirty cuvettes or skip blank correction. Verify wavelength and photometric accuracy periodically. Follow laboratory safety rules.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.

Inquiry