Introduction
An open and closed cup flash point tester determines ignition temperature of liquids. It is widely used in petroleum and chemical industries. The system ensures safety classification. It solves inconsistent manual testing. By providing standardized heating methods, it supports flammability evaluation.
Open And Closed Cup Flash Point Tester LOCFT-T2010
Open and Closed Cup Flash Point Tester delivers temperature stability within an ambient range of 0 to 40°C. It features an operating humidity capacity of up to 85% RH allowing dependabl...
Standards
ISO 2719:2025-Determination of flash point-Pensky-Martens closed cup method
ASTM D93-25-Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester
ISO/TR 29662:2020-Petroleum products and other liquids-Guidance for flash point and combustibility testing
Complies with the above standards, but is not limited to them.
Features
1. Open and closed cup flash point tester for determining the lowest temperature at which vapours ignite.
2. Supports both open cup and closed cup test methods for different applications.
3. Precise temperature control and detection deliver reliable flash point results.
4. Digital display and clear result reporting for laboratory records.
5. Suitable for petroleum products, solvents, chemicals and quality control.
FAQ
Q1: What is the open and closed cup flash point tester mainly used for?
A: It is used to determine the flash point of petroleum products, solvents and chemicals, which indicates flammability and supports safety classification, quality control and regulatory compliance. Both open and closed cup methods can be performed for different material requirements.
Q2: What standards does the flash point tester comply with?
A: The instrument follows applicable ASTM, ISO and GB/T standards for open and closed cup flash point testing, including the Pensky-Martens and Cleveland methods. Test procedures should follow the applicable standard method. Compliance documentation can be provided on request.
Q3: What is the warranty period for the tester and key components?
A: The complete unit carries a 12-month warranty covering the instrument, controller and heating system. Sample cups, sensors and accessories are excluded. Damage from improper use or unauthorised repair is not covered.
Q4: Is the flash point tester difficult to operate?
A: Operation is straightforward: load the sample, select the test method and start the test. Basic training in flash point testing and sample handling is recommended. The manual explains setup and cleaning, and remote guidance is available.
Q5: What is the typical lead time for order delivery?
A: Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.
Q6: Does the flash point tester require calibration or verification?
A: The instrument should be verified periodically using reference liquids with known flash points, typically every 6 to 12 months. The unit is factory tested before delivery. Optional calibration service can be arranged.
Q7: Are consumables or spare parts universal?
A: Sample cups and standard spare parts are available through our channel. No proprietary consumables are required. Provide the model and serial number when ordering.
Q8: Can the flash point tester be customised?
A: Yes, options include different temperature ranges, test methods, data output, 220V or 110V supply and additional accessories. We confirm each option before order confirmation.
Q9: Is installation and commissioning included?
A: The unit is commissioned by following the manual, including electrical checks and a verification test. Remote guidance is available during commissioning. On-site installation can be arranged separately.
Q10: What samples should not be tested in this instrument?
A: Samples that decompose or react dangerously near their flash point, or materials not compatible with the test cup, should not be tested without appropriate precautions. Follow laboratory safety regulations.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.