Introduction

A petroleum semi automatic open cup flash point tester is an instrument used to measure the flash point of the petroleum products by the open cup method, with the semi-automated operation, and it is used in the petroleum, the fuel, the safety, and the quality control industries. The open cup method measures the flash point by the heating of the sample in an open cup at a controlled rate and the application of an ignition flame at the intervals, and it provides the flash point and the fire point, following the standard test methods, such as the ASTM and the ISO standards; the petroleum semi automatic open cup flash point tester consists of a test cup, a heating and a temperature control system, an ignition source, a semi-automated detection system, and the observation, and it provides the flash point with the semi-automated operation, in which the heating and the temperature measurement are automated and the detection is assisted; the petroleum semi automatic open cup flash point tester is used for the measurement of the flash point of the fuel oils, the lubricants, and the other petroleum products, for the safety, for the classification, for the quality control, and for many other applications, and it is an essential instrument for the petroleum testing. Petroleum semi automatic open cup flash point testers are used in the petroleum industry, in the fuel industry, in the safety, in the laboratories, and for many other applications. With their semi-automated operation, petroleum semi automatic open cup flash point testers are essential for the flammability assessment.

Semi-Automatic Open Cup Flash Point Tester T-S210OFP

Semi-Automatic Open Cup Flash Point Tester T-S210OFP


Semi-Automatic Open Cup Flash Point Tester determines flash point of a liquid sample efficiently. It is incorporated with advanced temperature control features. The Cleveland Open Cup (CO...

Standards

ASTM D93-Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester

Complies with the above standards, but is not limited to them.

Features

1. Semi-automatic open cup flash point tester for petroleum product fire hazard assessment.

2. Combines automated heating and temperature control with manual ignition source application.

3. Suitable for fuel oils, lubricating oils, bitumen and other high-flash petroleum products.

4. Includes test cup, thermometer, heating apparatus and safety features for reliable operation.

5. Cost-effective solution for laboratories requiring open cup flash point measurement.

FAQ

Q1: What testing scenarios is this instrument mainly applied to?

A: The semi-automatic open cup flash point tester is used in petroleum refineries, fuel quality laboratories, lubricant manufacturers and third-party testing organizations to measure the flash point and fire point of fuel oils, lubricating oils, bitumen and other petroleum products using the Cleveland open cup method. It supports product specification compliance, transportation classification, storage safety assessment and quality control. The semi-automatic design provides automated heating and temperature control while allowing manual ignition source application, offering a cost-effective alternative to fully automatic instruments. It is suitable for laboratories with moderate throughput that require accurate open cup flash point measurement for high-flash products where closed cup methods are not specified.

Q2: What standards does the instrument comply with?

A: The test method follows ASTM D92 for flash and fire points by Cleveland open cup, ISO 2592 for petroleum products flash and fire points, and the corresponding GB/T 3536 method. The instrument complies with relevant laboratory electrical and fire safety standards. Test cup dimensions and heating rate should follow the standard specification.

Q3: What is the warranty period for the whole machine and key components?

A: The heating apparatus and controller are covered by a 12-month warranty. The test cup, thermometer and ignition source are consumables or accessories excluded from warranty. Damage from improper heating rate, sample spillage or unauthorized repair is excluded.

Q4: Is this device difficult to operate? Is professional training required?

A: Operation requires trained laboratory personnel familiar with flash point testing and fire safety procedures. We provide an operation manual and remote guidance. Proper sample filling, heating rate monitoring and manual ignition source application are important for accurate results. Testing should be performed in a well-ventilated area away from drafts.

Q5: What is the typical lead-time for order delivery?

A: Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.

Q6: Is regular calibration required? What is the recommended calibration cycle?

A: Temperature calibration against a reference thermometer is recommended every 6-12 months. Heating rate verification should be performed periodically. Full method verification with a certified flash point reference material is recommended for accredited laboratories.

Q7: Are supporting consumables universal?

A: Test cups, thermometers and ignition gas are available from laboratory suppliers, though cup dimensions should match the standard method. Long-term consumable cost is low.

Q8: Can I customize parameters or supporting accessories?

A: Customization includes maximum temperature, automation level and ignition source type. Additional test cups and accessories can be ordered separately. Custom orders extend delivery lead-time.

Q9: Does the purchase include on-site installation and commissioning service?

A: Standard delivery includes the apparatus and accessories with an operation manual. Remote commissioning guidance is provided. On-site service is not included for standard orders.

Q10: What types of samples are compatible with this equipment?

A: The tester handles petroleum products with flash points above 79 degrees Celsius within the method range. Samples with lower flash points should use closed cup methods. Highly volatile or contaminated samples may produce inconsistent results. Users should follow proper safety procedures, including avoiding drafts and having fire safety equipment available. The open cup method requires careful attention to ignition source technique for reproducible results.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.