A fan filter unit provides clean airflow by combining fan circulation and HEPA filtration. It is widely used in cleanrooms and controlled environments. The system ensures particulate control. It solves airborne contamination risks. By providing laminar clean air supply, it supports sterile production environments.
Fan Filter Unit LFFU-T2015
Fan Filter Unit offers an average wind speed of 0.3 to 0.5 m/s for achieving laminar flow with minimal turbulence. The system has low operational noise, enabling ultra-quiet performance ...
Fan Filter Unit LFFU-T2014
Fan Filter Unit offers an efficiency of 99.99% at 0.3µm for ensuring high-performance air filtration in demanding cleanrooms and critical environments. It includes optional test ports o...
Fan Filter Unit LFFU-T2013
Fan Filter Unit offers an air volume of 1000 m³/h, delivering effective laminar airflow performance by incorporating high-efficiency components and smart airflow management. It allows u...
Fan Filter Unit LFFU-T2012
Fan Filter Unit offers an average wind speed of 0.3 to 0.5 m/s for achieving laminar flow with minimal turbulence. It features low operation noise, enabling ultra-quiet performance at re...
Fan Filter Unit LFFU-T2010
Fan Filter Unit features an air volume of 500 m³/h, delivering effective laminar airflow performance. It has compact and adjustable FFUs that reduce dependence on central systems, insta...
Fan Filter Unit LFFU-T2011
Fan Filter Unit features an efficiency of 99.99% at 0.3µm for ensuring high-performance air filtration in demanding cleanrooms and critical environments. The unit has an adjustable spee...
Standards
ISO 29463-1:2024-High efficiency filters and filter media for removing particles in air-Classification, performance, testing and marking
EN 1822-1:2019-High efficiency air filters (EPA, HEPA and ULPA)-Classification, performance testing, marking
Complies with the above standards, but is not limited to them.
Features
1. Clear construction shows the filtration progress.
2. Compact design fits analytical benches.
3. Interchangeable funnels suit different volumes.
4. Chemical-resistant materials withstand common solvents.
5. Easy disassembly supports cleaning and sterilisation.
FAQ
What is the Fan Filter Unit mainly used for?
The Fan Filter Unit is used to separate particles from liquids or gases, or to prepare samples on membranes under pressure or vacuum. It supports analytical, environmental, microbiological and quality-control laboratories.
Which standards and regulations apply to the Fan Filter Unit?
The apparatus is designed with reference to IEC 61010 electrical safety, applicable filtration methods and relevant GB/T standards. Membranes and procedures should follow the standard. Compliance documentation can be provided on request.
What warranty comes with the Fan Filter Unit?
The system is covered for 12 months after shipment, including the main mechanism and electrical controls. Replaceable consumables and routine service items are not part of the warranty. Faults caused by improper installation outside the manual or unauthorised modification are not covered.
How easy is the Fan Filter Unit to use?
The controls are designed for regular laboratory use, so most users become confident after a brief introduction. The manual walks through each step, and common settings can be saved for repeat work. Online or on-site training is available if the site requires it.
How long does delivery usually take?
Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.
How often should the Fan Filter Unit be calibrated?
The unit is calibrated and tested before delivery. For ongoing accuracy, verify it against traceable reference standards every 6 to 12 months, or according to the laboratory quality schedule. We can arrange calibration service and certificates where required.
Are consumables and spare parts easy to obtain?
Filters, seals, probes and similar items are standard and can be supplied through our channel. Customers may also source equivalent items that meet the specification. Provide the model and serial number to confirm compatibility before ordering.
Can it be adapted to our requirements?
The standard model can be configured with selected accessories and operating options to suit the task. Non-standard requests are assessed before quotation so the final build is clearly defined. We confirm details before production.
How is the Fan Filter Unit commissioned?
Benchtop and standard units typically require only placement and connection before use, while larger systems may need professional commissioning. We confirm the installation requirements at order stage. On-site service and training can be provided if needed.
What should be avoided when using the Fan Filter Unit?
Do not use damaged or wrong-pore membranes, exceed pressure or vacuum ratings or spill solvent. Follow sample handling and laboratory safety rules.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.