Introduction
An automatic closed flash point tester measures flammability of liquids under sealed conditions. It is widely used in petroleum and chemical safety testing. It solves manual testing variability and ensures accurate fire safety classification.
Standards
ISO 2719:2025-Determination of flash point-Pensky-Martens closed cup method
ASTM D93-25-Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester
ISO/TR 29662:2020-Petroleum products and other liquids-Guidance for flash point and combustibility testing
Complies with the above standards, but is not limited to them.
Features
1. Automatic tag closed flash point tester for determining the flash point of liquid materials.
2. Automated test procedure improves repeatability and reduces operator dependence.
3. Precise temperature control and detection deliver reliable flash point results.
4. Digital display and clear result reporting for laboratory records.
5. Suitable for paints, solvents, petroleum products and chemical liquids.
FAQ
Q1: What is the automatic tag closed flash point tester mainly used for?
A: It is used in paint, solvent, petroleum and chemical laboratories to determine the closed-cup flash point of liquids, which indicates flammability and supports safety classification, quality control and regulatory compliance for transport and storage.
Q2: What standards does the flash point tester comply with?
A: The instrument follows the Tag closed-cup flash point test method and relevant ISO and GB/T standards for flash point determination. Test procedures should follow the applicable standard method. Compliance documentation can be provided on request.
Q3: What is the warranty period for the tester and key components?
A: The complete unit carries a 12-month warranty covering the instrument, controller and heating system. Sample cups, sensors and accessories are excluded. Damage from improper use or unauthorised repair is not covered.
Q4: Is the flash point tester difficult to operate?
A: Operation is largely automatic: load the sample, start the test and read the result. Basic training in flash point testing and sample handling is recommended. The manual explains setup and cleaning, and remote guidance is available.
Q5: What is the typical lead time for order delivery?
A: Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.
Q6: Does the flash point tester require calibration or verification?
A: The instrument should be verified periodically using reference liquids with known flash points, typically every 6 to 12 months. The unit is factory tested before delivery. Optional calibration service can be arranged.
Q7: Are consumables or spare parts universal?
A: Sample cups and standard spare parts are available through our channel. No proprietary consumables are required. Provide the model and serial number when ordering.
Q8: Can the flash point tester be customised?
A: Yes, options include different temperature ranges, data output, 220V or 110V supply and additional test modes. We confirm each option before order confirmation.
Q9: Is installation and commissioning included?
A: The unit is commissioned by following the manual, including electrical checks and a verification test. Remote guidance is available during commissioning. On-site installation can be arranged separately.
Q10: What samples should not be tested in this instrument?
A: Samples that decompose or react dangerously near their flash point, or materials not compatible with the test cup, should not be tested without appropriate precautions. Follow laboratory safety regulations.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.