Introduction
A medical autoclave is specifically designed for healthcare environments to sterilize surgical instruments, dressings, and medical supplies. It complies with medical sterilization standards and ensures complete microbial inactivation using saturated steam under pressure. The equipment includes multiple safety protection systems and automatic control functions. It is widely used in hospital sterilization centers and plays a key role in maintaining sterile conditions in clinical applications.
Horizontal Autoclave T-HA-L2105
Horizontal Autoclave T-HA-L2104
Horizontal Autoclave T-HA-L2103
Horizontal Autoclave T-HA-L2102
Horizontal Autoclave T-HA-L2101
Horizontal Autoclave T-HA-L2100
Horizontal Autoclave T-HA-S2204
Horizontal Autoclave T-HA-S2701
Horizontal Autoclave T-HA-S2601
Horizontal Autoclave T-HA-S2501
Horizontal Autoclave T-HA-S2502
Horizontal Autoclave T-HA-S2500
Horizontal Autoclave T-HA-S2403
Horizontal Autoclave T-HA-S2402
Horizontal Autoclave T-HA-S2401
Horizontal Autoclave T-HA-S2400
Horizontal Autoclave T-HA-S2302
Horizontal Autoclave T-HA-S2301
Horizontal Autoclave T-HA-S2300
Horizontal Autoclave T-HA-S2201
Horizontal Autoclave T-HA-S2203
Horizontal Autoclave T-HA-S2202
Horizontal Autoclave T-HA-S2200
Horizontal Autoclave T-HA-S2103
Horizontal Autoclave T-HA-S2102
Horizontal Autoclave T-HA-S2101
Horizontal Autoclave T-HA-S2100
Horizontal Autoclave T-S215HCA
Horizontal Autoclave operates at a working temperature of 134℃, with an adjustable temperature range from 40℃ to 134℃. It has a 150L chamber, providing ample space for sterilizing larg...
Horizontal Autoclave T-S214HCA
Horizontal Autoclave has a capacity of 500 L with a maximum working temperature of 134 °C, ensuring versatile and efficient sterilization. It operates at a working pressure of 0.22 MPa,...
Horizontal Autoclave T-S213HCA
Horizontal Autoclave features a 400 L stainless steel chamber and operates at a working pressure of 0.22 MPa for safe and reliable sterilization. It supports a temperature range of 40 t...
Horizontal Autoclave T-S212HCA
Horizontal Autoclave features a capacity of 280 L with a temperature range of 40 to 134 °C, ensuring versatile and efficient sterilization. It operates at a working pressure of 0.22 MP...
Horizontal Autoclave T-S211HCA
Horizontal Autoclave comes with a 200 L stainless steel chamber, providing ample capacity for bulk sterilization. It operates within a temperature range of 40 to 134 °C with ≤ ±2 ...
Horizontal Autoclave T-S210HCA
Horizontal Autoclave has a capacity of 150 L with a temperature range of 40 to 134 °C, ensuring versatile and efficient sterilization. It operates at a working pressure of 0.22 MPa, wit...
Horizontal Autoclave CH2057
Horizontal Autoclave features maximum operating temperature 138℃. It features a high capacity 500L chamber and a horizontal cylindrical design for smooth loading and optimal performance....
Horizontal Autoclave CH2056
Horizontal Autoclave is tripled design with 6mm thick chamber and mineral wool insulation for uniform temperature. It supports fully automatic sterilization cycle with preheating, vacuum,...
Horizontal Autoclave CH2055
Horizontal Autoclave provides 500 L of chamber capacity for large-scale operations. It operates at an adjustable temperature range within 40° to 134°C. Built-in over-temperature and ove...
Horizontal Autoclave CH2054
Horizontal Autoclave offers 400 L of chamber capacity for larger loads of sterilization. Equipped with an automatic steam release and vacuum exhaust system. Designed with a vacuum jacket ...
Horizontal Autoclave CH2053
Horizontal Autoclave features 280 L of chamber capacity for maximum load and operates at an adjustable temperature range within 105°C to 134°C for optimum sterilization. It features a g...
Horizontal Autoclave CH2052
Horizontal Autoclave provides 200 L of chamber capacity for large sterilization needs. It offers multiple adjustable sterilization cycles for different materials. Integrated with a digita...
Horizontal Autoclave CH20520
Horizontal Autoclave offers 150 L of capacity to provide space for multiple loads. It operates at an adjustable temperature range within 40° to 134°C for optimal sterilization. Built wi...
Rectangular Horizontal Autoclave RH2054
Rectangular Horizontal Autoclave provides 280 L of chamber capacity for large load of sterilization. It operates at an adjustable temperature range within 115° to 134°C for various item...
Rectangular Horizontal Autoclave RH2053
Rectangular Horizontal Autoclave offers 200 L chamber to allow sterilization of a wide range of items. Built-in recirculating system to reduce the amount of water required during each ste...
Rectangular Horizontal Autoclave RH2052
Rectangular Horizontal Autoclave offers 100 L for a higher load capacity. It operates at an adjustable temperature range within 115° to 134°C to accommodate a variety of sterilization n...
Rectangular Horizontal Autoclave RH2051
Rectangular Horizontal Autoclave includes 150 L of chamber capacity. Ergonomically designed door with secure locking and easy handling. Equipped with a built-in recirculating system that ...
Standards
IEC 61010-2-040:2020-Particular requirements for sterilizers and washer-disinfectors used to treat medical materials
ISO 17665-1:2006-Sterilization of health-care products-Moist heat-Part 1: Requirements for the development, validation and routine control of a sterilization process for medical devices
Complies with the above standards, but is not limited to them.
Features
1. Vertical, horizontal and benchtop models suit various spaces.
2. Efficient vacuum pulses remove air from wrapped and hollow loads.
3. Printer or data-logger option provides cycle records.
4. Quiet operation and heat-insulated panels suit busy work areas.
5. Fast cycles and effective drying improve instrument turnaround.
FAQ
What is the Medical Autoclave mainly used for?
The Medical Autoclave is used to sterilise instruments, glassware, media and waste using pressurised saturated steam. It is essential in microbiology, clinical, dental, pharmaceutical and research laboratories and in central sterile supply.
Which standards and regulations apply to the Medical Autoclave?
The unit is designed with reference to applicable pressure-vessel safety rules, IEC 61010 electrical requirements and relevant GB/T standards for sterilizers. Sterilization cycles should follow applicable standards and validated procedures. Compliance documentation can be provided on request.
What does the warranty cover?
The complete unit carries a 12-month warranty from delivery, covering the main body, core components and controller against manufacturing defects. Consumables and wearing parts such as filters, seals and probes are not covered. Damage from misuse, improper power or unauthorised repair is excluded, and extended warranty can be quoted.
Will staff need special training?
Day-to-day use is simple, with clear prompts and pre-set functions reducing manual steps. New operators should review the manual and complete a short familiarisation. Our technical team offers remote support during the first runs.
How long does delivery usually take?
Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.
Is calibration included?
To protect result reliability, periodic verification should be performed, typically once or twice a year. The instrument arrives factory-calibrated, and self-check routines help spot drift. We offer traceable calibration service if the site needs it.
Are the consumables universal or proprietary?
No proprietary consumable contract is required; standard parts are available from us and common laboratory suppliers. Our service team can supply a recommended parts list for the model. Most routine spares are held for quick delivery.
Can it be adapted to our requirements?
The standard model can be configured with selected accessories and operating options to suit the task. Non-standard requests are assessed before quotation so the final build is clearly defined. We confirm details before production.
Do you provide on-site installation?
Most models can be commissioned by following the manual, including positioning, connections, checks and a first test run. Remote guidance is available during start-up. On-site installation, commissioning and training can be arranged separately where required.
What should be avoided when using the Medical Autoclave?
Do not sterilise sealed containers or incompatible materials, and never open the chamber while pressurised. Ensure air removal and drying for effective sterilization. Follow pressure-vessel safety rules.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.