Introduction

A double beam UV-visible spectrophotometer is an analytical instrument used to measure the absorption and the transmittance of the light by the samples over the ultraviolet and the visible wavelength regions, with the double beam optical design, and it is used in the chemistry, the biology, the clinical, the pharmaceutical, and the many other laboratories. The double beam UV-visible spectrophotometer measures the absorbance of the light by the sample, with the light beam split into the sample beam and the reference beam, and the ratio of the intensities measured, which compensates for the fluctuations of the light source and the drift, providing the stable and the accurate measurements; the double beam UV-visible spectrophotometer consists of a light source, a monochromator, a beam splitter, the sample and the reference compartments, a detector, and a control and a data analysis system, and it provides features such as the wavelength scanning, the kinetic measurements, and the standard curve analysis; the double beam UV-visible spectrophotometer is used for the quantitative and the qualitative analysis, for the measurement of the concentration of the samples, for the analysis of the nucleic acids and the proteins, for the quality control, for the research, and for many other applications, and it is an essential instrument for the UV-visible analysis. Double beam UV-visible spectrophotometers are used in the chemistry and the biology laboratories, in the clinical laboratories, in the pharmaceutical industry, in the food industry, and for many other applications. With their double beam design, double beam UV-visible spectrophotometers are essential for the accurate absorbance measurements.

Double Beam UV/Visible Spectrophotometer T-UD-S2113

Double Beam UV/Visible Spectrophotometer T-UD-S2113

Double Beam UV/Visible Spectrophotometer supports wavelength span from 190 to 1100 nm. Incorporates selectable bandwidths for enhanced analytical performance. Equipped with deuterium and t...
Double Beam UV/Visible Spectrophotometer T-UD-S2112

Double Beam UV/Visible Spectrophotometer T-UD-S2112

Double Beam UV/Visible Spectrophotometer offers extensive wavelength coverage ranging from 190 to 1100 nm. Designed with 1 nm spectral bandwidth for enhanced resolution. It ensures dependa...
Double Beam UV/Visible Spectrophotometer T-UD-S2111

Double Beam UV/Visible Spectrophotometer T-UD-S2111

Double Beam UV/Visible Spectrophotometer covers wide wavelength range from 190 to 1100 nm. Its double-beam configuration supports consistent light intensity across sample and reference pat...
Double Beam UV/Visible Spectrophotometer T-UD-S2110

Double Beam UV/Visible Spectrophotometer T-UD-S2110

Double Beam UV/Visible Spectrophotometer operates across range of 190 to 1100 nm. Built with advanced double-beam optical layout ensuring consistent spectral scanning. Equipped with auto w...
Double Beam UV/Visible Spectrophotometer T-UD-S2109

Double Beam UV/Visible Spectrophotometer T-UD-S2109

Double Beam UV/Visible Spectrophotometer features variable bandwidth options ranging from 0.1 to 5 nm. Incorporates highly stable double-beam optical configuration ensuring consistent base...
Double Beam UV/Visible Spectrophotometer T-UD-S2108

Double Beam UV/Visible Spectrophotometer T-UD-S2108

Double Beam UV/Visible Spectrophotometer offers narrow 1 nm spectral bandwidth for superior analytical resolution. Designed with wide wavelength range covering ultraviolet to visible light...
Double Beam UV/Visible Spectrophotometer T-UD-S2207

Double Beam UV/Visible Spectrophotometer T-UD-S2207

Double Beam UV/Visible Spectrophotometer operates within wavelength range of 190 to 1100 nm. Built with double-beam optical system, it ensures stable readings across extended measurements....
Double Beam UV/Visible Spectrophotometer T-UD-S2206

Double Beam UV/Visible Spectrophotometer T-UD-S2206

Double Beam UV/Visible Spectrophotometer is designed for precise measurement of light intensity across a wide wavelength range from 190 nm to 1100 nm. Integrated USB interface facilitates ...
Double Beam UV/Visible Spectrophotometer T-UD-S2205

Double Beam UV/Visible Spectrophotometer T-UD-S2205

Double Beam UV/Visible Spectrophotometer covers wavelength range from 190 to 1100 nm. Built with 2nm bandwidth, it offers fine spectral resolution. Equipped with socket-type deuterium and ...
Double Beam UV/Visible Spectrophotometer T-UD-S2204

Double Beam UV/Visible Spectrophotometer T-UD-S2204

Double Beam UV/Visible Spectrophotometer utilizes both tungsten and deuterium lamps as light sources providing stable output for accurate readings. With a wavelength range from 190 to 1100...
Double Beam UV/Visible Spectrophotometer T-UD-S2203

Double Beam UV/Visible Spectrophotometer T-UD-S2203

Double Beam UV/Visible Spectrophotometer is configured with a high-resolution 5-inch color display for user-friendly menu navigation. spectrophotometer is capable of measuring absorbance o...
Double Beam UV/Visible Spectrophotometer T-UD-S2202

Double Beam UV/Visible Spectrophotometer T-UD-S2202

Double Beam UV/Visible Spectrophotometer is capable of measuring the absorbance or transmittance of light over a broad wavelength range (190–1100 nm), guaranteeing safe analysis. spectrop...
Double Beam UV/Visible Spectrophotometer T-UD-S2201

Double Beam UV/Visible Spectrophotometer T-UD-S2201

Double Beam UV/Visible Spectrophotometer is designed with high-resolution touchscreen display that allow real time monintoring of measuring the absorbance or transmittance of light through...
Double Beam UV/Visible Spectrophotometer T-UD-S2200

Double Beam UV/Visible Spectrophotometer T-UD-S2200

Double Beam UV/Visible Spectrophotometer is a highly efficient spectrophotometer convenient for spectrophotometric analysis, measuring the absorbance or transmittance of light through a sa...
Double Beam UV/Visible Spectrophotometer T-UD-L2109

Double Beam UV/Visible Spectrophotometer T-UD-L2109

Double Beam UV/Visible Spectrophotometer offers wavelength spans from 190 nm to 1100 nm. It offers selectable bandwidths of 0.5 nm, 1 nm, 2 nm, 4 nm, and 5 nm for versatile measurement. It...
Double Beam UV/Visible Spectrophotometer T-UD-L2106

Double Beam UV/Visible Spectrophotometer T-UD-L2106

Double Beam UV/Visible Spectrophotometer offers 2nm spectral bandwidth. It features automatic wavelength setting for simplified calibration. Its low noise and minimal stray light enhance s...
Double Beam UV/Visible Spectrophotometer T-UD-L2105

Double Beam UV/Visible Spectrophotometer T-UD-L2105

Double Beam UV/Visible Spectrophotometer offers 2 nm spectral bandwidth. Its automatic wavelength setting simplifies operation by eliminating manual adjustments. It features low noise for ...
Double Beam UV/Visible Spectrophotometer T-UD-L2102

Double Beam UV/Visible Spectrophotometer T-UD-L2102

Double Beam UV/Visible Spectrophotometer operates between 190 nm to 1100 nm. Its automatic wavelength setting enables simplified calibration. It features low stray light, ensuring clear an...
Double Beam UV/Visible Spectrophotometer T-UD-L2101

Double Beam UV/Visible Spectrophotometer T-UD-L2101

Double Beam UV/Visible Spectrophotometer works between 190 to 1100 nm. It features automatic wavelength setting for simplified calibration. Its multiple photometric modes offer versatile m...
Double Beam UV/Visible Spectrophotometer T-UD-S2107

Double Beam UV/Visible Spectrophotometer T-UD-S2107

Double Beam UV/Visible Spectrophotometer is designed with fixed spectral bandwidth of 2nm for better resolution. Offers broad wavelength range from 190 to 1100nm to cover both UV and visib...
Double Beam UV/Visible Spectrophotometer T-UD-S2106

Double Beam UV/Visible Spectrophotometer T-UD-S2106

Double Beam UV/Visible Spectrophotometer offers wavelength range of 190-1100 nm. It delivers high-resolution spectral analysis with dual beam technology. Equipped with user-friendly interf...
Double Beam UV/Visible Spectrophotometer T-UD-S2105

Double Beam UV/Visible Spectrophotometer T-UD-S2105

Double Beam UV/Visible Spectrophotometer covers range of 190 to 1100 nm. It offers adjustable spectral bandwidths suitable for different sample types and measurement needs. Ensures consist...
Double Beam UV/Visible Spectrophotometer T-UD-S2104

Double Beam UV/Visible Spectrophotometer T-UD-S2104

Double Beam UV/Visible Spectrophotometer delivers spectral coverage between 190 and 1100 nm. Built with 1nm spectral bandwidth and double-beam optical system for reliable performance. Main...
Double Beam UV/Visible Spectrophotometer T-UD-S2103

Double Beam UV/Visible Spectrophotometer T-UD-S2103

Double Beam UV/Visible Spectrophotometer offers wavelength range from 190 to 1100 nm. Incorporates 1200 lines/mm grating within high-performance double-beam optical layout. Built with adva...
Double Beam UV/Visible Spectrophotometer T-UD-S2102

Double Beam UV/Visible Spectrophotometer T-UD-S2102

Double Beam UV/Visible Spectrophotometer covers wavelength range from 190 to 1100 nm. Its optical design employs dual-beam system with high-resolution grating. Built to provide comprehensi...
Double Beam UV/Visible Spectrophotometer T-UD-S2100

Double Beam UV/Visible Spectrophotometer T-UD-S2100

Double Beam UV/Visible Spectrophotometer features wavelength range of 190 to 1100nm for wide-spectrum optical analysis. Incorporates double-beam optical system, enhancing stability by mini...
Double Beam UV/Visible Spectrophotometer T-UD-S2101

Double Beam UV/Visible Spectrophotometer T-UD-S2101

Double Beam UV/Visible Spectrophotometer offers wavelength range of 190 to 1100 nm. Designed with automatic wavelength setting to streamline transitions between modes. Ensures reliable sta...

Standards

GB/T 26813-2010-Double-beam ultraviolet-visible spectrophotometers

European Pharmacopoeia 2.2.25-Spectrophotometry, ultraviolet and visible

ASTM E275-08(2022)-Standard Practice for Describing and Measuring Performance of Ultraviolet, Visible, and Near-Infrared Spectrophotometers

Complies with the above standards, but is not limited to them.

Features

1. Double-beam UV-visible spectrophotometer for high-accuracy absorbance measurement.

2. Dual-beam optical system automatically compensates for light source drift.

3. Wide wavelength range with high resolution for spectral scanning and analysis.

4. Suitable for pharmaceutical, chemical, environmental and research laboratories.

5. Software supports scanning, quantitation, kinetics and regulatory compliance features.

FAQ

Q1: What testing scenarios is this instrument mainly applied to?

A: The double-beam UV-visible spectrophotometer is used in pharmaceutical, chemical, environmental, food and research laboratories for high-accuracy qualitative and quantitative analysis by absorbance measurement in the ultraviolet and visible ranges. It supports drug content and impurity analysis, compound identification by spectral scanning, enzyme kinetics, nucleic acid and protein quantitation, water quality testing and method development. The double-beam design provides superior stability by continuously comparing sample and reference beams, automatically compensating for light source drift during long scans and kinetic measurements. It is the standard for regulated pharmaceutical quality control and research requiring the highest accuracy and reproducibility, particularly for spectral scanning, time-based kinetics and low-absorbance measurements where source instability would affect result quality.

Q2: What standards does the instrument comply with?

A: The instrument supports analytical methods referenced in USP, EP and ChP monographs, ASTM E169 for UV-Vis quantitative analysis, and relevant GB/T standards for spectrophotometry. The hardware complies with IEC 61010 laboratory safety standards. Electronic records may be configured for 21 CFR Part 11 compliance. Wavelength and absorbance accuracy should be verified with certified reference materials.

Q3: What is the warranty period for the whole machine and key components?

A: The whole spectrophotometer is covered by a 12-month warranty. The optical system, detector, light source and controller are covered, while lamps, cuvettes and calibration standards are consumables excluded from warranty. Extended warranty and service contracts are available.

Q4: Is this device difficult to operate? Is professional training required?

A: Operation requires trained analysts familiar with spectrophotometric principles and method execution. We provide structured training, operation manuals and application support. Routine measurement and scanning can be performed by trained operators with software guidance and standard operating procedures.

Q5: What is the typical lead-time for order delivery?

A: Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.

Q6: Is regular calibration required? What is the recommended calibration cycle?

A: Wavelength and absorbance calibration with certified reference materials is recommended every 6-12 months for accredited laboratories. Routine verification before each analytical batch is recommended for regulated work. Lamp replacement and optical alignment follow the manufacturer schedule.

Q7: Are supporting consumables universal?

A: Lamps, cuvettes and calibration standards are available from multiple qualified suppliers, though original lamps and optics are recommended for optimal performance. Long-term consumable cost is moderate.

Q8: Can I customize parameters or supporting accessories?

A: Customization includes wavelength range, resolution, detector type, sample compartment accessories and software modules. Additional accessories can be ordered separately. Custom orders extend delivery lead-time.

Q9: Does the purchase include on-site installation and commissioning service?

A: Standard delivery includes the spectrophotometer and accessories with an operation manual. Remote commissioning guidance is provided. On-site installation and training are not included for standard orders but can be arranged for laboratory setup projects.

Q10: What types of samples are compatible with this equipment?

A: The instrument analyzes liquid samples within the wavelength and absorbance range. Samples must be clear and homogeneous; turbid samples cause scattering errors. Highly corrosive samples require compatible cuvette material. Very high absorbance samples should be diluted to the linear range. The double-beam design requires proper reference cell placement and baseline correction for optimal performance. Users should allow lamp warm-up and perform system suitability verification before critical measurements.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.

Inquiry