Introduction
Automatic Closed Cup Flash Point Tester determines flash points of liquids with fully automated operation. They function with sealed test chambers, ignition systems, and programmable heating cycles. These units feature digital controls, safety mechanisms, and fast response sensors for efficient analysis. Their compact design and intuitive interface ensure smooth handling and minimal supervision. Flash Point Tester supports standard test methods and delivers consistent performance for routine analysis.
Automatic Closed Cup Flash Point Tester T-CCT-S2102
Automatic Closed Cup Flash Point Tester T-CCT-S2101
Automatic Closed Cup Flash Point Tester T-CCT-S2100
Standards
ISO 2719:2025-Determination of flash point-Pensky-Martens closed cup method
ASTM D93-25-Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester
ISO/TR 29662:2020-Petroleum products and other liquids-Guidance for flash point and combustibility testing
Complies with the above standards, but is not limited to them.
Features
1. Data storage and export support batch records.
2. Automatic detection and ignition reduce operator dependence.
3. Sample cups and accessories follow standard dimensions.
4. Precise heating and detection give repeatable flash-point results.
5. Cooling and ventilation functions speed turn-around.
FAQ
What are the main applications of the Automatic Closed Cup Flash Point Tester?
The Automatic Closed Cup Flash Point Tester is used to determine the lowest temperature at which a sample's vapours ignite briefly. It indicates flammability and supports safety classification, fuel handling and quality control for petroleum products, solvents and chemicals.
Which standards and regulations apply to the Automatic Closed Cup Flash Point Tester?
The tester is designed with reference to applicable ASTM, ISO and GB/T flash-point methods, such as Pensky-Martens or Cleveland open cup, and IEC 61010 electrical safety. Procedures must follow the relevant method. Compliance documentation can be provided on request.
How long is the warranty period?
We provide a 12-month limited warranty on the instrument and its key working parts. Consumables, accessories and parts subject to normal wear are excluded, as is damage caused by incorrect operation or maintenance. An extended service plan is available on request.
Will staff need special training?
No advanced specialist skills are needed for standard operation, though correct sample handling and safety practice should be followed. We supply a detailed manual and start-up support. For multi-user or regulated sites, a short staff training session can be arranged.
How long does delivery usually take?
Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.
Is calibration included?
Regular calibration keeps measurements within the stated accuracy; an annual check is typical, with shorter intervals for heavy or regulated use. Reference standards and procedures are described in the manual. We can quote calibration with certificates.
Are the consumables universal or proprietary?
No proprietary consumable contract is required; standard parts are available from us and common laboratory suppliers. Our service team can supply a recommended parts list for the model. Most routine spares are held for quick delivery.
Can the Automatic Closed Cup Flash Point Tester be customised?
A range of options is available to match the application, such as alternative settings, fittings, data outputs or power supply. We confirm each option and its effect on price and schedule up front. Larger custom builds can be discussed.
How is the Automatic Closed Cup Flash Point Tester commissioned?
Benchtop and standard units typically require only placement and connection before use, while larger systems may need professional commissioning. We confirm the installation requirements at order stage. On-site service and training can be provided if needed.
What should be avoided when using the Automatic Closed Cup Flash Point Tester?
Do not test samples that react dangerously near ignition, leave the test unattended or use the wrong cup method. Work away from ignition sources and ventilate. Follow laboratory safety rules.