Introduction

Vibration Magnetometer provides magnetic property evaluation across -193°C (degrees Celsius) to 777°C (degrees Celsius) temperature range. They maintain controlled conditions with a 20°C (degrees Celsius)/min adjustable rate and vacuum-based insulation. These ensure minimal thermal loss while preserving the physical structure of various substances. Their non-destructive testing capability enables advanced research in material science. Vibration Magnetometer enhances studies in nano magnetism, spintronics, bio-magnetic interaction, quantum phenomena, and sample characterization.

Vibration Magnetometer T-VMM-S2100

Vibration Magnetometer T-VMM-S2100

Vibration Magnetometer offers 20°C/min variable temperature range with sustaining 15 minutes in low and 35 minutes in high. It incorporates vacuum-based thermal insulation, ensuring minim...

Standards

IEC 61786-1:2013-Measurement of DC magnetic, AC magnetic and AC electric fields from 1 Hz to 100 kHz with regard to exposure of human beings-Requirements for measuring instruments

Complies with the above standards, but is not limited to them.

Features

1. Multiple ranges cover weak to strong fields.

2. Calibration certificates are available.

3. Portable, battery-powered design supports field use.

4. Precise Hall or sensor probe gives stable field readings.

5. Zero adjustment removes background offset.

FAQ

What are the main applications of the Vibration Magnetometer?

The Vibration Magnetometer is used to measure magnetic field strength, flux or related magnetic properties. It supports materials testing, motor and magnet inspection, laboratories, manufacturing and field surveys.

Which standards and regulations apply to the Vibration Magnetometer?

The instrument is designed with reference to applicable magnetic-measurement standards, IEC 61010 electrical safety and relevant GB/T methods. Calibration should use traceable references. Compliance documentation can be provided on request.

How long is the warranty period?

The system is covered for 12 months after shipment, including the main mechanism and electrical controls. Replaceable consumables and routine service items are not part of the warranty. Faults caused by improper installation outside the manual or unauthorised modification are not covered.

Is the Vibration Magnetometer difficult to operate?

No advanced specialist skills are needed for standard operation, though correct sample handling and safety practice should be followed. We supply a detailed manual and start-up support. For multi-user or regulated sites, a short staff training session can be arranged.

What is the typical lead time for order delivery?

Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.

Does the Vibration Magnetometer need calibration or verification?

Regular calibration keeps measurements within the stated accuracy; an annual check is typical, with shorter intervals for heavy or regulated use. Reference standards and procedures are described in the manual. We can quote calibration with certificates.

Where do we get replacement parts?

No proprietary consumable contract is required; standard parts are available from us and common laboratory suppliers. Our service team can supply a recommended parts list for the model. Most routine spares are held for quick delivery.

Can it be adapted to our requirements?

The standard model can be configured with selected accessories and operating options to suit the task. Non-standard requests are assessed before quotation so the final build is clearly defined. We confirm details before production.

Is installation and commissioning included?

The unit is delivered ready for set-up, with clear commissioning steps in the manual. We provide remote technical support during installation. For larger or regulated systems, a factory-trained engineer can attend on site on request.

What should be avoided when using the Vibration Magnetometer?

Do not use probes outside the axis or range, ignore zero offsets or measure near interfering fields. Zero and orient the probe correctly. Follow the operating instructions.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.

Inquiry