Introduction

A side air out cold room unit is a refrigeration unit designed for the cold rooms, with the air outlet at the side of the unit, and it provides the cooling and the temperature control for the storage of the products at the low temperatures, and it is used in the food, the beverage, the pharmaceutical, the logistics, and the many other industries. The side air out cold room unit consists of the compressor, the condenser, the evaporator, the expansion valve, the fans, which discharge the cold air from the side, the control system, and the housing, and it is installed inside or on the cold room, with the side air outlet directing the cold air, and it provides the cooling and the temperature control, with features such as the digital temperature control, the defrost, and the alarms; the side air out cold room unit is used for the cooling of the cold rooms for the storage of the food, the beverages, the flowers, the pharmaceuticals, and the other products, for the refrigerated storage, for the temperature control, and for many other applications, and it is available in various capacities, for the different sizes of the cold rooms; the side air out cold room unit is an essential equipment for the cold room refrigeration. Side air out cold room units are used in the food and the beverage industry, in the pharmaceutical industry, in the logistics, in the supermarkets, and for many other applications. With their side air outlet, side air out cold room units are essential for the cold storage.

Side Air-out Cold Room Unit T-S221SAO

Side Air-out Cold Room Unit T-S221SAO


Side Air-out Cold Room Unit is outfitted with an intelligent defrosting control mode. It has a storage temperature in the range from -10 °C to 10 °C. It features a R22 refrigerant. It...
Side Air-out Cold Room Unit T-S222SAO

Side Air-out Cold Room Unit T-S222SAO


Side Air-out Cold Room Unit is outfitted with an intelligent defrosting control mode. It has a storage temperature in the range from -10 °C to 10 °C. It features a R22 refrigerant. It...
Side Air-out Cold Room Unit T-S223SAO

Side Air-out Cold Room Unit T-S223SAO


Side Air-out Cold Room Unit is outfitted with an intelligent defrosting control mode. It has a storage temperature in the range from -10 °C to 10 °C. It features a R22 refrigerant. It...
Side Air-out Cold Room Unit T-S218SAO

Side Air-out Cold Room Unit T-S218SAO


Side Air-out Cold Room Unit is outfitted with an intelligent defrosting control mode. It has a storage temperature in the range from -10 °C to 10 °C. It features a R22 refrigerant. It...
Side Air-out Cold Room Unit T-S219SAO

Side Air-out Cold Room Unit T-S219SAO


Side Air-out Cold Room Unit is outfitted with an intelligent defrosting control mode. It has a storage temperature in the range from -10 °C to 10 °C. It features a R22 refrigerant. It...
Side Air-out Cold Room Unit T-S220SAO

Side Air-out Cold Room Unit T-S220SAO


Side Air-out Cold Room Unit is outfitted with an intelligent defrosting control mode. It has a storage temperature in the range from -10 °C to 10 °C. It features a R22 refrigerant. It...
Side Air-out Cold Room Unit T-S217SAO

Side Air-out Cold Room Unit T-S217SAO


Side Air-out Cold Room Unit is outfitted with an intelligent defrosting control mode. It has a storage temperature in the range from -10 °C to 10 °C. It features a R22 refrigerant. It...
Side Air-out Cold Room Unit T-S213SAO

Side Air-out Cold Room Unit T-S213SAO


Side Air-out Cold Room Unit is outfitted with an intelligent defrosting control mode. It has a storage temperature in the range from -20 °C to 10 °C. It features a R404A refrigerant. ...
Side Air-out Cold Room Unit T-S214SAO

Side Air-out Cold Room Unit T-S214SAO


Side Air-out Cold Room Unit is outfitted with an intelligent defrosting control mode. It has a storage temperature in the range from -20 °C to 10 °C. It features a R404A refrigerant. ...
Side Air-out Cold Room Unit T-S215SAO

Side Air-out Cold Room Unit T-S215SAO


Side Air-out Cold Room Unit is outfitted with an intelligent defrosting control mode. It has a storage temperature in the range from -20 °C to 10 °C. It features a R404A refrigerant. ...
Side Air-out Cold Room Unit T-S216SAO

Side Air-out Cold Room Unit T-S216SAO


Side Air-out Cold Room Unit is outfitted with an intelligent defrosting control mode. It has a storage temperature in the range from -20 °C to 10 °C. It features a R404A refrigerant. ...
Side Air-out Cold Room Unit T-S210SAO

Side Air-out Cold Room Unit T-S210SAO


Side Air-out Cold Room Unit is outfitted with an intelligent defrosting control mode. It has a storage temperature in the range from -20 °C to 10 °C. It features a R404A refrigerant. ...
Side Air-out Cold Room Unit T-S211SAO

Side Air-out Cold Room Unit T-S211SAO


Side Air-out Cold Room Unit is outfitted with an intelligent defrosting control mode. It has a storage temperature in the range from -20 °C to 10 °C. It features a R404A refrigerant. ...
Side Air-out Cold Room Unit T-S212SAO

Side Air-out Cold Room Unit T-S212SAO


Side Air-out Cold Room Unit is outfitted with an intelligent defrosting control mode. It has a storage temperature in the range from -20 °C to 10 °C. It features a R404A refrigerant. ...

Standards

EN 14511-Air conditioners, liquid chilling packages and heat pumps with electrically driven compressors

Complies with the above standards, but is not limited to them.

Features

1. Monoblock refrigeration unit with side air discharge for cold room temperature control.

2. Integrated compressor, evaporator and condenser in a single housing for simplified wall installation.

3. Digital controller with temperature display, automatic defrost and high-low temperature alarm.

4. Suitable for medium and low temperature cold rooms in food service, retail and laboratory storage.

5. Side air discharge directs condenser heat horizontally for efficient heat rejection in confined spaces.

FAQ

Q1: What testing scenarios is this instrument mainly applied to?

A: The side air out cold room unit is used to maintain controlled temperature in cold storage rooms for food products, beverages, pharmaceuticals and laboratory reagents. It is commonly installed in restaurants, supermarkets, convenience stores and small warehouses where a self-contained refrigeration solution with side heat discharge is preferred to avoid heat recirculation against walls and maintain consistent room temperature for stored product quality and safety.

Q2: What standards does the instrument comply with?

A: The unit is designed with reference to IEC 60335 for electrical appliance safety, ISO 5151 for non-ducted air conditioner performance testing, and relevant GB standards for refrigeration equipment. Refrigerant selection follows current environmental regulations for the target market.

Q3: What is the warranty period for the whole machine and key components?

A: The whole unit is covered by a 12-month warranty. The compressor typically carries an extended warranty as specified in the product documentation. The control board, fan and sensors are covered, while filters and gaskets are consumables excluded from warranty.

Q4: Is this device difficult to operate? Is professional training required?

A: Operation is simple through the digital controller once installed. Professional installation by a qualified refrigeration technician is required for correct mounting, drainage and electrical connection. Routine temperature setting and alarm acknowledgment can be performed by facility staff.

Q5: What is the typical lead-time for order delivery?

A: Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.

Q6: Is regular calibration required? What is the recommended calibration cycle?

A: Temperature verification against a calibrated reference thermometer is recommended every 6-12 months, especially for pharmaceutical storage. Routine filter cleaning and condenser inspection should be performed quarterly to maintain cooling efficiency.

Q7: Are supporting consumables universal?

A: Air filters and door gaskets are available from the supplier or qualified aftermarket vendors. Refrigerant recharge should be performed by certified technicians. Long-term maintenance cost is moderate.

Q8: Can I customize parameters or supporting accessories?

A: Customization includes temperature range, cooling capacity, voltage and defrost configuration. Users should provide cold room dimensions and insulation specification for proper sizing. Custom orders extend delivery lead-time.

Q9: Does the purchase include on-site installation and commissioning service?

A: Standard delivery includes the unit and installation manual. On-site installation by a certified technician is recommended but not included. Installation service can be arranged for local projects at additional cost.

Q10: What types of samples are compatible with this equipment?

A: The unit maintains temperature for stored products within its rated range. It is not suitable for storing explosive, flammable or highly corrosive materials unless specifically rated. Users should verify temperature uniformity for regulated storage applications.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.

Inquiry