Introduction
Zeta Potential Analyzers offer accurate particle analysis and are capable of measuring a wide range of particle sizes. They utilize laser doppler electrophoresis technology for accurate analysis of particle stability. analyzers include automatic temperature control for consistent operation and a solid laser light source for reliable performance. They feature high-speed digital correlators for improved dynamic range and dry gas purge technology to prevent condensation. zeta potential analyzers deliver precise and reliable results in pharmaceuticals, nanotechnology, and materials research.
Surface Zeta Potential Analyzer T-S210ZPA
Surface Zeta Potential Analyzer can measure particles from 0.3 nm to 15 µm at angles of 90° and 12°. It operates across a temperature range of -15 °C to 120 °C, accommodating various...
Standards
ISO 13320:2020-Particle size analysis-Laser diffraction methods
Complies with the above standards, but is not limited to them.
Features
1. Compact dimensions and light weight ease bench placement.
2. Easy cleaning and maintenance extend service life.
3. Remote diagnostics support faster servicing and less downtime.
4. Clear labelling and colour-coded controls reduce operator error.
5. Rugged, field-tested construction holds up under daily laboratory use.
FAQ
What is the Zeta Potential Analyzer mainly used for?
The Zeta Potential Analyzer is used for a defined laboratory measurement, preparation or processing task. It supports analytical, quality-control, research, clinical or industrial work where consistent, repeatable results are required.
Which standards and regulations apply to the Zeta Potential Analyzer?
The instrument is designed with reference to IEC 61010 electrical safety, the applicable international standard for the measurement or process and relevant GB/T standards. Procedures should follow the relevant method. Compliance documentation can be provided on request.
How long is the warranty period?
A 12-month warranty applies to the complete equipment against defects in materials and workmanship. It excludes consumables, wearing components and accidental or misuse damage. Our service team handles claims against the serial number, and longer cover can be arranged.
How easy is the Zeta Potential Analyzer to use?
Day-to-day use is simple, with clear prompts and pre-set functions reducing manual steps. New operators should review the manual and complete a short familiarisation. Our technical team offers remote support during the first runs.
What is the typical lead time for order delivery?
Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.
Does the Zeta Potential Analyzer need calibration or verification?
Factory calibration is included, and routine verification is recommended every 6 to 12 months using suitable reference materials. Regulated sites may require more frequent checks and documented records. Calibration support and certificates can be provided on request.
Are consumables and spare parts easy to obtain?
Filters, seals, probes and similar items are standard and can be supplied through our channel. Customers may also source equivalent items that meet the specification. Provide the model and serial number to confirm compatibility before ordering.
Can it be adapted to our requirements?
Customisation is supported for many installations, including tailored parameters, connections and accessories. Our team reviews the requirement and confirms feasibility and lead time in advance. We avoid committing to options that cannot be delivered reliably.
Do you provide on-site installation?
Standard installation is straightforward and supported by the manual and start-up documentation. Our technical team can guide staff remotely through checks and validation. On-site commissioning is available as a quoted service.
What should be avoided when using the Zeta Potential Analyzer?
Do not use the instrument outside its rated range or intended samples, skip calibration or ignore safety and maintenance instructions. Follow the operating manual and laboratory safety rules.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.