Thermal Cyclers enable precise and efficient DNA amplification through automated Polymerase Chain Reaction (PCR) cycles for molecular biology applications. They rapidly alternate between denaturation, annealing, and extension temperature steps to exponentially amplify target DNA sequences. They are equipped with accurate temperature control, uniform heating blocks, and user-friendly interfaces to ensure reliable and reproducible results. thermal cyclers support various sample formats, making them ideal for genetic research, diagnostics, biotechnology, and clinical laboratories.

Dual Block Thermal Cycler T-MB-E101

Dual Block Thermal Cycler T-MB-E101

Dual Block Thermal Cycler utilizes 8 Peltier heating units to heat up the sample with 4 variations in temperature. It has preprogrammed 11 PCR protocols saved in internal flash memory. The...
Automatic Gradient thermal cycler T-S2G-D601

Automatic Gradient thermal cycler T-S2G-D601

Automatic Gradient thermal cycler has a sophisticated operating computer controlled software to guide the protocols for PCR analysis for once and it can operate the functions offline. The ...
Advanced Gradient Thermal Cycler T-S2G-C501

Advanced Gradient Thermal Cycler T-S2G-C501

Advanced Gradient Thermal Cycler is designed with 64×0.2 ml and 32×0.2 ml capacity and maximum heating rate of 8°C/s. It offers an Android operating system and 11 pre-installed program ...
Advanced Gradient Thermal Cycler T-S2G-C402

Advanced Gradient Thermal Cycler T-S2G-C402

Advanced Gradient Thermal Cycler operates with 64×0.2 ml and 32×0.2ml aluminum plates using anodizing technology. It features an automatic tightening and closing hot lid. Integrated andr...
Advanced Gradient Thermal Cycler T-S2G-C401

Advanced Gradient Thermal Cycler T-S2G-C401

Advanced Gradient Thermal Cycler is programmed with an Android operating system and 11 pre-installed standard program patterns. Integrated with Peltier heating units, it has an automatic t...
Advanced Gradient Thermal Cycler T-S2G-C202

Advanced Gradient Thermal Cycler T-S2G-C202

Advanced Gradient Thermal Cycler offer 96×0.2 ml capacity with 11 pre-installed programs. It features Corrosion-resistant aluminum built and Android OS. Equipped with Automatic Tightening...
Advanced Gradient Thermal Cycler T-S2G-C201

Advanced Gradient Thermal Cycler T-S2G-C201

Advanced Gradient Thermal Cycler is designed to supports PCR runs with 6×16×0.2 ml capacity and maximum heating rate of 5°C/s. It features an android system with 11 pre-installed progra...
Advanced Gradient Thermal Cycler T-S2G-C301

Advanced Gradient Thermal Cycler T-S2G-C301

Advanced Gradient Thermal Cycler is designed with an Android operating system. Incorporated anodizing technology supports PCR runs on 384-well aluminum plates. Equipped with Peltier heatin...
Advanced Thermal Cycler (Gradient) T-S2T-L2201

Advanced Thermal Cycler (Gradient) T-S2T-L2201

Advanced Thermal Cycler (Gradient) B201 features wide temperature range from 0°C to 100°C. It features dual block configuration with 96 wells for 0.2 mL tubes and 77 wells for 0.5 mL tub...
Advanced Thermal Cycler (Gradient) T-S2T-L2200

Advanced Thermal Cycler (Gradient) T-S2T-L2200

Advanced Thermal Cycler (Gradient) B200 features wide temperature range from 0°C to 100°C. It features dual block configuration with 48 wells for 0.2 mL tubes and 48 wells for 0.5 mL tub...
Advanced Thermal Cycler (Gradient) T-S2T-L2101

Advanced Thermal Cycler (Gradient) T-S2T-L2101

Advanced Thermal Cycler (Gradient) wide temperature range from 0°C to 99°C. It supports dual block configuration with 96 wells for 0.2 mL tubes and 77 wells for 0.5 mL tubes. Equipped wi...
Advanced Thermal Cycler (Gradient) T-S2T-L2100

Advanced Thermal Cycler (Gradient) T-S2T-L2100

Advanced Thermal Cycler (Gradient) wide temperature range from 0°C to 99°C. It supports dual block configuration with 48 wells for 0.2 ml tubes and 48 wells for 0.5 ml tubes. Equipped wi...
Advanced Thermal Cycler (Basic) T-S2T-S2201

Advanced Thermal Cycler (Basic) T-S2T-S2201

Advanced Thermal Cycler (Basic) features wide temperature range from 0°C to 100°C. It supports dual block configuration with 96 wells for 0.2 mL tubes and 77 wells for 0.5 mL tubes. Intu...
Advanced Thermal Cycler (Basic) T-S2T-S2101

Advanced Thermal Cycler (Basic) T-S2T-S2101

Advanced Thermal Cycler (Basic) features wide temperature range from 0°C to 99°C. It supports dual block configuration with 96 wells for 0.2 mL tubes and 77 wells for 0.5 mL tubes. Equip...
Advanced Thermal Cycler (Basic) T-S2T-S2100

Advanced Thermal Cycler (Basic) T-S2T-S2100

Advanced Thermal Cycler (Basic) features wide temperature range from 0°C to 99°C. It supports dual block configuration with 48 wells for 0.2 mL tubes and 48 wells for 0.5 mL tubes. Intui...
Thermal Cycler (basic) T-S210STR

Thermal Cycler (basic) T-S210STR


Thermal Cycler (basic) consist of 7 inch LCD 800×480 and the sample holding capacity of the device is 96×0.2 mL PCR tube, 8×12 PCR plate or 96 well plate all together. It has independe...

Standards

ISO 20836:2021-Microbiology of the food chain-PCR for the detection of microorganisms-Thermal performance testing of thermal cyclers

Complies with the above standards, but is not limited to them.

Features

1. Data export and analysis support research records.

2. Programmable protocols store cycling or imaging steps.

3. Fast block ramps shorten overall protocol time.

4. Compact bench design fits molecular laboratories.

5. Hot-lid function prevents condensation on samples.

FAQ

What is the Thermal Cycler mainly used for?

The Thermal Cycler is used in molecular and cell biology for amplification, separation, imaging or sample preparation. It supports PCR, electrophoresis, nucleic-acid work and related research and diagnostic laboratories.

What standards does the Thermal Cycler comply with?

The instrument is designed with reference to IEC 61010 electrical safety, applicable molecular-biology methods and relevant GB/T standards. Programs and reagents should follow validated protocols. Compliance documentation can be provided on request.

How long is the warranty period?

We provide a 12-month limited warranty on the instrument and its key working parts. Consumables, accessories and parts subject to normal wear are excluded, as is damage caused by incorrect operation or maintenance. An extended service plan is available on request.

Will staff need special training?

No advanced specialist skills are needed for standard operation, though correct sample handling and safety practice should be followed. We supply a detailed manual and start-up support. For multi-user or regulated sites, a short staff training session can be arranged.

How long does delivery usually take?

Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.

Does the Thermal Cycler need calibration or verification?

The unit is calibrated and tested before delivery. For ongoing accuracy, verify it against traceable reference standards every 6 to 12 months, or according to the laboratory quality schedule. We can arrange calibration service and certificates where required.

Are the consumables universal or proprietary?

The instrument uses standard, widely available consumables rather than special locked items. Replacement parts, accessories and consumables can be ordered from us against the model number. We keep common service parts in stock for prompt supply.

Can the Thermal Cycler be customised?

Customisation is supported for many installations, including tailored parameters, connections and accessories. Our team reviews the requirement and confirms feasibility and lead time in advance. We avoid committing to options that cannot be delivered reliably.

How is the Thermal Cycler commissioned?

Benchtop and standard units typically require only placement and connection before use, while larger systems may need professional commissioning. We confirm the installation requirements at order stage. On-site service and training can be provided if needed.

What should be avoided when using the Thermal Cycler?

Do not use contaminated samples or reagents, skip controls or block thermal or optical paths. Prevent cross-contamination and maintain calibration. Follow laboratory safety rules.