Introduction
Autoclavable glass fermenter is a specialized vessel designed for the cultivation and fermentation of microorganisms, cells, or proteins in a laboratory or industrial setting. These fermenters are made from borosilicate glass, known for its resistance to high temperatures and pressure, and can withstand autoclaving for sterilization purposes. They often feature airtight seals, specialized ports for adding and sampling materials, and integrated agitators to provide optimal conditions for microbial growth and fermentation processes.
Autoclavable glass fermenter T-S224GFS
Autoclavable glass fermenter is a mechanically driven stirred-tank bench top fermenting unit. Culture tank design aids interchangeability, reducing downtime during off-site sterilisation....
Autoclavable glass fermenter T-S223GFS
Autoclavable glass fermenter is a mechanically driven stirred-tank bench top fermenting unit. Culture tank design aids interchangeability, reducing downtime during off-site sterilisation....
Autoclavable glass fermenter T-S222GFS
Autoclavable glass fermenter is a mechanically driven stirred-tank bench top fermenting unit. Culture tank design aids interchangeability, reducing downtime during off-site sterilisation....
Autoclavable glass fermenter T-S221GFS
Autoclavable glass fermenter is mechanically driven stirred-tank bench top fermenting unit. Culture tank design aids interchangeability, reducing downtime during off-site sterilisation. T...
Autoclavable glass fermenter T-S220GFS
Autoclavable glass fermenter is mechanically driven stirred-tank bench top fermenting unit. Culture tank design aids interchangeability, reducing downtime during off-site sterilisation. T...
Autoclavable glass fermenter T-S237GFS
Autoclavable glass fermenter is mechanically driven stirred-tank bench top fermenting unit. Culture tank design aids interchangeability, reducing downtime during off-site sterilisation. T...
Autoclavable glass fermenter T-S236GFS
Autoclavable glass fermenter is mechanically driven stirred-tank bench top fermenting unit. Culture tank design aids interchangeability, reducing downtime during off-site sterilisation. T...
Autoclavable glass fermenter T-S235GFS
Autoclavable glass fermenter is mechanically driven stirred-tank bench top fermenting unit. Culture tank design aids interchangeability, reducing downtime during off-site sterilisation. T...
Autoclavable glass fermenter T-S234GFS
Autoclavable glass fermenter is mechanically driven stirred-tank bench top fermenting unit. Culture tank design aids interchangeability, reducing downtime during off-site sterilisation. T...
Autoclavable glass fermenter T-S233GFS
Autoclavable glass fermenter is mechanically driven stirred-tank bench top fermenting unit. Culture tank design aids interchangeability, reducing downtime during off-site sterilisation. T...
Autoclavable glass fermenter T-S232GFS
Autoclavable glass fermenter is mechanically driven stirred-tank bench top fermenting unit. Culture tank design aids interchangeability, reducing downtime during off-site sterilisation. T...
Autoclavable glass fermenter T-S231GFS
Autoclavable glass fermenter is mechanically driven stirred-tank bench top fermenting unit. Culture tank design aids interchangeability, reducing downtime during off-site sterilisation. T...
Autoclavable glass fermenter T-S230GFS
Autoclavable glass fermenter is mechanically driven stirred-tank bench top fermenting unit. Culture tank design aids interchangeability, reducing downtime during off-site sterilisation. T...
Autoclavable glass fermenter T-S217GFS
Autoclavable glass fermenter is a magnetically driven stirred-tank bench top fermenting unit. Culture tank design aids interchangeability, reducing downtime during off-site sterilisation....
Autoclavable glass fermenter T-S216GFS
Autoclavable glass fermenter is a magnetically driven stirred-tank bench top fermenting unit. Culture tank design aids interchangeability, reducing downtime during off-site sterilisation....
Autoclavable glass fermenter T-S215GFS
Autoclavable glass fermenter is a magnetically driven stirred-tank bench top fermenting unit. Culture tank design aids interchangeability, reducing downtime during off-site sterilisation....
Autoclavable glass fermenter T-S214GFS
Autoclavable glass fermenter is a magnetically driven stirred-tank bench top fermenting unit. Culture tank design aids interchangeability, reducing downtime during off-site sterilisation....
Autoclavable glass fermenter T-S213GFS
Autoclavable glass fermenter is a magnetically driven stirred-tank bench top fermenting unit. Culture tank design aids interchangeability, reducing downtime during off-site sterilisation....
Autoclavable glass fermenter T-S212GFS
Autoclavable glass fermenter is a magnetically driven stirred-tank bench top fermenting unit. Culture tank design aids interchangeability, reducing downtime during off-site sterilisation....
Autoclavable glass fermenter T-S210GFS
Autoclavable glass fermenter is a magnetically driven stirred-tank bench top fermenting unit. Culture tank design aids interchangeability, reducing downtime during off-site sterilisation....
Autoclavable glass fermenter T-S211GFS
Autoclavable glass fermenter is a magnetically driven stirred-tank bench top fermenting unit. Culture tank design aids interchangeability, reducing downtime during off-site sterilisation....
Standards
ASME BPE-2022-Bioprocessing Equipment
Complies with the above standards, but is not limited to them.
Features
1. Bench, pilot and production models cover scale-up needs.
2. Safety devices protect against over-pressure and over-temperature.
3. Controlled agitation, aeration, temperature and pH support growth.
4. Pumps and feed lines support controlled addition.
5. Data export supports batch and scale-up records.
FAQ
What are the main applications of the Autoclavable Glass Fermenter?
The Autoclavable Glass Fermenter is used to culture microorganisms or cells under controlled conditions for research, process development and production. It supports biotechnology, pharmaceutical, food and industrial microbiology laboratories.
What standards does the Autoclavable Glass Fermenter comply with?
The system is designed with reference to IEC 61010 electrical safety, pressure and bioprocess practice and relevant GB/T standards. Sterilisation and control should follow validated procedures. Compliance documentation can be provided on request.
How long is the warranty period?
The complete unit carries a 12-month warranty from delivery, covering the main body, core components and controller against manufacturing defects. Consumables and wearing parts such as filters, seals and probes are not covered. Damage from misuse, improper power or unauthorised repair is excluded, and extended warranty can be quoted.
Is the Autoclavable Glass Fermenter difficult to operate?
The controls are designed for regular laboratory use, so most users become confident after a brief introduction. The manual walks through each step, and common settings can be saved for repeat work. Online or on-site training is available if the site requires it.
What is the typical lead time for order delivery?
Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.
How often should the Autoclavable Glass Fermenter be calibrated?
The unit is calibrated and tested before delivery. For ongoing accuracy, verify it against traceable reference standards every 6 to 12 months, or according to the laboratory quality schedule. We can arrange calibration service and certificates where required.
Are the consumables universal or proprietary?
No proprietary consumable contract is required; standard parts are available from us and common laboratory suppliers. Our service team can supply a recommended parts list for the model. Most routine spares are held for quick delivery.
Can it be adapted to our requirements?
The standard model can be configured with selected accessories and operating options to suit the task. Non-standard requests are assessed before quotation so the final build is clearly defined. We confirm details before production.
Is installation and commissioning included?
Benchtop and standard units typically require only placement and connection before use, while larger systems may need professional commissioning. We confirm the installation requirements at order stage. On-site service and training can be provided if needed.
What maintenance and safety points matter?
Do not run without sterilisation and proper seals, exceed temperature or agitation limits or ignore contamination checks. Follow bioprocess safety rules.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.