Introduction

FTIR (Fourier Transform Infrared) Spectrometers feature high-resolution infrared detection for detailed and accurate molecular analysis. They provide broad spectral coverage and ensure stable signal-to-noise performance for consistent measurement reliability. Their advanced interferometry allows for precise, repeatable absorption analysis across a wide range of samples. These systems incorporate compact structures and user-friendly controls to streamline laboratory workflows. Ideal for chemical, pharmaceutical, and material science applications requiring in depth spectral characterization.

FTIR Spectrometer T-S210FTIR

FTIR Spectrometer T-S210FTIR


FTIR Spectrometer is a microprocessor controlled single beam spectrometer. It is characterized with precision machinery ensuring high integration scanning of optical path. The corner cube...

Standards

ASTM E1421-99(2021)-Standard Practice for Describing and Measuring Performance of Fourier Transform Mid-Infrared (FT-MIR) Spectrometers: Level Zero and Level One Tests

ASTM E1944-98(2021)-Standard Practice for Describing and Measuring Performance of Laboratory Fourier Transform Near-Infrared (FT-NIR) Spectrometers: Level Zero and Level One Tests

ISO 19702:2024-Guidance for sampling and analysis of toxic gases and vapours in fire effluents using Fourier Transform Infrared (FTIR) spectroscopy

Complies with the above standards, but is not limited to them.

Features

1. Cuvette holders and accessories suit different sample types.

2. Multi-cell or sipper options increase measurement throughput.

3. Software tools support spectral scans, standard curves and kinetics.

4. Low stray-light design supports accurate absorbance readings.

5. Diffraction grating or monochromator provides precise wavelength selection.

FAQ

What is the Fourier Transform Infrared Spectrometer mainly used for?

The Fourier Transform Infrared Spectrometer is used to measure absorbance, transmittance or concentration of samples across a defined wavelength range. It supports quantitative analysis, purity checks, kinetics and quality control in chemistry, biology, pharmaceutical and environmental laboratories.

Which standards and regulations apply to the Fourier Transform Infrared Spectrometer?

The instrument is designed with reference to IEC 61010 electrical safety requirements and relevant GB/T standards for spectrophotometers, including wavelength and photometric accuracy. Procedures should follow applicable standard methods. Compliance documentation can be provided on request.

How long is the warranty period?

A 12-month warranty applies to the complete equipment against defects in materials and workmanship. It excludes consumables, wearing components and accidental or misuse damage. Our service team handles claims against the serial number, and longer cover can be arranged.

Will staff need special training?

Routine operation is straightforward and is covered in the user manual, including setup, daily use and basic maintenance. Staff with basic laboratory experience can run it after a short familiarisation. We provide remote guidance and can arrange on-site training where required.

How long does delivery usually take?

Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.

Is calibration included?

Regular calibration keeps measurements within the stated accuracy; an annual check is typical, with shorter intervals for heavy or regulated use. Reference standards and procedures are described in the manual. We can quote calibration with certificates.

Where do we get replacement parts?

Filters, seals, probes and similar items are standard and can be supplied through our channel. Customers may also source equivalent items that meet the specification. Provide the model and serial number to confirm compatibility before ordering.

Can the Fourier Transform Infrared Spectrometer be customised?

Customisation is supported for many installations, including tailored parameters, connections and accessories. Our team reviews the requirement and confirms feasibility and lead time in advance. We avoid committing to options that cannot be delivered reliably.

Is installation and commissioning included?

The unit is delivered ready for set-up, with clear commissioning steps in the manual. We provide remote technical support during installation. For larger or regulated systems, a factory-trained engineer can attend on site on request.

What should be avoided when using the Fourier Transform Infrared Spectrometer?

Do not measure highly corrosive or incompatible samples, use dirty cuvettes or skip blank correction. Verify wavelength and photometric accuracy periodically. Follow laboratory safety rules.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.

Inquiry