Introduction

Fluorescence spectrophotometer is an advanced analytical instrument designed to measure the emission of fluorescent light from a sample following its excitation with a specific wavelength of light. It's widely used in fields like molecular biology, chemistry, and environmental science to analyze fluorescent compounds, including biomolecules, dyes, and pollutants. They provide valuable insights into the chemical and biological properties of substances by measuring the intensity and wavelength of emitted fluorescence, aiding in research, diagnostics, and quality control across multiple industries. Measurement accuracy: ±0.01 pH; range: 0.00 to 14.00 pH.

Fluorescence Spectrophotometer T-FSP-S2102

Fluorescence Spectrophotometer T-FSP-S2102

Fluorescence Spectrophotometer offers wavelength range of 200 to 900 nm. It features horizontal slit design for high luminous detection and signal-to-noise ratio. Equipped with photoelectr...
Fluorescence Spectrophotometer T-FSP-S2101

Fluorescence Spectrophotometer T-FSP-S2101

Fluorescence Spectrophotometer provides excitation and emission wavelengths from 200nm to 900nm. It offers scanning speeds up to 48,000nm/min for efficient result acquisition. It features ...
Fluorescence Spectrophotometer T-FSP-S2100

Fluorescence Spectrophotometer T-FSP-S2100

Fluorescence Spectrophotometer offers a wavelength range from 250 to 700 nm. It provides a signal-to-noise ratio higher than 150 for detection of low-intensity readings through 1 cm quartz...
Fluorescence Spectrophotometer T-S210FLS

Fluorescence Spectrophotometer T-S210FLS


Fluorescence Spectrophotometer is a multifunctional light excitation and emission detector device. It operates over a linear range of working curve for systematic output. It features full...
Fluorescence Spectrophotometer T-S211FLS

Fluorescence Spectrophotometer T-S211FLS


Fluorescence Spectrophotometer is a multifunction light excitation and emission detector device with eight stages of sensitivity adjustments. Cold-light source LED with longevity and reli...

Standards

European Pharmacopoeia 2.2.25-Spectrophotometry, ultraviolet and visible

ASTM E275-08(2022)-Standard Practice for Describing and Measuring Performance of Ultraviolet, Visible, and Near-Infrared Spectrophotometers

ASTM E579-20-Standard Test Method for Limit of Detection and Limit of Quantification in Fluorescence Measurements of Solutions

Complies with the above standards, but is not limited to them.

Features

1. Software tools support spectral scans, standard curves and kinetics.

2. Low stray-light design supports accurate absorbance readings.

3. Cuvette holders and accessories suit different sample types.

4. Wide wavelength range covers common analytical applications.

5. Quality optical system delivers accurate wavelength and photometric results.

FAQ

What is the Fluorescence Spectrophotometer mainly used for?

The Fluorescence Spectrophotometer is used to measure absorbance, transmittance or concentration of samples across a defined wavelength range. It supports quantitative analysis, purity checks, kinetics and quality control in chemistry, biology, pharmaceutical and environmental laboratories.

Which standards and regulations apply to the Fluorescence Spectrophotometer?

The instrument is designed with reference to IEC 61010 electrical safety requirements and relevant GB/T standards for spectrophotometers, including wavelength and photometric accuracy. Procedures should follow applicable standard methods. Compliance documentation can be provided on request.

What warranty comes with the Fluorescence Spectrophotometer?

A 12-month warranty applies to the complete equipment against defects in materials and workmanship. It excludes consumables, wearing components and accidental or misuse damage. Our service team handles claims against the serial number, and longer cover can be arranged.

Will staff need special training?

No advanced specialist skills are needed for standard operation, though correct sample handling and safety practice should be followed. We supply a detailed manual and start-up support. For multi-user or regulated sites, a short staff training session can be arranged.

What is the typical lead time for order delivery?

Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.

Does the Fluorescence Spectrophotometer need calibration or verification?

The unit is calibrated and tested before delivery. For ongoing accuracy, verify it against traceable reference standards every 6 to 12 months, or according to the laboratory quality schedule. We can arrange calibration service and certificates where required.

Where do we get replacement parts?

Common consumables and standard spare parts are available through our service channel and are not locked to proprietary formats. Quote the model and serial number when ordering so the correct items are supplied. Lead time for standard parts is usually short.

Can the Fluorescence Spectrophotometer be customised?

Yes, common options include different ranges, voltages, accessories, interfaces and capacity or size configurations. We confirm feasibility, specifications and any delivery impact before order confirmation. Custom requirements are reviewed case by case.

Do you provide on-site installation?

Benchtop and standard units typically require only placement and connection before use, while larger systems may need professional commissioning. We confirm the installation requirements at order stage. On-site service and training can be provided if needed.

What maintenance and safety points matter?

Do not measure highly corrosive or incompatible samples, use dirty cuvettes or skip blank correction. Verify wavelength and photometric accuracy periodically. Follow laboratory safety rules.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.

Inquiry