Introduction

An oxidation stability tester is a laboratory instrument designed to assess the ability of fuels, oils, and other hydrocarbon-based substances to resist oxidative degradation over time. This device exposes a sample to controlled conditions, including elevated temperature and the presence of oxygen or other oxidizing agents, to accelerate the aging process. By monitoring changes in various parameters such as acidity, peroxide levels, or viscosity, it measures the sample's resistance to oxidation and predicts its long-term stability and potential for degradation. Oxidation stability testers are widely used in the petroleum, chemical, and food industries to ensure the quality and longevity of products like engine oils, biodiesel, and edible oils. They play a critical role in quality control, product development, and compliance with industry standards, helping to prevent issues related to oxidation and degradation in various applications.

Mineral Oil Oxidation Stability Tester T-S210MOS

Mineral Oil Oxidation Stability Tester T-S210MOS


Mineral Oil Oxidation Stability Tester operates within a temperature control range of room temperature to 160 °C. It features six individual flow meters for precise control of gas flow i...
Greases Oxidation Stability Tester T-S210GOST

Greases Oxidation Stability Tester T-S210GOST


Greases oxidation stability tester is an automated unit with oxygen pressure measurement system. Touch screen panel records and displays test value for convenient use. Conforms to ASTM D9...
Gasoline Oxidation Stability Tester T-S210GOS

Gasoline Oxidation Stability Tester T-S210GOS


Gasoline oxidation stability tester is an automated unit. It detects the oxidation stability of finished gasoline under accelerated oxidated environment. Integrated standard water bath en...
Gasoline Oxidation Stability Tester T-S211GOS

Gasoline Oxidation Stability Tester T-S211GOS


Gasoline oxidation stability tester is an automated unit. It detects the oxidation stability of finished gasoline under accelerated oxidated environment. Integrated standard water bath en...
Gasoline Oxidation Stability Tester T-S212GOS

Gasoline Oxidation Stability Tester T-S212GOS


Gasoline oxidation stability tester is an automated unit. It detects the oxidation stability of finished gasoline under accelerated oxidated environment. Integrated standard water bath en...
Distillate Fuel Oil Oxidation Stability Tester T-S213DOS

Distillate Fuel Oil Oxidation Stability Tester T-S213DOS


Distillate fuel oil oxidation stability tester is a microprocessor controlled unit with oxygen flow meter for testing the inherent stability of fuels. The intelligent temperature control ...
Distillate Fuel Oil Oxidation Stability Tester T-S212DOS

Distillate Fuel Oil Oxidation Stability Tester T-S212DOS


Distillate fuel oil oxidation stability tester is a microprocessor controlled unit designed under ASTM D2274 standard. Its auxiliary heating power and flowmeters ensures distinct flow con...
Distillate Fuel Oil Oxidation Stability Tester T-S210DOS

Distillate Fuel Oil Oxidation Stability Tester T-S210DOS


Distillate fuel oil oxidation stability tester is a digital testing apparatus. Integrated PID controller ensures precise control of temperature. It is equipped with stainless steel tube w...
Distillate Fuel Oil Oxidation Stability Tester T-S211DOS

Distillate Fuel Oil Oxidation Stability Tester T-S211DOS


Distillate fuel oil oxidation stability tester is a digital testing apparatus. Integrated PID controller ensures precise control of temperature. It is equipped with stainless steel tube w...

Standards

Complies with the above standards, but is not limited to them.

Features

1. Durable construction suits routine laboratory use.

2. Compact dimensions and light weight ease bench placement.

3. Accessories and consumables are available through our channel.

4. Clear controls and display support straightforward operation.

5. Pre-set routines shorten set-up for repeated standard procedures.

FAQ

What are the main applications of the Oxidation Stability Tester?

The Oxidation Stability Tester is used for a defined laboratory measurement, preparation or processing task. It supports analytical, quality-control, research, clinical or industrial work where consistent, repeatable results are required.

What standards does the Oxidation Stability Tester comply with?

The instrument is designed with reference to IEC 61010 electrical safety, the applicable international standard for the measurement or process and relevant GB/T standards. Procedures should follow the relevant method. Compliance documentation can be provided on request.

What warranty comes with the Oxidation Stability Tester?

We provide a 12-month limited warranty on the instrument and its key working parts. Consumables, accessories and parts subject to normal wear are excluded, as is damage caused by incorrect operation or maintenance. An extended service plan is available on request.

Is the Oxidation Stability Tester difficult to operate?

Day-to-day use is simple, with clear prompts and pre-set functions reducing manual steps. New operators should review the manual and complete a short familiarisation. Our technical team offers remote support during the first runs.

What is the typical lead time for order delivery?

Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.

Is calibration included?

The unit is calibrated and tested before delivery. For ongoing accuracy, verify it against traceable reference standards every 6 to 12 months, or according to the laboratory quality schedule. We can arrange calibration service and certificates where required.

Are consumables and spare parts easy to obtain?

No proprietary consumable contract is required; standard parts are available from us and common laboratory suppliers. Our service team can supply a recommended parts list for the model. Most routine spares are held for quick delivery.

Can it be adapted to our requirements?

Customisation is supported for many installations, including tailored parameters, connections and accessories. Our team reviews the requirement and confirms feasibility and lead time in advance. We avoid committing to options that cannot be delivered reliably.

Do you provide on-site installation?

Most models can be commissioned by following the manual, including positioning, connections, checks and a first test run. Remote guidance is available during start-up. On-site installation, commissioning and training can be arranged separately where required.

What should be avoided when using the Oxidation Stability Tester?

Do not use the instrument outside its rated range or intended samples, skip calibration or ignore safety and maintenance instructions. Follow the operating manual and laboratory safety rules.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.