Introduction
Motor Lift Rotary Evaporators feature motorized lifting mechanisms for smooth and effortless flask adjustments. They support a wide range of evaporation capacities while maintaining stable temperature and vacuum control throughout the process. Their rotating flasks, paired with durable condensers, enable efficient solvent recovery and continuous sample concentration. They offer consistent rotation speeds and hands-free operation for reliable and repeatable evaporation. These systems are ideal for laboratories requiring precision and convenience in automated workflows.
Motor lift rotary evaporator T-S268MRE
Motor lift rotary evaporator is equipped with a 1 L ball grinding mouth receiving flask and a 2 L evaporating flask. It features a motor automatic lifting mode with a lifting height in th...
Motor lift rotary evaporator T-S269MRE
Motor lift rotary evaporator is equipped with a 1 L ball grinding mouth receiving flask and a 2 L evaporating flask. It features a motor automatic lifting mode with a lifting height in th...
Motor lift rotary evaporator T-S265MRE
Motor lift rotary evaporator is equipped with a 30 L evaporating flask. It has a condensate area of 1.2 m2 and it features a flask rotation speed of 0 rpm to 120 rpm. It consists of a PID...
Motor lift rotary evaporator T-S266MRE
Motor lift rotary evaporator is equipped with a 50 L evaporating flask. It has a condensate area of 1.2 m2 and it features a flask rotation speed of 0 rpm to 120 rpm. It consists of a PID...
Motor lift rotary evaporator T-S267MRE
Motor lift rotary evaporator is equipped with a 1 L ball grinding mouth receiving flask and a 2 L evaporating flask. It features a motor automatic lifting mode with a lifting height in th...
Motor lift rotary evaporator T-S262MRE
Motor lift rotary evaporator is equipped with a 5 L evaporating flask. It consists of a PID temperature controller that assures accurate temperature control. Features a flask rotation spe...
Motor lift rotary evaporator T-S263MRE
Motor lift rotary evaporator is equipped with a 10 L evaporating flask. It has a condensate area of 0.6 m2 and it features a flask rotation speed of 0 rpm to 120 rpm. It consists of a PID...
Motor lift rotary evaporator T-S264MRE
Motor lift rotary evaporator is equipped with a 20 L evaporating flask. It has a condensate area of 0.9 m2 and it features a flask rotation speed of 0 rpm to 120 rpm. It consists of a PID...
Motor lift rotary evaporator T-S260MRE
Motor lift rotary evaporator is equipped with a 0.5 L to 2 L evaporating flask. It consists of a PID temperature controller that assures accurate temperature control. Features a flask rot...
Motor Lift Rotary Evaporator T-S261MRE
Motor lift rotary evaporator is equipped with a 3 L evaporating flask. It consists of a PID temperature controller that assures accurate temperature control. Features a flask rotation spe...
Standards
ISO 3585:1998-Borosilicate glass 3.3-Properties
Complies with the above standards, but is not limited to them.
Features
1. Standard glass assemblies follow common analytical methods.
2. Clear controls show temperature and time.
3. Multiple-position design processes several samples in one run.
4. Tool-free glass assembly and disassembly speed changeover.
5. Clear method presets align with common analytical standards.
FAQ
What are the main applications of the Motor Lift Rotary Evaporator?
The Motor Lift Rotary Evaporator is used for a defined chemical preparation step such as digestion, extraction, evaporation or distillation. It supports analytical, environmental, food, pharmaceutical and teaching laboratories following standard procedures.
What standards does the Motor Lift Rotary Evaporator comply with?
The apparatus is designed with reference to IEC 61010 electrical safety and relevant ISO and GB/T standard methods for the specific procedure. Glassware and heating must match the method. Compliance documentation can be provided on request.
How long is the warranty period?
A 12-month warranty applies to the complete equipment against defects in materials and workmanship. It excludes consumables, wearing components and accidental or misuse damage. Our service team handles claims against the serial number, and longer cover can be arranged.
Is the Motor Lift Rotary Evaporator difficult to operate?
Day-to-day use is simple, with clear prompts and pre-set functions reducing manual steps. New operators should review the manual and complete a short familiarisation. Our technical team offers remote support during the first runs.
How long does delivery usually take?
Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.
Does the Motor Lift Rotary Evaporator need calibration or verification?
The unit is calibrated and tested before delivery. For ongoing accuracy, verify it against traceable reference standards every 6 to 12 months, or according to the laboratory quality schedule. We can arrange calibration service and certificates where required.
Are consumables and spare parts easy to obtain?
The instrument uses standard, widely available consumables rather than special locked items. Replacement parts, accessories and consumables can be ordered from us against the model number. We keep common service parts in stock for prompt supply.
Are options or configurations available?
Customisation is supported for many installations, including tailored parameters, connections and accessories. Our team reviews the requirement and confirms feasibility and lead time in advance. We avoid committing to options that cannot be delivered reliably.
Is installation and commissioning included?
The unit is delivered ready for set-up, with clear commissioning steps in the manual. We provide remote technical support during installation. For larger or regulated systems, a factory-trained engineer can attend on site on request.
What maintenance and safety points matter?
Do not use incompatible or damaged glassware, exceed temperature or pressure limits or work without ventilation for fuming samples. Follow the standard method and safety rules.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.