Introduction
An orbital shaker is a laboratory instrument designed for gently and consistently agitating liquid samples. It features a flat platform that moves in a circular or orbital motion to provide thorough mixing and aeration. These shakers are widely used in life sciences and chemistry applications for cell culture, staining, hybridization, and other tasks requiring uniform agitation. They come with adjustable speed and time controls, enabling precise customization of shaking parameters. orbital shakers are essential tools for researchers and scientists, ensuring the reliability and reproducibility of experiments by promoting even distribution of samples in various vessels like flasks, culture dishes, and microplates.
Orbital Shaker T-ORS-S2106
Orbital Shaker T-ORS-C101
Orbital Shaker T-ORS-C100
Orbital Shaker T-ORS-S2105
Orbital Shaker T-ORS-S2104
Decolorization Orbital Shaker T-DOS-S2102
Decolorization Orbital Shaker T-DOS-S2101
Decolorization Orbital Shaker T-DOS-S2100
Orbital Shaker T-ORS-S2103
Orbital Shaker T-ORS-L2100
Orbital Shaker T-ORS-S2102
Orbital Shaker T-ORS-S2101
Orbital Shaker T-ORS-S2100
Digital Orbital Shaker T-OS-S2101
Digital Orbital Shaker T-OS-S2102
Digital Orbital Shaker T-OS-S2100
Multi-Functional Orbital Shaker T-MOS-1100
Flask Orbital Shaker T-FOS-1100B
Flask Orbital Shaker T-FOS-1100A
Flask Orbital Shaker T-FOS-1100
Orbital Shaker T-S214OS
Orbital Shaker features a shaking speed range of 50 to 250 rpm with a 20 mm orbit for gentle and reliable agitation. It features advanced microprocessor control with forwards or reverse s...
Orbital Shaker T-S213OS
Orbital Shaker operates at a shaking speed range of 50 to 300 rpm with a 10 mm orbit for smooth and consistent agitation. It accommodates up to 8 petri dishes or multiple conical flasks, ...
Orbital Shaker T-S232OS
Orbital Shaker operates in a gyratory motion, facilitating thorough mixing and agitation of samples. It utilizes natural convection mode for efficient heat distribution and uniformity. sh...
Orbital Shaker T-S220OS
Orbital Shaker is a compact and tabletop unit. Features brushless DC motor for smooth and quiet operation. LCD display for speed and time. IP21 protection class to ensure safe and reliabl...
Orbital Shakers T-S212OS
Orbital Shakers is a benchtop unit that provides smooth, continuous motion for uniform mixing of chemical and biological samples. It features inbuilt DC brushless motor, adopted micro-com...
Orbital Shakers T-S211OS
Orbital Shakers is a benchtop unit that provides smooth, continuous motion for uniform mixing of chemical and biological samples. It features inbuilt DC brushless motor, adopted micro-com...
Orbital Shakers T-S210OS
Orbital Shakers is a benchtop unit that provides smooth, continuous motion for uniform mixing of chemical and biological samples. It features inbuilt DC brushless motor, adopted micro-com...
Orbital Shakers T-S230OS
Orbital shaker is a well-designed, robust shaker with a large mounting surface and a load holding capacity of up to 12 kg. It is suitable for glassware’s with more than 250 ml of volume ...
Orbital Shakers T-S231OS
Orbital shaker is a well-designed, robust shaker with a large mounting surface and a load holding capacity of up to 12 kg. It is suitable for glassware’s with more than 250 ml of volume ...
Standards
IEC 61010-2-051:2018-Particular requirements for laboratory equipment for mixing and stirring
Complies with the above standards, but is not limited to them.
Features
1. Platform accessories accept tubes, flasks, bottles and microplates.
2. Wide speed range handles gentle re-suspension through vigorous aeration.
3. Timer and continuous modes support unattended runs.
4. Brushless motor provides quiet, maintenance-free operation.
5. Compact, stable base resists walking at higher speeds.
FAQ
What is the Orbital shaker mainly used for?
The Orbital shaker is used to mix, agitate, blend or aerate samples and media. It supports sample preparation, culturing, extraction and quality control in biology, chemistry, food, pharmaceutical and clinical laboratories.
Which standards and regulations apply to the Orbital shaker?
The unit is designed with reference to IEC 61010 electrical safety and relevant GB/T standards for laboratory mixing equipment. Procedures should follow the applicable methods. Compliance documentation can be provided on request.
How long is the warranty period?
The system is covered for 12 months after shipment, including the main mechanism and electrical controls. Replaceable consumables and routine service items are not part of the warranty. Faults caused by improper installation outside the manual or unauthorised modification are not covered.
How easy is the Orbital shaker to use?
Day-to-day use is simple, with clear prompts and pre-set functions reducing manual steps. New operators should review the manual and complete a short familiarisation. Our technical team offers remote support during the first runs.
How long does delivery usually take?
Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.
Does the Orbital shaker need calibration or verification?
The unit is calibrated and tested before delivery. For ongoing accuracy, verify it against traceable reference standards every 6 to 12 months, or according to the laboratory quality schedule. We can arrange calibration service and certificates where required.
Where do we get replacement parts?
No proprietary consumable contract is required; standard parts are available from us and common laboratory suppliers. Our service team can supply a recommended parts list for the model. Most routine spares are held for quick delivery.
Are options or configurations available?
Yes, common options include different ranges, voltages, accessories, interfaces and capacity or size configurations. We confirm feasibility, specifications and any delivery impact before order confirmation. Custom requirements are reviewed case by case.
Do you provide on-site installation?
Standard installation is straightforward and supported by the manual and start-up documentation. Our technical team can guide staff remotely through checks and validation. On-site commissioning is available as a quoted service.
What maintenance and safety points matter?
Do not exceed the rated load or speed, run unbalanced or unsecured vessels, or use incompatible media. Secure containers and use slow start. Follow laboratory safety rules.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.