Introduction

Polarimeter provides accurate optical rotation measurements in chiral substances for purity analysis. They include a light source, polarizing elements, a sample tube, and an analyzer. These polarimeters are available in Digital Polarimeter, Manual Disc Polarimeter, and Semi-Automatic Polarimeter. They also include data output capabilities for easy connection to computers or printers for record-keeping. Our Polarimeter is ideal for applications in pharmaceuticals, food and beverage industries, and academic research.

Automatic Polarimeter T-S2PM-S2100

Automatic Polarimeter T-S2PM-S2100

Automatic Polarimeter operates at standard working wavelength of 589.3 nm. ensuring accurate and reliable optical rotation measurements. Integrated with Peltier temperature control system ...
Semi Automatic Polarimeter T-SAP-S2101

Semi Automatic Polarimeter T-SAP-S2101

Semi Automatic Polarimeter is designed for measuring the optical rotation of polarized light in optically active substances. Featuring a 5.6-inch TFT touchscreen for user-friendly operatio...
Manual Polarimeter T-MP-4010

Manual Polarimeter T-MP-4010

Manual Polarimeter is suitable for measuring the optical rotation of optically active substances which comes with 589 nm standard sodium lamp (-180) °C to 180 °C measurement range for de...
Manual Polarimeter T-S220POM

Manual Polarimeter T-S220POM


Manual Polarimeter features a ±180° measuring range for precise analysis of optically active substances. It accommodates sample tubes up to 200 mm and ensures accurate results with 0.05...
Polarimeter T-S212POM

Polarimeter T-S212POM


Polarimeter provides a measurement range of ±89.99° for optical rotation and up to ±259°Z for sugar content for reliable and versatile sample analysis. It operates within a temperatur...
Polarimeter T-S213POM

Polarimeter T-S213POM


Polarimeter features a measurement range of ±89.99° for optical rotation and up to ±259°Z for sugar content, enabling precise analysis. It maintains a temperature control range of 15 ...
Polarimeter T-S210POM

Polarimeter T-S210POM


Polarimeter features a measurement range of optical rotation of up to ±89.99° and sugar content of up to ±257°Z, ensuring precise analysis of optical activity and sugar levels. It pro...
Polarimeter T-S211POM

Polarimeter T-S211POM


Polarimeter operates within a measurement range of ± 89.99° for optical rotation and ± 259°Z for sugar content, ensuring precise and reliable analysis. It maintains a temperature cont...
Semi-Automatic Polarimeter SP20420

Semi-Automatic Polarimeter SP20420


Semi-Automatic Polarimeter is a multi-parameter device with 3 point calibration, the instrument is suitable for measuring the optical rotation, specific rotation, concentration and sugar ...
Manual Disc Polarimeter MP2042

Manual Disc Polarimeter MP2042


Manual Disc Polarimeter is a basic scientific instrument used to measure the optical rotation of optically active compound solutions with an accuracy of 0.05 degrees. It has a sample cham...
Digital Polarimeter DP2044

Digital Polarimeter DP2044


Digital Polarimeter is designed to operate at a precise wavelength of 589.3 nm. It encompasses various measurement modes such as rotation, specific curl, concentration, sugar content, and...
Digital Polarimeter DP2042

Digital Polarimeter DP2042


Digital Polarimeter includes an automatic calibration system ensuring long-term accuracy.It operates at a standard working wavelength of 589.3 nm, ensuring precise and consistent measurem...
Digital Polarimeter DP2041

Digital Polarimeter DP2041


Digital Polarimeter is designed to sustain a stable temperature range of 10–60°C, ensuring long-term accuracy. It features a large 8-inch TFT color touch screen for a user-friendly and ...

Standards

GB/T 613-2007-Chemical reagent-General method for the determination of specific optical rotation

Complies with the above standards, but is not limited to them.

Features

1. Data storage and export support quality records.

2. Precise temperature control supports reliable results.

3. LED illumination provides long life and stable light.

4. Stable optical system delivers accurate rotation readings.

5. Sample tubes of different lengths suit various applications.

FAQ

What is the Polarimeter mainly used for?

The Polarimeter is used to measure optical rotation of optically active substances, supporting purity, identity and concentration checks. It is used in sugar, pharmaceutical, chemical, food and essential-oil laboratories.

What standards does the Polarimeter comply with?

The instrument is designed with reference to IEC 61010 electrical safety and relevant GB/T standards for polarimetric measurement, with procedures following applicable pharmacopoeia and standard methods. Compliance documentation can be provided on request.

What does the warranty cover?

We provide a 12-month limited warranty on the instrument and its key working parts. Consumables, accessories and parts subject to normal wear are excluded, as is damage caused by incorrect operation or maintenance. An extended service plan is available on request.

How easy is the Polarimeter to use?

The controls are designed for regular laboratory use, so most users become confident after a brief introduction. The manual walks through each step, and common settings can be saved for repeat work. Online or on-site training is available if the site requires it.

What is the typical lead time for order delivery?

Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.

Is calibration included?

The unit is calibrated and tested before delivery. For ongoing accuracy, verify it against traceable reference standards every 6 to 12 months, or according to the laboratory quality schedule. We can arrange calibration service and certificates where required.

Where do we get replacement parts?

No proprietary consumable contract is required; standard parts are available from us and common laboratory suppliers. Our service team can supply a recommended parts list for the model. Most routine spares are held for quick delivery.

Can the Polarimeter be customised?

A range of options is available to match the application, such as alternative settings, fittings, data outputs or power supply. We confirm each option and its effect on price and schedule up front. Larger custom builds can be discussed.

Do you provide on-site installation?

Most models can be commissioned by following the manual, including positioning, connections, checks and a first test run. Remote guidance is available during start-up. On-site installation, commissioning and training can be arranged separately where required.

What maintenance and safety points matter?

Do not use cloudy or coloured samples beyond the method range, introduce bubbles or use a dirty tube. Control temperature, since rotation is temperature dependent. Follow the operating instructions.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.

Inquiry