Introduction

Synchronous Thermal Analyzer performs thermal analysis at temperatures ranging from room temperature to 1250°C. It supports a balance measurement range of 0.01 mg to 5 g, ensuring accurate weight detection. The heating rate adjusts from 0.1 to 100°C per minute for flexible testing. Its dual atmosphere control system ensures optimal experimental conditions for diverse materials. Designed for research laboratories, it is ideal for studying thermal stability, decomposition, and material composition.

This analytical equipment is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.

Applications

Our Synchronous Thermal Analyzer is used in material science, polymer research, and chemical industries. Ideal for phase transitions, decomposition, and adsorption studies, it suits both research and quality control.

Specifications

Temperature Range Room temperature to 1250°C
Temperature Resolution 0.01°C
Temperature Fluctuations ±0.01°C
Heating Rate 0.1 to 100°C/min
Balance Measurement Range 0.01 mg to 5 g
Quality Resolution 0.01 mg
Range 0 to ±2000 mW
Sensitivity 0.001 mW
Constant Temperature Time 0 to 500 min (adjustable)
Cooling Time 30 min (1000°C to 100°C)
Toggle Rate 16.6 Hz
Sample Rate 0.05 to 10 Hz (programmable)
Sensor Type K-type (standard), E-type (optional)
Experimental Modes and modes
Experimental Types Weight loss, weight gain (adsorption)
Program Temperature Control 12-stage flexible temperature settings
Temperature Control Heating, constant temperature, cooling
Number of Scans Up to 9999 cyclic scans with auto data save
Calibration Multi-point temperature correction
Display 7-inch 24-bit color touchscreen
Atmosphere Control Dual atmosphere switching
Power Supply AC 220V, 50Hz
Product Dimension 590 × 420 × 590 mm
Packaging Dimension 650 × 470 × 650 mm
Net Weight 40 kg
Gross Weight 45 kg

Features

High-frequency core control

Intelligent atmosphere control

Ceramic insulation furnace

Programmable cyclic scanning

Real-time 7-inch touchscreen

Multi-point temperature correction

Flexible sensor switching

Automatic report generation

FAQs

1. What are the key factors to consider when selecting this analytical equipment for laboratory use?

When selecting this analytical equipment, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.

2. How often should this analytical equipment be calibrated to ensure accurate results?

It is recommended to calibrate this analytical equipment at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.

3. What are the common maintenance procedures required for this analytical equipment?

Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.

4. Can this analytical equipment be used with different types of samples, and are there any compatibility considerations?

Yes, this analytical equipment can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.

5. What should be done if the analytical equipment malfunctions or produces inconsistent results?

If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.