Introduction
A conductivity analyzer is an instrument used to measure the electrical conductivity of the liquids, and it is used in the water treatment, the environmental monitoring, the process industry, and the many other applications for the monitoring and the control of the conductivity. The conductivity analyzer consists of a conductivity cell with the electrodes, a signal processing circuit, and a display, and it measures the conductivity by the measurement of the current flow between the electrodes in the solution, with the automatic temperature compensation, and it displays the conductivity value, expressed in microsiemens or millisiemens per centimeter, and it may provide the related parameters, such as the total dissolved solids (TDS) and the salinity; the conductivity analyzer is used for the monitoring of the conductivity of the water in the water treatment, for the monitoring of the concentration of the chemicals in the process industry, for the monitoring of the quality of the water, for the monitoring of the reverse osmosis and the demineralization systems, for the quality control, and for many other applications, and it is available as the benchtop, the portable, and the online analyzers, with features such as the calibration, the data logging, and the process control outputs; the conductivity analyzer is an essential instrument for the conductivity monitoring and the control. Conductivity analyzers are used in the water treatment plants, in the power plants, in the chemical industry, in the environmental monitoring, and for many other applications. With their conductivity measurement, conductivity analyzers are essential for the process monitoring.
Conductivity Analyzer LCVA-T2010
Conductivity Analyzer provides a conductivity measuring range of 0.00µS/cm to 199mS/cm, with indication error of 0.01µS/cm. Automatically selects the optimal conductivity range for acc...
Standards
IEC 60746-1:2003-Expression of performance of electrochemical analyzers-Part 1: General
USP General Chapter <645>-Water Conductivity
IEC 60746-3:2002-Expression of performance of electrochemical analyzers-Part 3: Electrolytic conductivity
Complies with the above standards, but is not limited to them.
Features
1. Conductivity analyzer for measuring electrical conductivity of liquids, indicating dissolved ion concentration and purity.
2. Benchtop or portable meter using conductivity cell (two/four-electrode) to measure solution conductivity in microsiemens or millisiemens.
3. Suitable for water treatment, pharmaceutical, food and beverage, chemical, environmental, semiconductor and laboratory use.
4. Includes analyzer body, conductivity cell/probe, temperature sensor, calibration standards, power and operation manual.
5. Supports conductivity, TDS (total dissolved solids), salinity and resistivity measurement in water and aqueous solutions.
FAQ
Q1: What testing scenarios is this analyzer mainly applied to?
A: The conductivity analyzer (conductivity meter) is used in water treatment, pharmaceutical, food and beverage, chemical, environmental, semiconductor, power, and research laboratories to measure the electrical conductivity of liquids, which indicates the concentration of dissolved ions (salts, acids, bases) and serves as an indicator of water purity, contamination, or process concentration. It supports water treatment (drinking water (monitor treatment efficiency, distribution system integrity, contamination), wastewater (influent/effluent quality, treatment process control, compliance), boiler/feedwater (monitor dissolved solids to prevent scaling/corrosion in boilers, cooling towers), deionized/RO water (verify purity of DI, RO, distilled water; low conductivity = high purity), pharmaceutical (purified water (PW) and water for injection (WFI) - conductivity is a critical quality attribute per USP <645>, EP 2.2.38, JP; must meet strict limits (WFI <1.3 microS/cm at 25 degrees C), clean-in-place (CIP) solutions (monitor concentration of caustic/acid cleaning solutions), food and beverage (process water quality, beverage formulation (monitor sugar/salt concentration indirectly), CIP rinse verification (residual cleaning agents), brewing (water quality for mashing/brewing), chemical (process solution concentration (acids, bases, salts), reaction monitoring, product quality, plating baths (electroplating solution concentration), environmental (surface water, groundwater, seawater (salinity via conductivity), stormwater, pollution monitoring (industrial discharge compliance), semiconductor (ultrapure water (UPW) for wafer fabrication - extremely low conductivity (18.2 Mohm-cm = 0.055 microS/cm at 25 degrees C), critical for chip manufacturing), power (steam/water cycle chemistry (monitor boiler water, condensate to prevent corrosion/scaling in turbines/boilers), and research/QC (solution preparation, chemical analysis, column chromatography (monitor eluent), buffer preparation, batch consistency). Conductivity is a fast, inexpensive, non-specific indicator of total dissolved ions - it does not identify specific ions (use ion chromatography for speciation), but is widely used for purity and process monitoring.
Q2: What standards does the analyzer comply with?
A: The conductivity analyzer follows relevant ISO, ASTM, USP/EP, IEC and GB/T standards including ISO 7888 (water quality - determination of electrical conductivity), ASTM D1125 (standard test methods for electrical conductivity and resistivity of water), ASTM D5391 (standard test method for electrical conductivity and resistivity of high-purity water), USP <645> (water conductivity - for pharmaceutical water (PW, WFI), specifies three-stage test), EP 2.2.38 (conductivity), IEC 60746 (expression of performance of electrochemical analyzers - conductivity), and GB/T standards for conductivity meters. The hardware complies with applicable accuracy standards (typically +/- 0.5-1% full scale or +/- 0.01 microS/cm for high-purity) and EMC standards (IEC 61326). Calibration uses certified conductivity standards (e.g., 0.01, 0.1, 1, 10, 100 mS/cm KCl solutions traceable to national standards) per ISO 7888/ASTM D1125. For pharmaceutical water, follow USP <645>/EP 2.2.38 (specific conductivity limits and temperature correction). For regulated industries, follow ISO 9001/GMP/ISO 17025 and maintain calibration records. For environmental monitoring, follow ISO 7888 and applicable regulatory methods (EPA, national standards).
Q3: What is the warranty period for the whole analyzer and key components?
A: The whole conductivity analyzer is covered by a 12-24 month warranty (analytical instruments often 2 years). The meter body, electronics, display, and temperature sensor are covered, while conductivity cell/probe (wear part - electrodes can foul, polarize, degrade; cell constant drifts over time; replaceable), calibration standards (consumable - expire), and batteries (portable) are consumables/accessories. Damage from improper use, probe fouling (oil, grease, biological growth on electrodes - affects readings; clean regularly), dry storage without protection, using wrong cell constant for range, liquid/corrosive ingress, dropping (portable), or unauthorized repair is excluded. Extended warranty and service contracts (calibration, probe replacement) may be available. Electronics last 5-10 years; conductivity cells need periodic replacement or recalibration (1-3 years depending on usage/fouling).
Q4: Is this device difficult to operate? Is professional training required?
A: Operation is straightforward for basic use (rinse probe, immerse in sample, read display). No professional training required for routine measurement, but proper technique and calibration are important for accuracy. We provide operation manuals. Proper setup (insert batteries (portable) or connect power (benchtop), turn on, allow warm-up (1-5 min for stabilization), select measurement mode (conductivity, TDS, salinity, resistivity), select cell constant (match probe: 0.01, 0.1, 1.0, 10.0 cm^-1; choose based on expected conductivity: low conductivity (pure water) = low cell constant (0.01, 0.1); high conductivity (seawater, process) = high cell constant (1.0, 10.0); using wrong cell constant gives large errors), ensure automatic temperature compensation (ATC) is on (conductivity is highly temperature-dependent (~2% per degree C for aqueous solutions); ATC normalizes to 25 degrees C; for USP <645> pharma water, temperature compensation is NOT used (measure actual conductivity at actual temperature and compare to temperature-specific table - stage 1 test)), calibration (calibrate with certified conductivity standard (choose standard close to expected sample conductivity; e.g., 1413 microS/cm (0.01 M KCl) for general, 100 microS/cm for pure water, 100 mS/cm for high conductivity; rinse probe with DI water then standard, immerse in standard (ensure no air bubbles on electrodes, stir gently), wait for stability, enter standard value, confirm calibration; for multi-point calibration (2-3 standards spanning range) for high accuracy; record calibration date, standard lot, operator), sample measurement (rinse probe with sample (to avoid dilution from residual rinse water), immerse probe in sample (ensure electrodes fully submerged, no air bubbles, no contact with container walls/bottom), stir gently or wait for equilibrium (for low conductivity, allow longer equilibration (1-2 min) as response is slower), read display (conductivity in microS/cm or mS/cm; TDS in mg/L (TDS = conductivity x conversion factor, typically 0.5-0.7 for natural waters; note TDS is an estimate, not direct measurement); salinity in ppt or PSU; resistivity in Mohm-cm (for pure water, resistivity = 1/conductivity)), repeat (2-3 measurements for precision; rinse between samples), post-measurement (rinse probe thoroughly with DI water, store properly (some probes require wet storage in KCl or DI water; others can be dry - follow manufacturer; do not store dry if electrode requires wet storage (can damage reference junction)), clean if fouled (use mild detergent, acid (0.1 M HCl) for mineral deposits, or enzyme cleaner for biological fouling; rinse well), maintenance (regular cleaning (after each use - rinse probe; weekly: clean probe if fouled, inspect cable/connector for corrosion), probe inspection (check for damage, fouling, loose wires; verify cell constant with standard), calibration (every 1-3 months for routine use, or before critical measurements; if probe is cleaned/replaced, recalibrate; for GMP/pharma, calibrate per SOP (often daily or before each batch)), battery check (portable - replace when low), troubleshooting (readings unstable (air bubbles on electrodes, low conductivity (slow response), temperature fluctuation, probe fouling - remove bubbles, wait longer, control temp, clean probe), readings too high (probe not rinsed (carryover from previous sample/standard), wrong cell constant, calibration standard wrong, TDS conversion factor wrong - rinse probe, verify cell constant, recalibrate, check TDS factor), readings too low (probe not fully submerged, air bubbles, fouled electrodes, cell constant too high for low conductivity, reference junction clogged - submerge fully, remove bubbles, clean probe, use appropriate cell constant), calibration fails (standard expired/contaminated, probe fouled/damaged, wrong standard value - use fresh standard, clean/replace probe, verify value), meter not turning on (batteries dead, corrosion in compartment, power issue - replace batteries, clean contacts), and safety (chemical hazard (samples may contain acids, bases, salts, wastewater - wear PPE (gloves, lab coat, eye protection); handle corrosive samples in fume hood; dispose per regulations), electrical (battery-powered safe; benchtop proper grounding; do not use with wet hands), probe handling (do not bend probe cable, do not scrape electrodes (can damage platinum coating), do not immerse beyond specified depth (some probes have depth limit)), do not measure non-aqueous liquids (conductivity meters are for aqueous solutions; organic solvents have very different properties and may damage probe), handle calibration standards as chemicals (KCl solutions - low hazard but dispose properly)) are important for accurate conductivity measurement.
Q5: What is the typical lead-time for order delivery?
A: Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.
Q6: Is regular calibration required? What is the recommended calibration cycle?
A: Calibration recommended every 1-3 months (or per quality system) using certified conductivity calibration standards (KCl solutions with known conductivity traceable to national standards; choose standards spanning measurement range: e.g., 100 microS/cm, 1413 microS/cm, 12.88 mS/cm; accuracy typically +/- 0.5-1% of reading or +/- 0.01 microS/cm for high-purity). If probe is cleaned, replaced, or readings seem off, recalibrate immediately. Routine verification with a standard before critical measurements (e.g., pharma water testing per USP <645> often requires daily verification or calibration). For ISO 17025/GMP labs, follow applicable calibration schedules and maintain records (calibration certificates, standard lot numbers, as-found/as-left data, cell constant, temperature). Conductivity cells drift over time due to electrode fouling, polarization, and wear - regular calibration is essential. For high-purity water (UPW, semiconductor), calibration is challenging (low conductivity standards are difficult to maintain) - use certified low-conductivity standards or calibrate at higher range and verify with resistivity; follow ASTM D5391. Temperature sensor calibration (for ATC) every 6-12 months with certified thermometer.
Q7: Are supporting consumables universal?
A: Conductivity cells/probes (replacement - specific to meter model (various cell constants, connector types; some are universal (BNC, banana plug), others proprietary (digital probes with memory); use manufacturer-approved probe for accurate calibration), calibration standards (KCl solutions - certified, available from lab supply (Hach, Mettler, Orion, Hanna, Ricca) - somewhat universal if concentration/certification matches, but use traceable certified standards), TDS standards (if TDS mode), storage solution (KCl 3 M for some probes - standard), cleaning solutions (mild detergent, 0.1 M HCl, enzyme cleaner - standard lab supplies), batteries (standard AA/9V), and cables/connectors are available from laboratory supply companies, though probes and digital cells are often meter-specific (use OEM or certified compatible to maintain accuracy and warranty). Long-term consumable cost includes probe replacement (periodic, $100-$500+) and calibration standards (regular purchase).
Q8: Can I customize parameters or supporting accessories?
A: Customization includes type (portable (battery-powered, handheld, field use - IP67 rated, rugged) or benchtop (lab use, higher precision, multi-parameter, data logging), or inline/process (continuous monitoring, 4-20 mA, digital comms, flow-through cell)), measurement parameters (conductivity only, or multi-parameter (conductivity + TDS + salinity + resistivity + temperature; some add pH, dissolved oxygen, ORP, ion concentration)), range/cell constant (multiple cell constants available (0.01 for UPW, 0.1 for pure water, 1.0 for general, 10.0 for seawater/high conductivity); auto-ranging), precision (basic (+/- 1% full scale) to high-precision (+/- 0.01 microS/cm for UPW, +/- 0.5% reading)), display/control (basic (LED, conductivity only) or advanced (color display, graphing, data logging (1000+ points), USB/Bluetooth/WiFi/Ethernet export, PC software, GLP/GMP compliance (user ID, calibration records, 21 CFR Part 11)), probes (various cell constants, materials (epoxy (rugged, general), glass (chemical resistance, high temp), stainless steel (high pressure/temp, sanitary)), temperature sensor (Pt100/Pt1000 for ATC), connector (analog BNC or digital (smart probe with calibration memory)), accessories (calibration standards (multiple values), probe stand, flow-through cell, carrying case (portable), spare probes, printer, calibration certificate (ISO 17025), certifications (CE, FCC, ISO 9001, USP <645> compliance, ATEX (for hazardous areas, process models)), language and accessories. Additional probes, standards, and accessories can be ordered separately.
Q9: Does the purchase include on-site installation and commissioning service?
A: Standard delivery includes conductivity analyzer, conductivity cell/probe, calibration standard(s) (sometimes), power cord/batteries, and instruction manual. On-site installation is not required for portable/benchtop meters (ready to use - calibrate with standard, measure). On-site training is not included for standard orders but can be arranged at additional cost (for QC teams on proper calibration, USP <645> pharma water testing, GMP compliance). For inline/process conductivity analyzers: on-site installation, commissioning, and calibration ARE typically included or strongly recommended (requires plumbing integration, electrical wiring (4-20 mA, digital comms), configuration, and user training; installation by manufacturer or certified technician is standard). Always calibrate with certified standard before measuring samples.
Q10: What types of samples are compatible with this equipment?
A: The conductivity analyzer measures electrical conductivity of aqueous solutions including water (drinking water, purified water (PW), water for injection (WFI), deionized (DI) water, reverse osmosis (RO) water, distilled water, ultrapure water (UPW), natural water (river, lake, groundwater), seawater, wastewater (influent, effluent, treated), boiler water, cooling water, process water), chemical solutions (acids (dilute), bases (dilute), salts, buffer solutions, plating baths, cleaning solutions (CIP caustic/acid)), food and beverage (beverages, brewing water, process water, CIP rinse water), and other aqueous solutions. NOT compatible with: Non-aqueous liquids (organic solvents, oils - conductivity meters designed for aqueous; organic solvents have very low conductivity and different properties; may damage probe or give meaningless readings), highly viscous liquids (may not reach electrode surface properly), liquids with suspended solids/particles (can foul/abrade electrodes; filter if needed, or use contactless inductive conductivity sensor for dirty liquids), oils/greases (coat electrodes, cause fouling; clean thoroughly), extremely high conductivity beyond range (>2000 mS/cm - concentrated acids/bases; use appropriate high-range cell or inductive sensor), and liquids that attack probe materials (verify chemical compatibility of probe body (epoxy, glass, stainless) and electrodes (platinum, graphite) with sample; strong oxidizers, HF can damage electrodes). IMPORTANT: Conductivity analyzer fundamentals: (1) What it measures: Electrical conductivity (kappa) = ability of solution to conduct electric current via dissolved ions. Units: S/m (SI) or microS/cm, mS/cm (common). 1 S/m = 10 mS/cm = 10000 microS/cm. Resistivity (rho) = 1/conductivity, units Ohm-m or Mohm-cm. Pure water at 25 degrees C: 0.055 microS/cm (18.2 Mohm-cm). Drinking water: 50-800 microS/cm. Seawater: ~50 mS/cm (50000 microS/cm). Conductivity increases with ion concentration and temperature (~2% per degree C for aqueous). (2) How it works (contact conductivity): Two or four electrodes (platinum, graphite) in a cell. Apply AC voltage (to prevent polarization), measure current. Conductivity = cell constant (K, in cm^-1) x (current/voltage). Cell constant = distance between electrodes / electrode area. Two-electrode: simple, but prone to polarization at high conductivity. Four-electrode: better for high conductivity, less polarization. Inductive (electrodeless): for dirty/corrosive liquids, no electrode contact (uses toroidal coils), but less accurate for low conductivity. (3) Temperature compensation: Conductivity is highly temperature-dependent. Automatic Temperature Compensation (ATC) normalizes reading to 25 degrees C using temperature coefficient (typically 2%/degree C for neutral salts, but varies). For pure water, temperature coefficient is nonlinear (~4-5%/degree C). For pharmaceutical water (USP <645>), NO temperature compensation is used in stage 1 - measure actual conductivity at actual temperature and compare to temperature-specific limit table (e.g., at 20 degrees C: <2.4 microS/cm; at 25 degrees C: <1.3 microS/cm for WFI). (4) TDS (Total Dissolved Solids): Estimated from conductivity: TDS (mg/L) = conductivity (microS/cm) x conversion factor. Factor varies by water composition (0.5-0.7 for natural waters, 0.5 for NaCl, 0.7 for sulfate-rich). TDS is an approximation, not a direct gravimetric measurement. For accurate TDS, use gravimetric method (evaporate, weigh residue) or specific factor for water type. (5) Salinity: Derived from conductivity using practical salinity scale (PSS-78) for seawater. Units: PSU (practical salinity unit) or ppt. Seawater ~35 PSU. Conductivity meter with salinity mode calculates based on conductivity and temperature. (6) Calibration: Use certified KCl standards: - 0.001 M KCl = 146.93 microS/cm at 25 degrees C - 0.01 M KCl = 1413 microS/cm at 25 degrees C (most common) - 0.1 M KCl = 12.88 mS/cm at 25 degrees C - 1 M KCl = 111.3 mS/cm at 25 degrees C Calibrate with standard(s) close to expected sample conductivity. Multi-point calibration (2-3 standards) for best accuracy across range. Record cell constant (some meters auto-detect with smart probes). (7) Pharmaceutical water (USP <645>): Three-stage test: Stage 1: Measure conductivity (uncompensated) at actual temperature in a container with minimal atmospheric exposure; if below temperature-specific limit (e.g., 1.3 microS/cm at 25 degrees C for WFI), water meets requirement. Stage 2: If stage 1 fails, transfer sample to container, stir, measure conductivity while adding small amount of saturated KCl (to stabilize pH effect); if below limit, meets. Stage 3: If stage 2 fails, perform pH measurement and use conductivity/pH chart to determine compliance. This rigorous test ensures water purity for pharma use. (8) Common errors: - No/incorrect temperature compensation (biggest error for non-pharma; for pharma, using ATC when you should not (USP <645> requires uncompensated)). - Wrong cell constant (using 1.0 cell for pure water gives noisy/inaccurate readings; use 0.01/0.1). - Air bubbles on electrodes (cause unstable/high readings; tap probe to remove). - Not rinsing probe between samples (carryover contamination; rinse with sample before measurement). - Probe fouling (oil, biofilm, minerals - clean regularly; fouling increases resistance = low readings). - Calibration with wrong/expired standard (KCl standards absorb CO2 and change over time; use fresh, sealed standards). - Measuring pure water in open container (pure water rapidly absorbs CO2 from air, increasing conductivity from 0.055 to ~1 microS/cm; measure in closed/flow-through cell or quickly). - TDS conversion factor wrong (gives incorrect TDS estimate). - Not allowing equilibration (low conductivity samples respond slowly; wait 1-2 min). - Immersing probe too shallow (electrodes not fully submerged). (9) Choosing the right meter: - Pure water (PW, WFI, UPW): Need low cell constant (0.01, 0.1), high resolution (0.01 microS/cm), ATC or USP mode, flow-through cell (to avoid CO2 absorption). - General water: 1.0 cell constant, auto-ranging, ATC, portable or benchtop. - High conductivity (seawater, process): 10.0 cell constant or four-electrode/inductive sensor. - Dirty/corrosive: Inductive (electrodeless) sensor. - Field/portable: Rugged, waterproof, battery-powered, carrying case. - Process/inline: 4-20 mA output, digital comms, flow-through cell, hazardous area rating (ATEX). - Pharma/GMP: USP <645> compliance, calibration records, 21 CFR Part 11, IQ/OQ.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.