Introduction

An electrical conductivity tester is an instrument used to measure the electrical conductivity of the liquids and the other materials, and it is used in the water treatment, the agriculture, the hydroponics, the environmental monitoring, and the many other applications for the assessment of the dissolved ions and the quality. The electrical conductivity tester consists of a conductivity cell with the electrodes, a signal processing circuit, and a display, and it measures the conductivity by the measurement of the current flow between the electrodes in the solution, and it converts it to the conductivity value, expressed in microsiemens or millisiemens per centimeter, with the temperature compensation, and it displays the value; the electrical conductivity tester is available in various types, from the simple pen and the handheld testers to the benchtop and the laboratory meters, with the different ranges and the accuracies, and it is used for the measurement of the conductivity of the water and the solutions, for the monitoring of the dissolved solids, for the assessment of the water quality, for the monitoring of the nutrient solutions, for the monitoring of the soil salinity, for the quality control, and for many other applications, with features such as the automatic calibration and the data logging; the electrical conductivity tester is an essential instrument for the conductivity measurement. Electrical conductivity testers are used in the water treatment, in the agriculture and the hydroponics, in the environmental monitoring, in the laboratories, in the food and the beverage industry, and for many other applications. With their conductivity measurement, electrical conductivity testers are essential for the quality assessment.

Electrical Conductivity Tester LECT-T2010

Electrical Conductivity Tester LECT-T2010



Electrical Conductivity Tester can measure conductivity across a wide range from 1 to 19,999 pS/m. It delivers accurate readings with a measurement accuracy of ± (2% + 2 pS), ensuring r...

Standards

USP General Chapter <645>-Water Conductivity

IEC 60746-3:2002-Expression of performance of electrochemical analyzers-Part 3: Electrolytic conductivity

Complies with the above standards, but is not limited to them.

Features

1. Electrical conductivity tester for measuring conductivity of solutions to determine ionic concentration and purity.

2. Portable or benchtop conductivity meter with conductivity cell (K=0.1, 1, 10) and automatic temperature compensation.

3. Suitable for water treatment, environmental, hydroponics, aquaculture, industrial process and educational applications.

4. Includes tester body, conductivity probe, calibration solutions, batteries/power, and operation manual.

5. Supports conductivity (microS/cm, mS/cm), TDS (ppm), salinity (ppt) and temperature measurement of aqueous solutions.

FAQ

Q1: What testing scenarios is this tester mainly applied to?

A: The electrical conductivity tester is used in water treatment, environmental monitoring, hydroponics, aquaculture, industrial process, and educational settings to measure the electrical conductivity of aqueous solutions, which indicates the concentration of dissolved ions (salts, minerals) and serves as an indicator of water purity, salinity, and contamination. It supports water treatment (drinking water (conductivity as indicator of dissolved solids, treatment efficiency, RO/DI system performance; typical drinking water 50-800 microS/cm; distilled/DI <1 microS/cm; UPW <0.056 microS/cm at 25 C), wastewater (influent/effluent conductivity - process control, discharge monitoring, industrial discharge (high conductivity from salts/acids)), RO/DI system monitoring (conductivity increases as membrane degrades or resin exhausts; quick QC), boiler/cooling water (conductivity for blowdown control, corrosion/scale monitoring), environmental (rivers, lakes, groundwater, estuaries, seawater (conductivity/salinity - ecological monitoring, pollution detection (industrial discharge increases conductivity), stormwater), hydroponics/aquaculture (nutrient solution conductivity (EC in mS/cm or CF - controls fertilizer concentration; typical hydroponic EC 1-3 mS/cm depending on crop/stage; aquaculture water quality (salinity for marine fish, conductivity for freshwater), industrial process (plating baths (conductivity of electrolyte, metal concentration), cleaning solutions (CIP concentration), chemical manufacturing, power plant water (high-purity water monitoring), food/beverage (water quality, product concentration, cleaning validation), and education/research (chemistry labs, water quality experiments, teaching). Conductivity measurement principle: Two (or four) electrodes in solution apply AC voltage; current flow is proportional to ion concentration. Conductivity (G) = 1/R (resistance). Specific conductivity (kappa) = G x cell constant (K = distance/area), units S/m or microS/cm. Pure water has very low conductivity (~0.055 microS/cm at 25 C theoretically); adding ions increases conductivity. Temperature strongly affects conductivity (ions move faster at higher temp; typical 2%/degree C for aqueous solutions) - automatic temperature compensation (ATC) normalizes to 25 C. Conductivity is non-specific (measures total ions, not individual ions) - cannot identify which ions are present. TDS (total dissolved solids) is estimated from conductivity using a conversion factor (typically 0.5-0.7, depends on ion type): TDS (mg/L) = conductivity (microS/cm) x factor. Salinity can be calculated from conductivity (for seawater, using practical salinity scale). This is a general "tester" (may be portable pen-type or basic benchtop) - simpler than a full lab conductivity meter but serves same measurement purpose.

Q2: What standards does the tester comply with?

A: The electrical conductivity tester follows relevant ISO, ASTM, EPA and GB/T standards including ISO 7888 (water quality - determination of electrical conductivity), ASTM D1125 (standard test methods for electrical conductivity and resistivity of water), ASTM D5494 (standard test methods for electrical conductivity of water? actually ASTM D1125 is primary), EPA Method 120.1 (conductivity), USP <645> (water conductivity - for pharmaceutical water, though this requires specific uncompensated measurement), and GB/T standards for conductivity meters. The hardware complies with applicable accuracy standards (typically +/- 1-2% full scale, resolution 0.1 microS/cm to 0.1 mS/cm depending on range), ATC (automatic temperature compensation to 25 C, typically 2%/C linear or non-linear for seawater), and EMC/safety (IEC 61326, IEC 61010 for benchtop; IP rating for portable). Calibration uses certified conductivity standards (KCl solutions: 1413 microS/cm, 12.88 mS/cm, 111.3 mS/cm at 25 C, traceable to national standards) per ISO 7888/ASTM D1125. For pharmaceutical water (PW, WFI), follow USP <645> which requires stage 1 (uncompensated conductivity at measured temp, compare to table) - ATC may not be used for stage 1; use a meter that can display raw conductivity at temperature. For hydroponics, follow standard horticultural practices (EC in mS/cm or CF; 1 CF = 0.1 mS/cm = 100 microS/cm). For aquaculture/seawater, follow practical salinity scale (PSS-78) which uses conductivity ratio. For regulated labs (ISO 17025), maintain calibration records (calibration certificates, standard lot, as-found/as-left data, cell constant verification).

Q3: What is the warranty period for the whole tester and key components?

A: The whole electrical conductivity tester is covered by a 12-24 month warranty (analytical instruments often 1-2 years; portable pens 1 year). The meter body, electronics, display, and temperature sensor are covered, while conductivity probe/cell (wear part - electrodes can foul/platinize (platinum black wears off), cell constant drifts; replaceable), calibration solutions (consumable - expire, absorb CO2), and batteries (portable - wear) are consumables/accessories. Damage from improper use, probe fouling (scale, biofilm, protein - clean regularly; plating baths can deposit metals on electrodes), dry storage (some cells need wet storage? Most conductivity cells can be stored dry; but polarized cells may need conditioning), dropping (portable units), liquid ingress into meter (pen testers are often IP67 but not fully submersible head), using wrong cell constant for sample (K=0.1 for pure water, K=1 for general, K=10 for high conductivity; wrong cell gives out-of-range/inaccurate), or unauthorized repair is excluded. Extended warranty may be available. Electronics last 3-7 years; conductivity probe lasts 1-5 years depending on use/fouling (platinized cells need replating when response slows); batteries 1-3 years.

Q4: Is this device difficult to operate? Is professional training required?

A: Operation is very simple for basic measurement (rinse probe, immerse in sample, read). No professional training required. We provide operation manuals. Proper setup (insert batteries/connect power, turn on, allow warm-up (1-5 min), connect probe (if separate), prepare calibration (use certified KCl standard at measurement temperature; select appropriate standard for range: 1413 microS/cm for low/general, 12.88 mS/cm for medium, 111.3 mS/cm for high; for best accuracy, calibrate with standard close to expected sample conductivity), calibration (rinse probe with DI then standard, immerse in standard (ensure electrodes fully submerged, no air bubbles), stir gently, wait for stable reading (30-60 sec), confirm calibration (meter auto-detects common standards or enter value); for multi-point: calibrate at 2-3 points spanning range; single-point is common for routine use), sample measurement (rinse probe with DI then sample water (avoid carryover), immerse in sample (fully submerge electrodes, no air bubbles), stir gently or move probe (for consistent reading; conductivity cells need some flow to stabilize), wait for stable reading (30-60 sec), read conductivity (microS/cm or mS/cm) and/or TDS (ppm) / salinity (ppt) / temperature, for very low conductivity (pure water <10 microS/cm): use flow-through cell or constant stirring; pure water is sensitive to CO2 absorption (measure quickly, use fresh sample; atmospheric CO2 dissolves and increases conductivity to ~1 microS/cm), for high conductivity (seawater ~50 mS/cm, plating baths): use K=10 cell or dilute; ensure meter range covers sample), post-measurement (rinse probe thoroughly with DI water (remove sample residue), clean if fouled (general: DI rinse; scale: soak in mild acid (vinegar, 0.1 M HCl) then rinse; oil/grease: mild detergent or methanol; do NOT use abrasive on electrodes (damages platinum black); do NOT use strong oxidizers (bleach) on platinized cells), store probe (most cells store dry; some recommend storage in DI or KCl - follow manufacturer; never store in distilled water long-term? Actually conductivity cells are fine dry; polarized cells may need reconditioning), maintenance (daily: rinse after use, check calibration; weekly: clean probe (if industrial/wastewater - high fouling), inspect electrode (platinum black intact, no damage); monthly: full calibration, replace batteries (portable), cell constant verification; semi-annually/annually: professional calibration, probe replating (if platinized and worn), troubleshooting (readings unstable/drifting (probe fouled (clean), air bubbles on electrodes (remove), low battery, temperature fluctuation, sample not homogeneous (stir), CO2 absorption (pure water - measure quickly) - clean, remove bubbles, charge battery, control temp, measure fast), readings too high (calibration error (wrong standard, temp mismatch), probe not rinsed (carryover from previous high sample), cell constant wrong (select correct K), TDS conversion factor wrong (TDS = conductivity x factor; factor 0.5-0.7 depends on ion type; for NaCl ~0.5, for mixed salts ~0.65-0.7), ATC off (compare at same temp) - recalibrate, rinse, set cell constant, use correct TDS factor, enable ATC), readings too low (probe not fully submerged, air bubbles, cell constant too high (use K=0.1 for pure water), electrode fouled/plating worn (clean/replate), calibration at wrong range - submerge, remove bubbles, use correct cell, clean/replate, recalibrate), meter not reading (battery dead (portable), probe disconnected/cable fault, electrode failed, power issue - replace batteries, check cable, replace probe, service), and safety (ELECTRICAL (portable near water - check IP rating; do not immerse meter body (only probe); battery-powered is safer than mains; do not use with wet hands), CHEMICAL (calibration standards (KCl - low hazard, but avoid ingestion/eye contact; wear PPE), cleaning solutions (HCl, detergents - handle per SDS), samples (wastewater, chemicals, plating baths (acids, metal salts) - wear gloves, eye protection; some plating solutions are toxic (cyanide, hexavalent chromium) - handle with care), WATER PURITY (for pure water/UPW: use proper technique (flow-through, fresh sample, avoid CO2); conductivity of pure water is extremely low and sensitive), do not use wrong cell constant (K=1 for pure water gives noisy/low readings; use K=0.1; K=0.1 for high conductivity gives out-of-range), do not store platinized probe dry for long (may need reconditioning: soak in KCl or apply voltage; follow manufacturer), for hydroponics: EC reading is total ions, not specific nutrients; cannot tell if N/P/K balance is correct (need tissue analysis or ion-specific meters), for seawater: use salinity mode (PSS-78) rather than TDS (TDS factor for seawater is different ~0.03? Actually seawater TDS ~35000 ppm, conductivity ~50 mS/cm, factor ~0.7; but salinity (ppt) is more standard), report temperature with conductivity (even with ATC, report raw and compensated; for USP <645>, use uncompensated)) are important for accurate conductivity measurement.

Q5: What is the typical lead-time for order delivery?

A: Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.

Q6: Is regular calibration required? What is the recommended calibration cycle?

A: Calibration recommended: single-point calibration before each use or at start of day (especially portable pens which drift); multi-point calibration (2-3 points) every 1-4 weeks or per quality system. If probe is cleaned/replaced, meter dropped, or readings seem off, recalibrate. Routine verification: check with a standard different from calibration standard periodically. For ISO 17025/commercial labs, follow applicable schedules and maintain records (calibration certificates, standard lot/expiry, as-found/as-left data, cell constant, user/operator). For hydroponics/aquaculture, calibrate weekly (frequent use, probes drift). For pure water/UPW monitoring, calibrate more frequently (low conductivity is hard to measure accurately; use fresh low-conductivity standard or verify with resistivity meter). Conductivity standards are stable (KCl solutions, sealed, traceable; once opened, use within period or prepare fresh - KCl absorbs moisture from air, so keep sealed). Cell constant should be verified annually (with certified standard) - if cell constant drifts >2%, clean or replace probe. Temperature sensor should be calibrated periodically (ATC accuracy depends on temp sensor).

Q7: Are supporting consumables universal?

A: Conductivity probe/cell (replacement - specific to meter brand/model (connector type, cell constant; use OEM or certified compatible with correct K value), calibration solutions (KCl standards - universal from lab supply (Hanna, Hach, Oakton, Ricca) but use certified traceable; 1413 microS/cm, 12.88 mS/cm, 111.3 mS/cm common), batteries (standard AA/AAA/9V - universal for portable), and cleaning supplies are available from water quality/lab supply companies, though probes are often meter-specific (use OEM or certified compatible with correct cell constant and connector to maintain accuracy and warranty). Long-term consumable cost includes probe replacement (periodic, $50-$300) and calibration solutions (regular purchase, low cost).

Q8: Can I customize parameters or supporting accessories?

A: Customization includes type (portable pen/tester (battery, waterproof IP67, one-handed, field use) or benchtop (lab, higher accuracy, more features, power supply)), cell constant (K=0.1 (for pure water/UPW, low conductivity <100 microS/cm), K=1 (general, 10 microS/cm to 200 mS/cm, most common), K=10 (for high conductivity, seawater, plating baths, >100 mS/cm)), parameters (conductivity only, or conductivity + TDS + salinity + temperature + resistivity (for pure water)), range (auto-ranging or manual; 0-200 microS/cm to 0-200 mS/cm), display/interface (basic (LCD, single range) or advanced (backlit, multi-parameter, data logging (100-1000 points), USB/Bluetooth export, PC software, GLP/GMP (calibration records, user ID), alarms, auto-hold, multi-language)), probe (integrated (pen) or separate (benchtop, with cable; glass or epoxy body; platinum black or graphite electrodes; 2-electrode or 4-electrode (4-electrode better for high conductivity, less polarization)), accessories (extra probe (different cell constant), calibration solution kit (multiple values), storage solution, cleaning solutions, probe stand (benchtop), spare batteries, carrying case (field), calibration certificate (ISO 17025), certifications (CE, FCC, ISO 9001, IP67), language and accessories. Additional probes, solutions, and accessories can be ordered separately.

Q9: Does the purchase include on-site installation and commissioning service?

A: Standard delivery includes electrical conductivity tester, conductivity probe, calibration solutions (initial), batteries/power cord, and instruction manual. On-site installation is not required for standard conductivity testers (unbox, calibrate, use - very simple). On-site training is not included for standard orders. Remote guidance provided. For high-purity water applications (pharmaceutical UPW) or industrial process integration: on-site setup/training can be arranged at additional cost. Always calibrate with certified standard before first use.

Q10: What types of samples are compatible with this equipment?

A: The electrical conductivity tester measures conductivity of various aqueous samples including drinking water, wastewater (influent/effluent), natural water (river, lake, groundwater, seawater), process water (industrial, cooling, boiler), hydroponic nutrient solution, aquaculture water, plating/electroplating baths, cleaning solutions (CIP), chemical solutions (acids, bases, salts - dilute), food/beverage liquids, and laboratory solutions. NOT compatible with: Non-aqueous liquids (oils, solvents, pure alcohol - conductivity is for aqueous/ionic; non-polar solvents have near-zero conductivity and may damage probe; some solvents can dissolve epoxy probe bodies), highly viscous samples without proper probe (can coat electrodes - clean promptly; dilute if needed), samples with high oil/grease (coats electrodes, causes drift - clean thoroughly; may damage epoxy), samples that attack probe materials (verify compatibility of electrode (platinum, graphite) and body (epoxy, glass) with sample; HF etches glass; strong solvents may attack epoxy; use appropriate probe), samples beyond meter range (very high conductivity >200 mS/cm (concentrated acids, brine) - use K=10 cell or dilute; very low <0.1 microS/cm (UPW) - use K=0.1 flow-through cell and specialized meter), and samples requiring specific ion identification (conductivity measures total ions, not individual species - use ion chromatography or ISE for specific ions). For samples with suspended solids: particles do not contribute to conductivity (unless ionic), but can foul probe - filter if needed or clean after. For hydroponic nutrient solutions: conductivity (EC) indicates total nutrient concentration but not N/P/K balance - combine with pH and periodic nutrient analysis. IMPORTANT: Electrical conductivity tester fundamentals: (1) What is conductivity? Conductivity (kappa, specific conductance) = ability of solution to conduct electric current. Units: S/m (SI) or microS/cm (common; 1 S/m = 10000 microS/cm). Resistivity = 1/conductivity, units ohm-cm or MOhm-cm (used for pure water; 18.2 MOhm-cm = 0.055 microS/cm = theoretical pure water at 25 C). Conductivity is non-specific: measures total dissolved ions (cations + anions), not individual species. (2) Typical conductivity values: - Ultra-pure water (UPW): 0.055 microS/cm (theoretical at 25 C) - Distilled/DI water: 0.5-2 microS/cm - Rainwater: 5-30 microS/cm - Drinking water: 50-800 microS/cm (US avg ~300) - River water: 50-1500 microS/cm - Groundwater: 100-5000 microS/cm - Wastewater effluent: 500-3000 microS/cm - Hydroponic nutrient: 1000-3000 microS/cm (1-3 mS/cm) - Seawater: ~50000 microS/cm (50 mS/cm) - Brine/concentrated salt: 100-300 mS/cm - Concentrated acids: >500 mS/cm (3) How conductivity meter works: - 2-electrode cell: Two plates apply AC voltage; measure current; conductivity = current/voltage x cell constant. Cell constant K = distance between electrodes / electrode area (cm^-1). - 4-electrode cell: Two outer electrodes apply current, two inner measure voltage; less affected by polarization, better for high conductivity. - AC voltage (not DC) to prevent polarization (ion buildup at electrodes) and electrolysis. - Platinum black coating on electrodes increases effective surface area, reduces polarization. - Cell constant: K=0.1 (large electrodes, close - for low conductivity/pure water), K=1 (general), K=10 (small electrodes, far - for high conductivity). (4) Temperature effect: - Conductivity increases with temperature (ions move faster; viscosity decreases). - Typical aqueous solutions: ~2% per degree C. - ATC (automatic temperature compensation): normalizes reading to 25 C using linear (2%/C) or non-linear (for seawater, natural water) algorithm. - Always report temperature and whether reading is compensated or raw. - For pharmaceutical water (USP <645>): Stage 1 uses UNCOMPENSATED conductivity at measured temperature (compare to USP table) - do not use ATC for this stage. (5) TDS and salinity: - TDS (total dissolved solids, mg/L or ppm) = conductivity (microS/cm) x conversion factor. Factor depends on ion composition: NaCl ~0.5, typical mixed salts ~0.65-0.7, KCl ~0.5. Meters use default factor (often 0.5 or 0.65) - may not match sample exactly. TDS is an estimate, not direct measurement. - Salinity (ppt or PSU): For seawater, calculated from conductivity using Practical Salinity Scale 1978 (PSS-78), which accounts for temperature and conductivity ratio. More accurate than TDS for seawater. (6) Common errors: - Wrong cell constant (K=1 for pure water = noisy/low; K=0.1 for high conductivity = out of range). - Not calibrating (drift; calibrate with standard close to sample range). - Air bubbles on electrodes (insulate, cause low/unstable readings - tap/remove). - Probe fouling (scale, biofilm, oil - clean regularly). - Temperature (ATC off or wrong; compare readings at same temp). - CO2 absorption (pure water absorbs atmospheric CO2 -> conductivity increases to ~1 microS/cm; measure quickly, use fresh sample, flow-through). - Carryover (not rinsing between samples, especially high to low). - TDS conversion factor (default factor may not match sample ion composition; for accurate TDS, use gravimetric method (filter, dry, weigh) or verify factor). - Using DC or old meter (polarization; use AC meters). - Not fully submerging electrodes (incomplete circuit = low reading). - For hydroponics: EC does not indicate nutrient balance (only total ions); over-fertilization shows high EC but may be wrong ratio. (7) Conductivity vs TDS vs salinity: - Conductivity: Direct measurement, units microS/cm, most fundamental. - TDS: Estimated from conductivity x factor, units mg/L, approximate. - Salinity: For seawater/brackish, calculated from conductivity (PSS-78), units ppt/PSU. - Report the appropriate parameter for application: water treatment = conductivity; hydroponics = EC (mS/cm) or TDS (ppm, but note factor); aquaculture/marine = salinity (ppt). (8) Choosing the right tester: - Pure water/UPW (pharmaceutical, semiconductor): K=0.1 cell, benchtop, resistivity display, USP <645> compatible, flow-through. - General water (drinking, environmental, wastewater): K=1 cell, portable or benchtop, ATC, TDS mode. - Hydroponics: K=1, portable, EC (mS/cm) display, waterproof, affordable pen. - Seawater/aquaculture: K=1 or K=10, salinity mode (PSS-78), temperature compensation. - High conductivity (plating, brine): K=10 cell, 4-electrode, high range. - Field/portable: Pen-type, waterproof IP67, battery, one-handed. - Lab/high accuracy: Benchtop, separate probe, multi-point calibration, data logging, GLP.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.

Inquiry