Introduction
A solvent moisture meter is an instrument used to measure the moisture content of the solvents and the other liquids, and it is used in the chemical, the pharmaceutical, the food, and the many other industries for the quality control and the process monitoring. The solvent moisture meter measures the moisture content by the Karl Fischer titration method, which is a chemical method in which the water in the sample reacts with the Karl Fischer reagent, and the amount of the reagent consumed is proportional to the water content, or by the other methods, such as the coulometric and the volumetric methods, and it provides the moisture content, expressed in parts per million or in percent, with a high accuracy and a low detection limit; the solvent moisture meter consists of a titration cell or a reaction vessel, the reagent and the solvent delivery system, a detection system, and a control and a display unit, and it performs the measurement automatically, with features such as the automated titration, the data logging, and the calculation of the results; the solvent moisture meter is used for the measurement of the moisture in the organic solvents, in the oils, in the pharmaceutical products, in the food products, and in the many other samples, for the quality control, for the verification of the dryness, for the process monitoring, and for many other applications. Solvent moisture meters are used in the chemical industry, in the pharmaceutical industry, in the food industry, in the petroleum industry, and for many other applications. With their moisture measurement, solvent moisture meters are essential for the quality control.
Solvent Moisture Meter LSMM-T2010
Solvent Moisture Meter utilizes Karl Fischer’s volumetric titration method and has a measurement range of 0.001% to 100%. It features a large, color measurement data enhances analysis e...
Standards
Complies with the above standards, but is not limited to them.
Features
1. Solvent moisture meter for water in solvents.
2. Meter measuring water content in solvents.
3. For chemical and pharmaceutical solvents.
4. Includes meter, cells, reagents and manual.
5. Measures trace water in solvents.
FAQ
Q1: What scenarios is this meter used for?
A: It measures trace water in chemical and pharmaceutical solvents by Karl Fischer or compatible methods to verify dryness.
Q2: What standards does it comply with?
A: It follows ISO 760, ASTM E203 and related GB/T standards, with calibration using standards. We confirm the stated performance during final inspection and can supply a certificate of conformity together with supporting documents for audit purposes.
Q3: What is the warranty?
A: It carries a 12 to 24 month warranty covering the meter. Reagents are consumables. Damage from spills or misuse is excluded.
Q4: Is it hard to operate?
A: It requires trained staff for reagents, sealing and drift. We provide a manual and training.
Q5: What is the lead time?
A: Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.
Q6: Is calibration required?
A: Performance should be verified periodically using calibrated reference standards, with results logged in the equipment record. Most users perform this check every 6 to 12 months or according to their internal quality schedule. We provide the procedure, reference materials and formal calibration service if required.
Q7: Are consumables universal?
A: These are disposable consumables and should be replaced after use to avoid cross-contamination. They are standard laboratory items available directly from us or from general laboratory suppliers, which keeps running costs low. We recommend keeping a small stock, and bulk pricing is available for regular orders.
Q8: Can it be customized?
A: Yes, several configurations are available. Options include volumetric or coulometric modes and data systems. We can discuss further custom requirements, confirm feasibility and advise any effect on the schedule before the order is confirmed.
Q9: Is installation included?
A: The instrument does not need professional installation. After unpacking, connect it to the specified power supply, allow it to stabilize and confirm the self-check passes. The package includes a printed manual, and our support team offers remote assistance throughout setup.
Q10: What samples are compatible?
A: It handles solvents that dissolve or release water in the medium within range. It is not for samples that react with the reagents, non-compatible matrices, or water beyond range.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.