Introduction

A dry block temperature calibrator is a temperature calibrator in which the temperature sensor is inserted into a heated or a cooled metal block, and it is used for the calibration of the temperature sensors and the instruments, such as the thermocouples, the RTDs, and the thermistors, in the industry, the laboratories, and the field. The dry block calibrator consists of a metal block with the wells of the different sizes and depths, a heating and a cooling system, a temperature control system, a display, and, in some models, a reference thermometer, and it provides a controlled and a stable temperature in the wells, into which the sensors are inserted; the sensor is inserted into the well, and the calibrator measures the output of the sensor at the reference temperature, which is provided by the calibrator and verified by the reference thermometer, and the calibration is performed by the comparison of the readings; the dry block calibrator provides a fast heating and cooling, a stable temperature, and a convenient operation, and it is portable and suitable for the field calibration, and it is available in various temperature ranges, from the low-temperature models to the high-temperature models, with features such as the programmable temperature profiles and the data logging; the dry block temperature calibrator is used for the calibration of the temperature sensors in the process industry, for the verification of the instruments, for the quality control, and for many other applications. Dry block temperature calibrators are used in the process industry, in the laboratories, in the calibration services, in the field service, and for many other applications. With their convenient calibration, dry block temperature calibrators are essential for the temperature sensor calibration.

Portable Dry-lock Temperature Calibrator LPDTC-T2011

Portable Dry-lock Temperature Calibrator LPDTC-T2011



Portable Dry-Block Temperature Calibrator delivers a temperature range from 33°C to 660°C. It features a display resolution of 0.001°C for precise measurements. Integrated temperature...
Portable Dry-T20lock Temperature Calibrator LPDTC-T2010

Portable Dry-T20lock Temperature Calibrator LPDTC-T2010



Portable Dry-Block Temperature Calibrator operates within a range of -25°C to 150°C for accurate calibration. It maintains temperature stability of ≤±0.05°C per 15 minutes, ensuring...

Standards

IEC 60751:2008-Industrial platinum resistance thermometers and platinum temperature sensors

EURAMET Calibration Guide cg-13-Guidelines on the Calibration of Temperature Block Calibrators

Complies with the above standards, but is not limited to them.

Features

1. Dry block temperature calibrator for calibrating temperature sensors.

2. Portable dry well with heated and cooled blocks and reference input.

3. For process, industrial and laboratory temperature calibration.

4. Includes calibrator, inserts, reference sensor and manual.

5. Provides stable dry block temperatures for sensor comparison.

FAQ

Q1: What scenarios is this calibrator used for?

A: It calibrates thermocouples, RTDs and temperature switches by inserting them into a heated or cooled metal block alongside a reference sensor, providing stable setpoints for comparison in process and industrial maintenance.

Q2: What standards does it comply with?

A: It follows IEC 60751 for RTDs, IEC 60584 for thermocouples, EA-10/11 guidance and related GB/T standards, with the reference sensor traceable and block uniformity verified.

Q3: What is the warranty?

A: The calibrator carries a 12 to 24 month warranty covering the unit and controls. Inserts and batteries are consumables or wear parts. Damage from over-temperature or unauthorized repair is excluded.

Q4: Is it hard to operate?

A: Operation requires trained calibration staff to select setpoints, insert sensors and calculate errors. We provide a manual, installation and training.

Q5: What is the lead time?

A: Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.

Q6: Is calibration required?

A: The reference sensor and block must be calibrated annually or per quality schedule with traceable standards. Keep certificates and as-found/as-left records.

Q7: Are consumables universal?

A: Inserts are model-specific and drilled for sensors, while reference sensors are certified. Ongoing cost includes inserts and periodic reference calibration.

Q8: Can it be customized?

A: Yes, several configurations are available. Options include heating and cooling range, block size, reference input, multi-function readout, data logging and field cases. We can discuss further custom requirements, confirm feasibility and advise any effect on the schedule before the order is confirmed.

Q9: Is installation included?

A: Standard delivery includes the calibrator, inserts and manual. Installation is not required, with training available.

Q10: What devices are compatible?

A: It calibrates sensors that fit the inserts within the temperature range. It is not for sensors too large for the block, liquid-filled systems, or temperatures beyond the rated range.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.

Inquiry