Introduction
A standard analytical balance is a high-precision laboratory balance used for weighing small masses with high accuracy, and it is one of the most important instruments in analytical chemistry, pharmaceutical, and research laboratories. The standard analytical balance measures the mass of the sample by an electromagnetic force compensation mechanism, in which the sample is placed on the weighing pan, and the balance applies an electromagnetic force to balance the weight of the sample, and the force is converted to a mass reading, which is displayed digitally; the analytical balance provides a high readability, typically 0.1 milligram, and a high accuracy and precision, and it is used in a draft shield with sliding doors to protect the weighing from air currents, and it is calibrated with standard weights, and it provides features such as tare, units conversion, internal or external calibration, and a level indicator, and it is used on a stable, vibration-free surface, and it requires careful handling, such as closing the draft shield doors during the weighing and allowing the reading to stabilize; the standard analytical balance is available in various capacities, typically up to 200-300 grams. Standard analytical balances are used for weighing samples and reagents for analysis, for preparing standard solutions, for weighing for gravimetric analysis, for weighing drug substances in pharmaceutical laboratories, for quality control, for research, for education, and for many other applications. With their high accuracy, standard analytical balances are essential instruments for precise weighing in the laboratory.
Standard Analytical Balance LSAB-T2030
Standard Analytical Balance offers a capacity of 100 g or 600 g, with a minimum weighing precision of 0.004 g and 0.04 g, ensuring accurate measurements across a wide range of applicatio...
Standard Analytical Balance LSAB-T2021
Standard Analytical Balance is a portable standard high speed analytical weighing balance. Built-in magnetic sensor for faster weighing with stability. Equipped with a weighing capacity ...
Standard Analytical Balance LSAB-T2010
Standard Analytical Balance is a portable standard high speed analytical weighing balance. Built-in magnetic sensor for faster weighing with stability. Equipped with a weighing capacity ...
Standard Analytical Balance LSAB-T2020
Standard Analytical Balance is a portable standard high speed analytical weighing balance. Built-in magnetic sensor for faster weighing with stability. Equipped with a weighing capacity ...
Standards
OIML R 76-1:2006-Non-automatic weighing instruments-Part 1: Metrological and technical requirements
Complies with the above standards, but is not limited to them.
Features
1. Standard analytical balance for routine precise weighing.
2. Analytical balance with draft shield and digital display.
3. For general laboratory analytical weighing.
4. Includes balance, draft shield, adapter and manual.
5. Provides accurate mass measurement.
FAQ
Q1: What scenarios is this balance used for?
A: It performs routine analytical weighing with a draft shield for stable readings in general laboratory work. Customers in related industries rely on it for routine and quality-control work, and we can match the unit to your intended use.
Q2: What standards does it comply with?
A: It follows OIML R76 or equivalent metrology and GB/T standards, with calibration traceable. The relevant parameters are verified during final inspection before shipment, and compliance documentation or test reports can be provided on request for your quality records.
Q3: What is the warranty?
A: The balance carries a 12 to 24 month warranty covering load cell and display. Damage from overload or spills is excluded.
Q4: Is it hard to operate?
A: Operation is simple after training: level, calibrate, tare and weigh. We provide a manual and training.
Q5: What is the lead time?
A: Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.
Q6: Is calibration required?
A: Performance should be verified periodically using calibrated reference standards, with results logged in the equipment record. Most users perform this check every 6 to 12 months or according to their internal quality schedule. We provide the procedure, reference materials and formal calibration service if required.
Q7: Are consumables universal?
A: These are disposable consumables and should be replaced after use to avoid cross-contamination. They are standard laboratory items available directly from us or from general laboratory suppliers, which keeps running costs low. We recommend keeping a small stock, and bulk pricing is available for regular orders.
Q8: Can it be customized?
A: Yes, several configurations are available. Options include capacity, readability, internal calibration and data output. We can discuss further custom requirements, confirm feasibility and advise any effect on the schedule before the order is confirmed.
Q9: Is installation included?
A: No installation is required. The unit is delivered fully assembled and factory tested, so you only need to place it on a level surface, connect power and follow the quick-start guide. An illustrated manual and setup video are included, and our engineers provide remote guidance if needed.
Q10: What samples are compatible?
A: It handles stable samples within capacity. It is not for heavy loads, samples in moving air, or vibrating environments beyond stability.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.




