Introduction
An electrolyte analyzer is a laboratory instrument used to measure the concentrations of electrolytes in biological samples, such as serum, plasma, urine, and whole blood, and it is used in clinical laboratories, hospitals, and point-of-care settings for the rapid measurement of sodium, potassium, chloride, calcium, and other electrolytes. The analyzer measures the electrolyte concentrations using ion-selective electrodes (ISE), in which each electrode is selective for a specific ion and develops an electrical potential that depends on the concentration of that ion in the sample; the sample is introduced into the analyzer, and the potentials of the electrodes are measured and converted to concentrations, with automatic calibration using standard solutions, and the analyzer provides rapid and accurate results, and it is available in various configurations, from small point-of-care analyzers for whole blood to larger analyzers for clinical laboratories, with features such as automatic sampling, quality control, and data management. Electrolyte analyzers are used in clinical laboratories and hospitals for measuring the electrolyte balance of patients, for diagnosing and monitoring conditions such as dehydration, kidney disease, and electrolyte disorders, for monitoring patients in intensive care and surgery, for testing in emergency settings, for research, in veterinary laboratories, and for many other applications, and they are used with other clinical chemistry tests as part of the routine blood testing. With their rapid and accurate measurement, electrolyte analyzers are essential instruments in clinical diagnostics.
Automatic Electrolyte Analyzer LAEA-T2010
Automatic Electrolyte Analyzer requires minimal sample volume (as low as 80μL) and delivers results within 25 seconds. It has an imported TCO₂ module for reliable performance and preci...
Automatic Electrolyte Analyzer LAEA-T2011
Automatic Electrolyte Analyzer test plasma, serum, whole blood, urine, and samples, measuring parameters such as K⁺, Na⁺, Cl⁻, Ca²⁺, pH, and TCO₂. It operates within a temperature ...
Portable Electrolyte Analyzer LPEA-T2012
Portable Electrolyte Analyzer has the capacity to store up to 5,000 sample records, with options for further data expansion. It functions optimally at temperatures between 5°C and 40°C...
Portable Electrolyte Analyzer LPEA-T2011
Portable Electrolyte Analyzer requires only a minimal sample volume of 90µL and delivers results in just 25 seconds. It supports plasma, serum, whole blood, urine, and samples, testing ...
Portable Electrolyte Analyzer LPEA-T2010
Portable Electrolyte Analyzer operates efficiently within an ambient temperature range of 5°C to 40°C and relative humidity up to 80%. It supports up to 5,000 sample data storage, with...
Semi-T20utomated Electrolyte Analyzer LSAE-T2018
Semi-Automated Electrolyte Analyzer allows for rapid testing, completing measurements in just 25 seconds. It requires a sample volume of 65 to 150µL for various sample types such as pla...
Automatic Electrolyte Analyzer LAEA-T2017
Automatic Electrolyte Analyzer features fast measuring cycle of under 25 seconds and a sample volume requirement of just 80µL. It can store over 10,000 results and has standard network ...
Semi-T20utomated Electrolyte Analyzer LSAE-T2017
Semi-Automated Electrolyte Analyzer requires a sample volume of 65 to 150 µL, with a resolution of 0.01 to 0.1 mmol/L depending on the parameter. It operates optimally between a tempera...
Semi-T20utomated Electrolyte Analyzer LSAE-T2015
Semi-Automated Electrolyte Analyzer features a sample loader with 25 to 40 positions, operates efficiently in ambient temperatures from 5°C to 40°C. It includes bar code scanning for e...
Semi-T20utomated Electrolyte Analyzer LSAE-T2016
Semi-Automated Electrolyte Analyzer test a variety of sample types like, plasma, serum, whole blood, urine, and across K⁺, Na⁺, Cl⁻, Ca²⁺, and pH parameters. Each test requires a sa...
Semi-T20utomated Electrolyte Analyzer LSAE-T2014
Semi-Automated Electrolyte Analyzer has a sample volume requirement of 65 to 150µL and a testing capacity of up to 60 samples per hour. The consumable management system supports over 20...
Semi-T20utomated Electrolyte Analyzer LSAE-T2013
Semi-Automated Electrolyte Analyzer can process up to 60 samples per hour, supporting both primary tubes and cuvettes. With rapid testing capability, completing tests in just 25 seconds,...
Semi-T20utomated Electrolyte Analyzer LSAE-T2011
Semi-Automated Electrolyte Analyzer supports sample volumes from 65 to 150 µL and processes up to 60 samples per hour. It provides precise measurement of K⁺, Na⁺, Cl⁻, and TCO₂ acro...
Semi-T20utomated Electrolyte Analyzer LSAE-T2012
Semi-Automated Electrolyte Analyzer offers precision in measuring K⁺, Na⁺, Cl⁻, and TCO₂ across a wide range in plasma, serum, whole blood, urine, and samples. It supports sample vol...
Automatic Electrolyte Analyzer LAEA-T2016
Automatic Electrolyte Analyzer measure parameters like K⁺, Na⁺, Cl⁻, Ca²⁺, fault alarms and troubleshooting support, making it easy to use. With a wide measuring range and impressiv...
Automatic Electrolyte Analyzer LAEA-T2015
Automatic Electrolyte Analyzer can test plasma, serum, whole blood, urine, and samples, measuring parameters such as K⁺, Na⁺, Cl⁻, Ca²⁺ and, pH. It operates within a temperature ran...
Automatic Electrolyte Analyzer LAEA-T2012
Automatic Electrolyte Analyzer features fast measurement cycle of less than 25 seconds requiring only 80μl of sample volume. It offers a user-friendly interface with online fault alarms...
Automatic Electrolyte Analyzer LAEA-T2013
Automatic Electrolyte Analyzer include the ability to test electrolytes like K⁺, Na⁺, and Cl⁻ in plasma, serum, whole blood, urine, and cerebrospinal fluid (). Its one-button maintena...
Automatic Electrolyte Analyzer LAEA-T2014
Automatic Electrolyte Analyzer is a 5-parameter analyzer requiring just 80μL of sample and deliver results in under 25 seconds. It offers a large storage capacity for over 10,000 result...
Automatic Electrolyte Analyzer LAEA-T2021
Automatic Electrolyte Analyzer processes a sample volume of 65μL and delivers results in approximately 30 seconds. It can store over 1,000 test results, allowing for a streamlined diagn...
Automatic Electrolyte Analyzer LAEA-T2020
Automatic Electrolyte Analyzer is a 3-parameter analyzer, testing potassium (K⁺), sodium (Na⁺), and chloride (Cl⁻), with high precision across a broad range. It requires a minimal sam...
Automatic Electrolyte Analyzer LAEA-T2011
Automatic Electrolyte Analyzer rapidly measures 5 electrolyte concentrations with only 100 µL of whole blood. Designed with latest dry electrochemical technology with exclusive molecula...
Automatic Electrolyte Analyzer LAEA-T2010
Automatic Electrolyte Analyzer offers an efficient and accurate analysis of electrolyte concentrations in biological samples during the diagnosis and management of electrolyte disorders....
Semi-T20utomated Electrolyte Analyzer LSAE-T2010
Semi-Automated Electrolyte Analyzer accurately measures K⁺, Na⁺, Cl⁻, Ca²⁺, error alerts and troubleshooting assistance, delivering a wide measurement range with high precision. Our...
Standards
IEC 61010-2-081:2015-Particular requirements for automatic and semi-automatic laboratory equipment for analysis and other purposes
Complies with the above standards, but is not limited to them.
Features
1. Electrolyte analyzer for measuring blood electrolytes (Na, K, Cl, Li, Ca).
2. Fully automated ion-selective electrode (ISE) analysis for clinical diagnostics.
3. Suitable for hospitals, clinical laboratories, emergency rooms and healthcare facilities.
4. Includes sample handling, ISE electrodes, reagents, controller, software and manual.
5. Supports rapid, accurate electrolyte measurement for clinical diagnosis and monitoring.
FAQ
Q1: What testing scenarios is this analyzer mainly applied to?
A: The electrolyte analyzer is used in hospitals, clinical laboratories, emergency rooms, intensive care units, outpatient clinics, healthcare facilities and research to measure blood electrolytes including sodium (Na), potassium (K), chloride (Cl), lithium (Li), ionized calcium (Ca) and sometimes bicarbonate (TCO2) in serum, plasma or whole blood for clinical diagnosis, patient monitoring and emergency care. It supports routine clinical electrolyte testing (metabolic panel), emergency room electrolyte measurement (critical care), ICU patient monitoring (electrolyte balance), kidney function assessment (Na, K, Cl), cardiac monitoring (K, Ca for arrhythmia risk), lithium therapy monitoring (psychiatric patients), and outpatient clinic routine testing. Electrolyte measurement is one of the most commonly ordered clinical tests, essential for assessing hydration, kidney function, acid-base balance and cardiac risk.
Q2: What standards does the analyzer comply with?
A: The electrolyte analyzer follows relevant ISO, IEC, CLSI and GB/T standards for in vitro diagnostic medical devices, including ISO 13485 for quality management, IEC 61010 for laboratory electrical safety, IEC 62304 for medical device software, CLSI guidelines for ISE methods, and applicable medical device regulations (FDA, CE, NMPA). The test follows relevant clinical laboratory standards (ISO 15189, CAP, CLIA). Calibration should use certified reference materials traceable to international standards. Users should verify regulatory approval status in their jurisdiction.
Q3: What is the warranty period for the whole analyzer and key components?
A: The whole electrolyte analyzer is covered by a 12-month warranty. The sample handling system, ISE electrodes, fluidics, controller, software and housing are covered, while electrodes, reagents, calibrators, tubing and fuses are consumables or accessories. Damage from improper use or unauthorized repair is excluded. Extended service contracts are standard for this clinical diagnostic equipment. ISE electrodes are wear items with typical lifespan of 6-12 months.
Q4: Is this device difficult to operate? Is professional training required?
A: Operation requires trained clinical laboratory personnel familiar with electrolyte testing, ISE technology and quality control. We provide comprehensive training, operation manuals and application support. Proper sample handling (serum, plasma, whole blood), calibration, quality control, electrode maintenance, reagent management, result interpretation (including critical values) and regulatory documentation are important for accurate, reliable clinical electrolyte testing.
Q5: What is the typical lead-time for order delivery?
A: Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.
Q6: Is regular calibration required? What is the recommended calibration cycle?
A: Calibration with certified calibrators recommended per schedule (typically daily or per reagent lot). Quality control (normal and abnormal levels) per day or per batch for clinical use. ISE electrode condition and slope verified periodically. Routine maintenance (electrode cleaning, fluidics) per schedule. Full system performance verification annually. Software updates and data integrity checks per regulatory requirements. Reagent lot verification per new lot.
Q7: Are supporting consumables universal?
A: ISE electrodes (Na, K, Cl, Li, Ca), reagents, calibrators, quality control materials, tubing, sample cups and cleaning supplies are available from the manufacturer or authorized distributors, though reagents and electrodes are typically proprietary to the system. Long-term consumable cost depends on test volume and reagent/electrode pricing.
Q8: Can I customize parameters or supporting accessories?
A: Customization includes test menu (Na, K, Cl, Li, Ca, TCO2 combinations), throughput (samples per hour), automation level (standalone, integrated with LIS), sample type (serum, plasma, whole blood, urine), software features (data management, LIS connectivity, 21 CFR Part 11), connectivity and accessories. Additional electrodes, reagent kits and accessories can be ordered separately. Custom orders extend delivery lead-time and may require regulatory re-approval.
Q9: Does the purchase include on-site installation and commissioning service?
A: Yes, electrolyte analyzers include on-site installation, commissioning, calibration, validation support and operator training by certified clinical diagnostic specialists. Site preparation guidance is provided before delivery.
Q10: What types of samples are compatible with this equipment?
A: The electrolyte analyzer measures electrolytes in serum, plasma (heparin, EDTA), whole blood and sometimes urine within the sample type, analyte range and specification. Different analytes have different reference ranges and clinical significance. Hemolysis can falsely elevate potassium (K) - samples should be inspected for hemolysis. Users should use proper sample collection tubes (serum separator tube for serum, heparin tube for plasma), avoid hemolysis (critical for K measurement), process samples promptly (electrolytes are relatively stable but should be analyzed within recommended time), calibrate per schedule with certified calibrators, run quality control (normal and abnormal) per day, verify ISE electrode slope per maintenance schedule, follow proper result interpretation (reference ranges, critical values, delta checks), report results in mmol/L (or mEq/L) with sample type and method specified, and for clinical use, follow validated methods and regulatory requirements (CLIA, CAP, ISO 15189). The analyzer should be maintained per manufacturer schedule (electrode cleaning, fluidics maintenance, deproteinization). ISE electrodes should be replaced when slope degrades or response time increases. For whole blood testing, use proper anticoagulant (heparin preferred, EDTA may interfere with some analytes). For lithium testing, note that lithium heparin tubes can interfere (use serum or other anticoagulant). The analyzer should have proper data management and LIS connectivity for clinical use. Critical values (e.g., K <2.5 or >6.0 mmol/L, Na <120 or >160 mmol/L) should have alert systems and proper clinical notification procedures. Waste (reagents, samples) should be disposed of per biohazard and chemical waste regulations. The analyzer should be placed in a temperature-controlled environment (15-30 degrees C typical). For point-of-care use, ensure proper training and quality assurance programs (POCT regulations).
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.