Introduction
A multi automated stainer is an automated staining instrument designed for the staining of the slides with the multiple staining protocols, and it is used in the pathology, the histology, the clinical, and the many other applications. The multi automated stainer performs the multiple staining protocols automatically, such as the hematoxylin and the eosin (H&E) staining, the special staining, and the immunohistochemistry (IHC) staining, and it processes the multiple slides in the batches, with the consistent and the reproducible staining; the multi automated stainer consists of the slide racks, the reagent containers, a fluid delivery system, the staining stations, a control system, and the display, and it provides features such as the programmable protocols; the multi automated stainer is used for the staining of the tissue sections for the histology, for the H&E and the special staining, for the IHC, for the pathology, and for many other applications, and it is an essential instrument in the histology laboratory. Multi automated stainers are used in the pathology, in the histology, in the clinical laboratories, in the research, and for many other applications. With their multiple staining protocols, multi automated stainers are essential for the versatile staining.
Multi Automated Stainer LMAS-T2010
Multi Automated Stainer supports Gram, Ziehl-Neelsen and Fluorescence staining with horizontal installation, processing 1 to 16 slides per cycle efficiently. Its integrated drying mechan...
Multi Automated Stainer LMAS-T2011
Multi Automated Stainer features vertical installation with an open lid height of 580mm for easy access. It Integrate color optimization function enhancing stain contrast for better visu...
Multi Automated Stainer LMAS-T2020
Multi Automated Stainer offers a high-throughput and flexible staining process with 3 in 1 solution - Ziehl-Neelsen, Kinyoun, and Fluorescence. A maximum of 10 to 20 slides can be staine...
Standards
ISO 15189:2022-Medical laboratories-Requirements for quality and competence
ISO/TS 23824:2024-Medical laboratories-Guidance on application of ISO 15189 in anatomic pathology
Complies with the above standards, but is not limited to them.
Features
1. Multi automated stainer for high-throughput multi-module slide staining.
2. Multiple independent staining modules for maximum throughput and flexibility.
3. Suitable for large pathology, histology, clinical and reference laboratories.
4. Includes multi-module staining system, reagent management, software and manual.
5. Supports high-volume automated staining with multiple simultaneous protocols.
FAQ
Q1: What testing scenarios is this stainer mainly applied to?
A: The multi automated stainer is used in large pathology laboratories, reference laboratories, hospital networks, clinical diagnostics, pharmaceutical development and research to perform high-throughput automated staining of tissue slides with multiple independent modules running different protocols simultaneously for histopathological diagnosis, clinical testing and research. It supports high-volume clinical pathology H&E and special stain processing, reference laboratory multi-protocol staining, pharmaceutical high-throughput tissue analysis, IHC and special stain parallel processing, and large-scale research staining. The multi-module design provides maximum throughput and flexibility, allowing many different staining protocols to run simultaneously, suitable for high-volume laboratories requiring efficient, consistent slide processing.
Q2: What standards does the stainer comply with?
A: The multi automated stainer complies with relevant IEC 61010 laboratory electrical safety standards, applicable GB/T standards for histological equipment, and relevant medical device regulations for clinical use. The instrument follows applicable electromagnetic compatibility standards. Reagents and stains should be from qualified suppliers. Users should verify compliance with specific facility requirements including biosafety and clinical laboratory accreditation (ISO 15189, CAP).
Q3: What is the warranty period for the whole machine and key components?
A: The whole multi automated stainer is covered by a 12-month warranty. The multi-module staining system, reagent management, controller, software and housing are covered, while reagents, slides, tubing and fuses are consumables. Damage from improper use, reagent spills or unauthorized repair is excluded. Extended service contracts are standard for this high-throughput clinical equipment.
Q4: Is this device difficult to operate? Is professional training required?
A: Operation requires trained histology or pathology personnel familiar with high-throughput automated staining and laboratory management. We provide comprehensive training, operation manuals and application support. Proper slide loading, reagent management, multi-module protocol programming, stain quality monitoring, workflow management and biosafety procedures are critical for efficient, consistent operation.
Q5: What is the typical lead-time for order delivery?
A: Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.
Q6: Is regular calibration required? What is the recommended calibration cycle?
A: Staining quality verification with control slides recommended per run per module for clinical use. Reagent level and condition checked per schedule. All modules verified independently. Software updates installed as needed. Full system performance verification annually. Routine cleaning of reagent stations and fluidics recommended.
Q7: Are supporting consumables universal?
A: Stains, reagents, slides, coverslips and tubing are available from histology suppliers, though instrument-specific parts should be verified. Long-term consumable cost depends on staining volume and reagent choices.
Q8: Can I customize parameters or supporting accessories?
A: Customization includes number of modules, per-module slide capacity, staining protocols, reagent management, IHC capability, LIS connectivity, software features and accessories. Additional reagent kits and accessories can be ordered separately. Custom orders extend delivery lead-time.
Q9: Does the purchase include on-site installation and commissioning service?
A: Yes, multi automated stainers include on-site installation, commissioning, protocol setup, LIS integration and operator training by certified specialists. Site preparation guidance is provided before delivery to ensure power, ventilation, IT and workflow requirements are met.
Q10: What types of slides are compatible with this equipment?
A: The multi automated stainer stains prepared tissue slides within each module capacity, protocol and reagent specification. Each module can run a different staining protocol independently. Different staining methods require specific reagents. Slides should be properly prepared and loaded with proper identification (barcode recommended for high-throughput). Users should implement proper slide tracking (barcode/LIS), load slides properly per module, use appropriate reagents, program correct protocols, include control slides per module, follow proper biosafety procedures, and maintain proper waste disposal. Each module should be cleaned regularly. For high-throughput clinical use, proper workflow management and result tracking should be established per laboratory accreditation requirements. The system should be integrated with LIS for result management and traceability.